An implantable power supply with an optically rechargeable lithium battery

Goto, K., Nakagawa, T., Nakamura, O., Kawata, S.·2001·IEEE Transactions on Biomedical Engineering

Abstract

A novel power supply for medical implants has been developed. A wireless near-infrared power transmission recharges a lithium secondary battery in the power supply. A photovoltaic cell array embedded under skin receives near-infrared light through the skin and charges the battery directly powering an implanted device. We have shown that, for a photodiode area of 2.1 cm2, 17 min of near-infrared irradiation at a 810-nm wavelength with a power density of 22 mW/cm2 can send enough energy to allow regular commercial cardiac pacemakers to run for 24 h. The temperature rise of the skin during the light irradiation was 1.4 degrees C.

Integrity signals

Registry

Crossref · 10.1109/10.930908

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Using a photodiode area of 2.1, roughly 17 min of NIR light exposure at a power density of 22 mW/cm was sufficient to power a commercial cardiac pacemaker for 24 h.

    “For instance, using a photodiode area of 2.1 roughly 17 min of NIR light exposure at a power density of 22 mW/cm was sufficient to power a commercial cardiac pacemaker for 24 h (Goto et al., 2001).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Goto et al., 2001

  • 810-nm wavelength NIR light could effectively charge a lithium secondary battery embedded in an implant, providing a direct power supply.

    “For instance, research at Osaka University has shown that 810-nm wavelength NIR light could effectively charge a lithium secondary battery embedded in the implant, providing a direct power supply (Goto et al., 2001).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Goto et al., 2001

  • Some studies recorded a modest temperature rise of 1.4°C in the skin during light irradiation.

    “While some studies have recorded a modest temperature rise of 1.4°C in the skin during light irradiation (Goto et al., 2001) others found no noticeable side effects or temperature changes during a 60-min charging period for cardiac pacemakers.”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Goto et al., 2001

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Goto, K., Nakagawa, T., Nakamura, O., & Kawata, S.
Affiliations
The University of Osaka (JP)
Venue
IEEE Transactions on Biomedical Engineering
Published
2001-07
Volume
48
Issue
7
Pages
830-833
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2104708213
Cited by
159
References
11
Citations by year
2026: 6 · 2025: 4 · 2024: 6 · 2023: 14 · 2022: 9 · 2021: 12 · 2020: 10 · 2019: 10 · 2018: 9 · 2017: 9 · 2016: 5 · 2015: 13 · 2014: 6 · 2013: 6 · 2012: 7
FWCI
1.25
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Photodynamic Therapy Research Studies
Keywords
implantable power sources, lithium-ion batteries, cardiac pacemaker
MeSH terms
Animals, Equipment Design, Humans, Infrared Rays, Lithium, Pacemaker, Artificial, Electric Power Supplies, Prostheses and Implants, Rats

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review