The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Wavelet compression of ECG signals by the set partitioning in hierarchical trees algorithm
Abstract
A wavelet electrocardiogram (ECG) data codec based on the set partitioning in hierarchical trees (SPIHT) compression algorithm is proposed in this paper. The SPIHT algorithm [1] has achieved notable success in still image coding. We modified the algorithm for the one-dimensional case and applied it to compression of ECG data. Experiments on selected records from the MIT-BIH arrhythmia database revealed that the proposed codec is significantly more efficient in compression and in computation than previously proposed ECG compression schemes. The coder also attains exact bit rate control and generates a bit stream progressive in quality or rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Wavelet Tour of Signal Processing
(1999) · Elsevier eBooks · doi:10.1016/b978-0-12-466606-1.x5000-4 · Cited by 16,227
A new, fast, and efficient image codec based on set partitioning in hierarchical trees
Said, A., & Pearlman, W. A. (1996) · IEEE Transactions on Circuits and Systems for Video Technology · doi:10.1109/76.499834 · Cited by 5,353
Self-citationImage coding using wavelet transform
Antonini, M., Barlaud, M., Mathieu, P., & Daubechies, I. (1992) · IEEE Transactions on Image Processing · doi:10.1109/83.136597 · Cited by 3,525
A Wavelet Tour of Signal Processing
(2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374370-1.x0001-8 · Cited by 1,886
ECG data compression techniques-a unified approach
Jalaleddine, S. M. S., Hutchens, C. G., Strattan, R. D., & Coberly, W. A. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52340 · Cited by 681
Wavelet and wavelet packet compression of electrocardiograms
Hilton, M. L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568915 · Cited by 415
ECG coding by wavelet-based linear prediction
Ramakrishnan, A. G., & Saha, S. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.649997 · Cited by 130
Wavelet packet-based compression of single lead ECG
Bradie, B. D. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488797 · Cited by 119
Çetin, A. E., Köymen, H., & Aydin, M. C. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243411 · Cited by 79
Cited by
Rahmani, A. M., Gia, T. N., Negash, B., Anzanpour, A., Azimi, I., Jiang, M., & Liljeberg, P. (2018) · Future Generation Computer Systems · doi:10.1016/j.future.2017.02.014 · Cited by 1,198
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
“with sleep apnoea/hyponeoa syndrome (SAHS). They compared their spectral analysis of the HRV signals with the current screening method of pulse oximetry. Their results indicated that spectral analysis of HRV appears to provide a better indicator of SAHS than oximetry in non-REM sleep and a comparable indicator in REM…”
MethodResultInfluentialCompressed Sensing for Real-Time Energy-Efficient ECG Compression on Wireless Body Sensor Nodes
Mamaghanian, H., Khaled, N., Atienza, D., & Vandergheynst, P. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2156795 · Cited by 701
ECG Denoising and Compression Using a Modified Extended Kalman Filter Structure
Sayadi, O., & Shamsollahi, M. B. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.921150 · Cited by 254
Metadata
- Authors
- Lu, Z., Kim, D. Y., & Pearlman, W. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2000-07
- Volume
- 47
- Issue
- 7
- Pages
- 849-856
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2104655872
- Cited by
- 497
- References
- 9
- FWCI
- 5.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.