In vivo testing of a 3D bifurcating microchannel scaffold inducing separation of regenerating axon bundles in peripheral nerves
Open accessAbstract
Artificial nerve guidance channels enhance the regenerative effectiveness in an injured peripheral nerve but the existing design so far has been limited to basic straight tubes simply guiding the growth to bridge the gap. Hence, one of the goals in development of more effective neuroprostheses is to create bidirectional highly selective neuro-electronic interface between a prosthetic device and the severed nerve. A step towards improving selectivity for both recording and stimulation have been made with some recent in vitro studies which showed that three-dimensional (3D) bifurcating microchannels can separate neurites growing on a planar surface and bring them into contact with individual electrodes. Since the growing axons in vivo have the innate tendency to group in bundles surrounded by connective tissue, one of the big challenges in neuro-prosthetic interface design is how to overcome it. Therefore, we performed experiments with 3D bifurcating guidance scaffolds implanted in the sciatic nerve of rats to test if this new channel architecture could trigger separation pattern of ingrowth also in vivo. Our results showed that this new method enabled the re-growth of neurites into channels with gradually diminished width (80, 40 and 20 µm) and facilitated the separation of the axonal bundles with 91% success. It seems that the 3D bifurcating scaffold might contribute towards conveying detailed neural control and sensory feedback to users of prosthetic devices, and thus could improve the quality of their daily life.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Cuff electrodes can be inserted into the gap of a nerve lesion and the nerve allowed to grow through it, rather than wrapping the cuff around a healthy nerve.
“Cuff electrodes can be inserted into the gap of a nerve lesion and the nerve allowed to grow through it, rather than wrapping the cuff around a healthy nerve (Lotfi et al., 2011; Stoyanova et al., 2013; Thompson et al., 2015).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Stoyanova et al., 2013
The Introduction (page unavailable) says axons can regenerate through an electrode structure placed at a sectioned nerve, supporting the grow-through approach. But it identifies those devices as regenerative or sieve electrodes and distinguishes them from cuff electrodes, which it describes as extraneural devices used on intact nerves. It does not support calling the device inserted at the lesion a cuff electrode. (LLM, conf=0.88)
Experimental — accuracy not yet measuredStoyanova et al. 3D bifurcating electrode arrays showed promise in facilitating bifurcation of large regenerated fascicles into smaller, almost singularly separated axonal fibers in vivo.
“When tested in vivo, these electrode arrays showed promise in facilitating bifurcation of large regenerated fascicles into smaller (almost singularly) separated axonal fibers”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [35]
The Results and Discussion report that the implanted 3D bifurcating scaffold separated regenerating axonal bundles in vivo, with 91% separation into secondary channels. But the paper describes an implanted microchannel scaffold, not an electrode array, and presents contact with single axons or small groups as a future possibility rather than an observed outcome (Discussion; page unavailable). (LLM, conf=0.88)
Experimental — accuracy not yet measuredRegenerated fibers in the Stoyanova arrays contained both myelinated and unmyelinated fibers of varying diameter, suggesting the possible presence of motor, autonomic, and sensory neurites.
“These regenerated fibers contained both myelinated and unmyelinated fibers of varying diameter, which suggests the possible presence of motor, autonomic, and sensory neurites.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [35]
Microchannel-based devices guide regenerating axons and parcel outgrowth toward distinct target locations.
“Microchannel-based devices guide regenerating axons and parcel outgrowth toward distinct target locations.”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [35]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Hsu, S. M., Raine, L., & Fanger, H. (1981) · Journal of Histochemistry & Cytochemistry · doi:10.1177/29.4.6166661 · Cited by 14,248 · see citing works
Degeneration and Regeneration of the Nervous System.
(1929) · JAMA · doi:10.1001/jama.1929.02710220063037 · Cited by 2,920 · see citing works
DEVELOPMENT OF THE VERTEBRATE NEUROMUSCULAR JUNCTION
Sanes, J. R., & Lichtman, J. W. (1999) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.22.1.389 · Cited by 1,532 · see citing works
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893 · see citing works
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658 · cited 6× · see citing works
“The stumps were then placed in a silicone tube, in a close apposition to the PDMS microchannel stack.”
