CoChat

ECG data compression using cut and align beats approach and 2-D transforms

Hanwoo Lee, Buckley, K.M. · 1999 · IEEE Transactions on Biomedical Engineering
Cited by 160

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

A new electrocardiogram (ECG) data compression method is presented which employs a two dimensional (2-D) transform. This 2-D transform method utilizes the fact that ECG signals generally show two types of redundancies--between adjacent heartbeats and between adjacent samples. A heartbeat data sequence is cut and beat-aligned to form a 2-D data array. Any 2-D compression method can then be applied. Transform coding using the 2-D discrete cosine transform (DCT) [2-D DCT] is employed here as an example. Using selections from the MIT-BIH arrhythmia and Medtronic databases, results are presented that illustrate substantial improvement in compression ratio over one-dimensional methods for comparable percent root-mean-square difference (PRD).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.759056

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Lee, H., & Buckley, K. M.
Venue
IEEE Transactions on Biomedical Engineering
Published
1999-05
Volume
46
Issue
5
Pages
556-564
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2145162005
Cited by
160
References
12
FWCI
1.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.