Quantification of force abnormalities during passive and active-assisted upper-limb reaching movements in post-stroke hemiparesis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We evaluated a method for measuring abnormal upper-limb motor performance in post-stroke hemiparetic subjects. A servomechanism (MIME) moved the forearm in simple planar trajectories, directly controlling hand position and forearm orientation. Design specifications are presented, along with system performance data during an initial test of 13 stroke subjects with a wide range of impairment levels. Performance of subjects was quantified by measuring the forces and torques between the paretic limb and the servomechanism as the subjects relaxed (passive), or attempted to generate force in the direction of movement (active). During passive movements, the more severely impaired subjects resisted movement, producing higher levels of negative work than less-impaired subjects and neurologically normal controls. During active movements, the more severely impaired subjects produced forces with larger directional errors, and were less efficient in producing work. These metrics had significant test-retest repeatability. These motor performance metrics can potentially detect smaller within-subject changes than motor function scales. This method could complement currently used measurement tools for the evaluation of subjects during recovery from stroke, or during therapeutic interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance
Fugl-Meyer, A., Jääskö, L., Leyman, I., Olsson, S., & Steglind, S. (1975) · Journal of Rehabilitation Medicine · doi:10.2340/1650197771331 · Cited by 5,564
Cited by
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159
Movement Smoothness Changes during Stroke Recovery
Rohrer, B., Fasoli, S., Krebs, H. I., Hughes, R., Volpe, B., Frontera, W. R., Stein, J., & Hogan, N. (2002) · The Journal of Neuroscience · doi:10.1523/jneurosci.22-18-08297.2002 · Cited by 767
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Patton, J. L., Stoykov, M. E., Kovic, M., & Mussa-Ivaldi, F. A. (2006) · Experimental Brain Research · doi:10.1007/s00221-005-0097-8 · Cited by 469
“Studies using robotics for rehabilitation, assessment, and training have had some success (Krebs et al. 1998a; Lum et al. 1999).”
BackgroundLum, P. S., Burgar, C. G., Loos, M. V. D., Shor, P. C., Majmundar, M., & Yap, R. (2006) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2005.02.0044 · Cited by 461
Self-citationRobotics, Motor Learning, and Neurologic Recovery
Reinkensmeyer, D. J., Emken, J. L., & Cramer, S. C. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140223 · Cited by 415
Upper Limb Robot Mediated Stroke Therapy—GENTLE/s Approach
Loureiro, R., Amirabdollahian, F., Topping, M., Driessen, B., & Harwin, W. (2003) · Autonomous Robots · doi:10.1023/a:1024436732030 · Cited by 388
Web-based telerehabilitation for the upper extremity after stroke
Reinkensmeyer, D. J., Pang, C. T., Nessler, J. A., & Painter, C. C. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.1031978 · Cited by 290
Lum, P. S., Burgar, C. G., & Shor, P. C. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827225 · Cited by 281
Self-citationNEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
Assessment of movement quality in robot- assisted upper limb rehabilitation after stroke: a review
Nordin, N., Xie, S., & Wünsche, B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-137 · Cited by 271
Design, Implementation and Clinical Tests of a Wire-Based Robot for Neurorehabilitation
Rosati, G., Gallina, P., & Masiero, S. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.908560 · Cited by 267
Robot-Assisted Adaptive Training: Custom Force Fields for Teaching Movement Patterns
Patton, J. L., & Mussa-Ivaldi, F. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.821035 · Cited by 266
Changing Motor Synergies in Chronic Stroke
Dipietro, L., Krebs, H. I., Fasoli, S. E., Volpe, B. T., Stein, J., Bever, C., & Hogan, N. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01295.2006 · Cited by 263
Advances in upper limb stroke rehabilitation: a technology push
Loureiro, R. C. V., Harwin, W. S., Nagai, K., & Johnson, M. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0797-0 · Cited by 252
Customized interactive robotic treatment for stroke: EMG-triggered therapy
Dipietro, L., Ferraro, M., Palazzolo, J. J., Krebs, H. I., Volpe, B. T., & Hogan, N. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.850423 · Cited by 241
“Examples include MIT-MANUS [6], ARM Guide [7], and MIME [8].”
MethodKamper, D. G., McKenna-Cole, A. N., Kahn, L. E., & Reinkensmeyer, D. J. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2002.32446 · Cited by 236
The Present and Future of Robotic Technology in Rehabilitation
Laut, J., Porfiri, M., & Raghavan, P. (2016) · Current Physical Medicine and Rehabilitation Reports · doi:10.1007/s40141-016-0139-0 · Cited by 179
Assessing Mechanisms of Recovery During Robot-Aided Neurorehabilitation of the Upper Limb
Colombo, R., Pisano, F., Micera, S., Mazzone, A., Delconte, C., Carrozza, M. C., Dario, P., & Minuco, G. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968307303401 · Cited by 167
Biomechanics of reaching: clinical implications for individuals with acquired brain injury
McCrea, P. H., Eng, J. J., & Hodgson, A. J. (2002) · Disability and Rehabilitation · doi:10.1080/09638280110115393 · Cited by 158
The design of a five-degree-of-freedom powered orthosis for the upper limb
Johnson, G. R., Carus, D. A., Parrini, G., Marchese, S., & Valeggi, R. (2001) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411011535867 · Cited by 91
Metadata
- Authors
- Lum, P. S., Burgar, C. G., Kenney, D. E., & Van der Loos, H. F. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999-06
- Volume
- 46
- Issue
- 6
- Pages
- 652-662
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2139618082
- Cited by
- 142
- References
- 1
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.