BackgroundInfluentialIdé, C. (1996) · Neuroscience Research · doi:10.1016/0168-0102(96)01042-5 · Cited by 599 · see citing works
The anatomy and physiology of nerve injury
Sunderland, S. S. (1990) · Muscle & Nerve · doi:10.1002/mus.880130903 · Cited by 551 · see citing works
Microfluidic culture platform for neuroscience research
Park, J. W., Vahidi, B., Taylor, A. M., Rhee, S. W., & Jeon, N. L. (2006) · Nature Protocols · doi:10.1038/nprot.2006.316 · Cited by 466 · see citing works
Sensory feedback in upper limb prosthetics
Antfolk, C., D’Alonzo, M., Rosén, B., Lundborg, G., Sebelius, F., & Cipriani, C. (2013) · Expert Review of Medical Devices · doi:10.1586/erd.12.68 · Cited by 466 · see citing works
Two new fluorescent retrograde neuronal tracers which are transported over long distances
Bentivoglio, M., Kuypers, H. G. J. M., Catsman‐Berrevoets, C. E., Loewe, H., & Dann, O. (1980) · Neuroscience Letters · doi:10.1016/0304-3940(80)90208-6 · Cited by 442 · see citing works
Peripheral nerve regeneration through guidance tubes
Belkas, J. S., Shoichet, M. S., & Midha, R. (2004) · Neurological Research · doi:10.1179/016164104225013798 · Cited by 417 · see citing works
Fiber composition of the rat sciatic nerve
Schmalbruch, H. (1986) · The Anatomical Record · doi:10.1002/ar.1092150111 · Cited by 402 · see citing works
Recovery of fibre numbers and diameters in the regeneration of peripheral nerves
GUTMANN, E., & SANDERS, F. K. (1943) · The Journal of Physiology · doi:10.1113/jphysiol.1943.sp004002 · Cited by 398 · see citing works
Chronic relapsing polyneuritis
Prineas, J. W., & McLeod, J. G. (1976) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(76)90213-6 · Cited by 370 · see citing works
Cajal's Degeneration and Regeneration of the Nervous System
y Cajal, S. R., & May, R. M. (1991) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195065169.001.0001 · Cited by 367 · see citing works
Dhillon, G. S., Lawrence, S. M., Hutchinson, D. T., & Horch, K. W. (2004) · The Journal of Hand Surgery · doi:10.1016/j.jhsa.2004.02.006 · Cited by 354 · cited 1× · see citing works
“Such longitudinal intrafascicular electrodes (LIFE) (Lefurge et al 1991) have been used successfully for motor signal recording and sensory fibers stimulation in humans (Dhillon et al 2004).”
BackgroundLebedev, M., Carmena, J. M., O’Doherty, J. E., Zacksenhouse, M., Henriquez, C. S., Príncipe, J. C., & Nicolelis, M. A. L. (2005) · Journal of Neuroscience · doi:10.1523/jneurosci.4088-04.2005 · Cited by 291 · see citing works
Kuiken, T., Marasco, P. D., Lock, B. A., Harden, R. N., & Dewald, J. P. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706525104 · Cited by 284 · see citing works
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276 · see citing works
Self-citationChanges in nerve fiber numbers distal to a nerve repair in the rat sciatic nerve model
Mackinnon, S. E., Dellon, A. L., & O'Brien, J. P. (1991) · Muscle & Nerve · doi:10.1002/mus.880141113 · Cited by 270 · see citing works
Effects of aging on nerve sprouting and regeneration
Pestronk, A., Drachman, D. B., & Griffin, J. W. (1980) · Experimental Neurology · doi:10.1016/0014-4886(80)90006-0 · Cited by 259 · see citing works
Aguayo, A. J., Epps, J., Charron, L., et al. (1976) · Brain Research · doi:10.1016/0006-8993(76)90643-0 · Cited by 247 · see citing works
