Perforated silicon nerve chips with doped registration electrodes: in vitro performance and in vivo operation
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
An in vitro model was developed for the study of signal transduction between a Cu-wire, miming a neural signal source, and recording electrodes on perforated silicon chips. Phosphorous doped electrodes were used to achieve an all silicon device. The model was used to study signal amplitude as a function of the spatial position, and distance to the signal source. Recordings of the signal crosstalk to neighboring electrodes on the chips were made. It was found that the amplitude decreased by a factor of two at a distance of 50 microns between the electrode surface and the signal source. The chip electrode signal crosstalk was found to be 6 dB using an external reference electrode. Improvements were accomplished with an on chip reference electrode giving a crosstalk suppression of 20 dB. Impedance analysis showed that doped silicon electrodes displayed similar characteristics as Cu-electrodes at frequencies above 3 kHz. Sieve electrodes were implanted in the rat sciatic nerve and following a 10-week nerve regeneration period the dorsal and ventral (L5) roots in the spinal cord were stimulated. Compound action potentials were recorded via the chip. Stimulating the regenerated sciatic nerve via the sieve electrode also induced lower leg muscle contraction activity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 168
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161
Long term chronic recordings from peripheral sensory fibers using a sieve electrode array
Bradley, R. M., Cao, X., Akin, T., & Najafi, K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02225-5 · Cited by 69 · cited 1×
“In vivo recordings of neural activity from such devices have been demonstrated [6]–[11].”
BackgroundPeripheral nerve regeneration through microelectrode arrays based on silicon technology
Navarro, X., Calvet, S., Butí, M., Gómez, N., Cabruja, E., Garrido, P., Villa, R., & Valderrama, E. (1996) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-1996-9303 · Cited by 46
Cited by
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46
Stoyanova, I. I., van Wezel, R. J. A., & Rutten, W. L. C. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066018 · Cited by 18
Metadata
- Authors
- Wallman, L., Levinsson, A., Schouenborg, J., Holmberg, H., Danielsen, N., & Laurell, T.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1999
- Volume
- 46
- Issue
- 9
- Pages
- 1065-1073
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2113753837
- Cited by
- 29
- References
- 4
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.