ECG data compression using cut and align beats approach and 2-D transforms
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
A new electrocardiogram (ECG) data compression method is presented which employs a two dimensional (2-D) transform. This 2-D transform method utilizes the fact that ECG signals generally show two types of redundancies--between adjacent heartbeats and between adjacent samples. A heartbeat data sequence is cut and beat-aligned to form a 2-D data array. Any 2-D compression method can then be applied. Transform coding using the 2-D discrete cosine transform (DCT) [2-D DCT] is employed here as an example. Using selections from the MIT-BIH arrhythmia and Medtronic databases, results are presented that illustrate substantial improvement in compression ratio over one-dimensional methods for comparable percent root-mean-square difference (PRD).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“For example, this detection can be based on bandpass and matched filtering followed by threshold detection [22].”
MethodNo, P. (1986) · Cited by 1,532
Barratt, K. H. (1985) · Electronics and Power · doi:10.1049/ep.1985.0201 · Cited by 1,523 · cited 2×
“As in [19], we assume is constant for all”
BackgroundMethodHawkes, P. W. (1978) · Nature · doi:10.1038/272740a0 · Cited by 827
ECG data compression techniques-a unified approach
Jalaleddine, S. M. S., Hutchens, C. G., Strattan, R. D., & Coberly, W. A. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52340 · Cited by 681 · cited 1×
“These can be divided into three major categories [ 3 ]: 1) direct methods (e.g., AZTEC [4], DPCM, TP [5], CORTES [4], SAPA, FAN), 2) transform methods (e.g., Fourier [6], Walsh [7], KLT [8], discrete cosine transform (DCT), wavelet [9], [10]), and 3) parameter extraction methods (e.g., linear prediction, long-term pre…”
BackgroundThe MIT-BIH Arrhythmia Database on CD-ROM and software for use with it
Moody, G. B., & Mark, R. G. (2002) · [1990] Proceedings Computers in Cardiology · doi:10.1109/cic.1990.144205 · Cited by 404 · cited 1×
“In Section V, results are presented based on samples from a MIT-BIH arrhythmia [16], [17] and Medtronic databases.”
MethodAZTEC, a Preprocessing Program for Real-Time ECG Rhythm Analysis
Cox, J. R., Nolle, F. M., Fozzard, H. A., & Oliver, G. C. (1968) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1968.4502549 · Cited by 367 · cited 2×
“These can be divided into three major categories [3]: 1) direct methods (e.g., AZTEC [4], DPCM, TP [5], CORTES [ 4 ], SAPA, FAN), 2) transform methods (e.g., Fourier [6], Walsh [7], KLT [8], discrete cosine transform (DCT), wavelet [9], [10]), and 3) parameter extraction methods (e.g., linear prediction, long-term pre…”
Wintz, P. A. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8780 · Cited by 288 · cited 1×
“This may slightly alter the realized average bit rate If we want a set bit rate, several reoptimization procedures are available [25], [26].”
BackgroundWavelet packet-based compression of single lead ECG
Bradie, B. D. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488797 · Cited by 119 · cited 1×
“, Fourier [6], Walsh [7], KLT [8], discrete cosine transform (DCT), wavelet [9], [10]), and 3) parameter extraction methods (e.”
MethodMultiwave: A Wavelet-Based ECG Data Compression Algorithm
Thakor, N. V., Sun, Y.-C., Rix, H., & Caminal, P. (1993) · HAL · Cited by 38
Cited by
Compressed Sensing: A Simple Deterministic Measurement Matrix and a Fast Recovery Algorithm
Ravelomanantsoa, A., Rabah, H., & Rouane, A. (2015) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2015.2459471 · Cited by 173
“It has also been used to compress the physiological signals such as EEG [27] or ECG [28].”
MethodHuang, H., Hu, S., & Sun, Y. (2019) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3341559 · Cited by 10
Metadata
- Authors
- Lee, H., & Buckley, K. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999-05
- Volume
- 46
- Issue
- 5
- Pages
- 556-564
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2145162005
- Cited by
- 160
- References
- 12
- FWCI
- 1.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.