Pathway sampling by regenerating peripheral axons
Witzel, C., Rohde, C. A., & Brushart, T. M. E. (2005) · The Journal of Comparative Neurology · doi:10.1002/cne.20436 · Cited by 238 · see citing works
Badia, J., Boretius, T., Andreu, D., Azevedo-Coste, C., Stieglitz, T., & Navarro, X. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/036023 · Cited by 227 · see citing works
Principles Underlying New Methods for Chronic Neural Recording
Stein, R. B., Charles, D., DAVIS, L. A., Jhamandas, J. H., Mannard, A., & Nichols, T. R. (1975) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100020333 · Cited by 211 · see citing works
Intrinsic neuronal determinants of regeneration
Fawcett, J. W. (1992) · Trends in Neurosciences · doi:10.1016/0166-2236(92)90338-9 · Cited by 185 · see citing works
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · see citing works
Myelination determines the caliber of dorsal root ganglion neurons in culture
Aj, W., Wood, P. M., Bunge, R. P., & Pj, D. (1985) · Journal of Neuroscience · doi:10.1523/jneurosci.05-06-01563.1985 · Cited by 175 · see citing works
Chronically implanted intrafascicular recording electrodes
Lefurge, T., Goodall, E., Horch, K., Stensaas, L., & Schoenberg, A. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02368469 · Cited by 172 · see citing works
Regeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 164 · cited 1× · see citing works
“Sieve electrodes are flat thin silicone sheets perforated with an array of electrode holes (Kovacs et al 1992, Mensinger et al 2000) or insulating plastics such as polyimide (Navarro et al 1998).”
BackgroundDworak, B. J., & Wheeler, B. C. (2008) · Lab on a Chip · doi:10.1039/b806689b · Cited by 163 · see citing works
ENGINEERING STRATEGIES FOR PERIPHERAL NERVE REPAIR
Hudson, T. W., Evans, G. R. D., & Schmidt, C. E. (2000) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(05)70166-8 · Cited by 137 · see citing works
New depths in cell behaviour: reactions of cells to nanotopography.
Curtis, A. S. G., & Wilkinson, C. (1999) · PubMed · Cited by 134 · see citing works
Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
Rutten, W. L. C., van Wier, H. J., & Put, J. H. M. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76386 · Cited by 129 · see citing works
Self-citationVleggeert-Lankamp, C. L. A. (2007) · Journal of neurosurgery · doi:10.3171/jns-07/12/1168 · Cited by 127 · see citing works
Belkas, J. S., Munro, C. A., Shoichet, M. S., et al. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.05.031 · Cited by 119 · see citing works
(1998) · PubMed · Cited by 107 · see citing works
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98 · see citing works
Valero‐Cabré, A., & Navarro, X. (2002) · Journal of Neurotrauma · doi:10.1089/089771502320914705 · Cited by 93 · see citing works
Epineurial and perineurial fascicular nerve repairs: A critical comparison
Cabaud, H. E., Rodkey, W. G., McCarroll, H. R., et al. (1976) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(76)80006-8 · Cited by 92 · see citing works
ISONIAZID NEUROPATHY IN MAN: QUANTITATIVE ELECTRON MICROSCOPE STUDY
Ochoa, J. L. (1970) · Brain · doi:10.1093/brain/93.4.831 · Cited by 92 · see citing works
The sural nerve of the human foetus: electron microscope observations and counts of axons.
Ochoa, J. (1971) · PubMed · Cited by 86 · see citing works
Mannard, A., Stein, R. B., & Charles, D. (1974) · Science · doi:10.1126/science.183.4124.547 · Cited by 85 · see citing works
Chronic recording of regenerating viiith nerve axons with a sieve electrode
Mensinger, A. F., Anderson, D. J., Buchko, C. J., Johnson, M. A., Martin, D. C., Tresco, P. A., Silver, R. B., & Highstein, S. M. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.83.1.611 · Cited by 76 · see citing works
Reactions of unmyelinated nerve fibers to injury. An ultrastructural study
Bray, G. M., Peyronnard, J. M., & Aguayo, A. J. (1972) · Brain Research · doi:10.1016/0006-8993(72)90532-x · Cited by 76 · see citing works
Engineering a multimodal nerve conduit for repair of injured peripheral nerve
Quigley, A. F., Bulluss, K. J., Kyratzis, I. L. B., Gilmore, K. J., Mysore, T. B., Schirmer, K., Kennedy, E. L., O’Shea, M., Truong, Y. B., Edwards, S. L., et al. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/016008 · Cited by 75 · see citing works
Rat sciatic nerve regeneration through a micromachined silicon chip
Zhao, Q., Drott, J., Laurell, T., Wallman, L., Lindström, K., Bjursten, L. M., Lundborg, G., Montelius, L., & Danielsen, N. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00112-3 · Cited by 67 · see citing works
Klinge, P. M., Vafa, M. A., Brinker, T., Brandis, A., Walter, G. F., Stieglitz, T., Samii, M., & Wewetzer, K. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00420-8 · Cited by 64 · see citing works
Three Dimensional Analysis of Unmyelinated Fibers in Normal and Pathologic Autonomic Nerves
Aguayo, A. J., Bray, G. M., Terry, L. C., et al. (1976) · Journal of Neuropathology & Experimental Neurology · doi:10.1097/00005072-197603000-00002 · Cited by 62 · see citing works
Ceballos, D., Valero‐Cabré, A., Valderrama, E., Schüttler, M., Stieglitz, T., & Navarro, X. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10099 · Cited by 61 · see citing works
Early interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56 · see citing works
Negredo, P., Castro, J. E., Lago, N., Navarro, X., & Avendaño, C. (2004) · Neuroscience · doi:10.1016/j.neuroscience.2004.07.017 · Cited by 55 · see citing works
Chronic Measurement of the Stimulation Selectivity of the Flat Interface Nerve Electrode
Leventhal, D. K., & Durand, D. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827535 · Cited by 55 · see citing works
Axonal regeneration and motor neuron survival after microsurgical nerve reconstruction
Fox, I. K., Brenner, M. J., Johnson, P. J., Hunter, D. A., & Mackinnon, S. E. (2012) · Microsurgery · doi:10.1002/micr.22036 · Cited by 48 · see citing works
Ramachandran, A., Schuettler, M., Lago, N., Doerge, T., Koch, K. P., Navarro, X., Hoffmann, K.-P., & Stieglitz, T. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/2/005 · Cited by 46 · see citing works
Multisite Recording of Extracellular Potentials Produced by Microchannel-Confined Neurons In-Vitro
Claverol-Tinturé, E., Cabestany, J., & Rosell, X. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880903 · Cited by 46 · see citing works
Rutten, W. L. C., Frieswijk, T. A., Smit, J. P. A., Rozijn, T. H., & Meier, J. H. (1995) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(95)96802-6 · Cited by 43 · see citing works
Self-citationModality-Specific Axonal Regeneration: Toward Selective Regenerative Neural Interfaces
Lotfi, P., Garde, K., Chouhan, A. K., Bengali, E., & Romero-Ortega, M. I. (2011) · Frontiers in Neuroengineering · doi:10.3389/fneng.2011.00011 · Cited by 42 · see citing works
The effect of denervated muscle and Schwann cells on axon collateral sprouting
Chen, Y.-G., & Brushart, T. M. E. (1998) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(98)80010-5 · Cited by 40 · see citing works
Slowing of axonal regeneration is correlated with increased axonal viscosity during aging
Lamoureux, P., O’Toole, M., Heidemann, S. R., et al. (2010) · BMC Neuroscience · doi:10.1186/1471-2202-11-140 · Cited by 38 · see citing works
Differential transport of DNA by a rectified Brownian motion device
Hammond, R. W., Bader, J. S., Henck, S. A., Deem, M. W., McDermott, G. A., Bustillo, J. M., & Rothberg, J. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1 · Cited by 37 · see citing works
Porous silicon as a potential electrode material in a nerve repair setting: Tissue reactions
Johansson, F., Wallman, L., Danielsen, N., et al. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.02.010 · Cited by 32 · see citing works
Wallman, L., Levinsson, A., Schouenborg, J., Holmberg, H., Danielsen, N., & Laurell, T. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.784137 · Cited by 29 · see citing works
Panetsos, F., Avendano, C., Negredo, P., Castro, J. E., & Bonacasa, V. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.923707 · Cited by 20 · see citing works
Bifurcating microchannels as a scaffold to induce separation of regenerating neurites
Wieringa, P. A., Wiertz, R. W. F., de Weerd, E. L., & Rutten, W. L. C. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/1/016001 · Cited by 18 · see citing works
Self-citationWieringa, P. A., Wiertz, R. W. F., de Weerd, E. L., & Rutten, W. L. C. (2010) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2038950 · Cited by 13 · see citing works
Self-citationFascicle-Selectivity of an Intraneural Stimulation Electrode in the Rabbit Sciatic Nerve
Nielsen, T. N., Sevcencu, C., & Struijk, J. J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2169671 · Cited by 11 · see citing works
Davenport, H., Chor, H., & Cleveland, D. A. (1939) · The Journal of Comparative Neurology · doi:10.1002/cne.900700109 · Cited by 11 · see citing works
Nanomodified surfaces and guidance of nerve cell processes
Johansson, F., Hällström, W., Gustavsson, P., et al. (2008) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.2998698 · Cited by 6 · see citing works
Neural growth into a microchannel network: Towards A regenerative neural interface
Wieringa, P. A., Wiertz, R. W. F., le Feber, J., & Rutten, W. L. C. (2009) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2009.5109232 · Cited by 5 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics
Carnicer-Lombarte, A., Chen, S.-T., Malliaras, G. G., & Barone, D. G. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.622524 · Cited by 454 · see citing works
“Cuff electrodes can be inserted into the gap of a nerve lesion and the nerve allowed to grow through it, rather than wrapping the cuff around a healthy nerve (Lotfi et al., 2011; Stoyanova et al., 2013; Thompson et al., 2015).”
BackgroundImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Regenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67 · see citing works
Update in facial nerve paralysis: tissue engineering and new technologies
Langhals, N. B., Urbanchek, M. G., Ray, A., & Brenner, M. J. (2014) · Current Opinion in Otolaryngology & Head and Neck Surgery · doi:10.1097/moo.0000000000000062 · Cited by 41 · see citing works
Fascicular nerve stimulation and recording using a novel double-aisle regenerative electrode
Delgado-Martínez, I., Righi, M., Santos, D., Cutrone, A., Bossi, S., D’Amico, S., Del Valle, J., Micera, S., & Navarro, X. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6bac · Cited by 35 · see citing works
Gore, R. K., Choi, Y., Bellamkonda, R., & English, A. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016017 · Cited by 26 · see citing works
Wu, Y., & Guo, L. (2020) · Neural Interface Engineering · doi:10.1007/978-3-030-41854-0_5 · Cited by 3 · see citing works
- Authors
- Stoyanova, I. I., van Wezel, R. J. A., & Rutten, W. L. C.
- Affiliations
- University of Twente (NL)
- Corresponding author
- Stoyanova, Irina I
- Venue
- Journal of Neural Engineering
- Publisher
- IOP Publishing
- Published
- 2013-11-27
- Volume
- 10
- Issue
- 6
- Pages
- 066018
- ISSN
- 1741-2552 (ISSN-L)
- 1741-2560
- OpenAlex
- W2167986300
- Cited by
- 18
- References
- 71
- Citations by year
- 2025: 2 · 2021: 2 · 2020: 1 · 2019: 4 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 3 · 2014: 2
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Neural Engineering (publishedVersion)
- PubMed (publishedVersion)
- University of Twente Research Information (publishedVersion)
- Radboud Repository (Radboud University) (submittedVersion)
- Radboud Repository (Radboud University) (submittedVersion, other-oa)
- University of Twente Research Information (submittedVersion)
- Funders
- Radboud Universiteit
- University of Twente
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- peripheral nerve regeneration, nerve guidance channels, sciatic nerve, in vivo implantation
- MeSH terms
- Animals, Axons, Female, Microelectrodes, Nerve Regeneration, Organ Culture Techniques, Peripheral Nerves, Sciatic Nerve, Rats, Wistar, Rats, Tissue Scaffolds
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review