The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Detection and measurement of retinal vessels in fundus images using amplitude modified second-order Gaussian filter
Abstract
In this paper, the fitness of estimating vessel profiles with Gaussian function is evaluated and an amplitude-modified second-order Gaussian filter is proposed for the detection and measurement of vessels. Mathematical analysis is given and supported by a simulation and experiments to demonstrate that the vessel width can be measured in linear relationship with the "spreading factor" of the matched filter when the magnitude coefficient of the filter is suitably assigned. The absolute value of vessel diameter can be determined simply by using a precalibrated line, which is typically required since images are always system dependent. The experiment shows that the inclusion of the width measurement in the detection process can improve the performance of matched filter and result in a significant increase in success rate of detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
An advanced detrending method with application to HRV analysis
Tarvainen, M. P., Ranta-aho, P. O., & Karjalainen, P. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979357 · Cited by 1,131
Hawkes, P. W. (1978) · Nature · doi:10.1038/272740a0 · Cited by 827
Can, A., Shen, H., Turner, Tanenbaum, & Roysam (1999) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.767088 · Cited by 434
The detection and quantification of retinopathy using digital angiograms
Zhou, L., Rzeszotarski, M. S., Singerman, L. J., & Chokreff, J. M. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363106 · Cited by 292
Retinal blood vessel detection and tracking by matched Gaussian and Kalman filters
Chutatape, O., Zheng, L., & Krishnan, S. M. (2002) · Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286) · doi:10.1109/iembs.1998.746160 · Cited by 228
Self-citation
Cited by
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
A Cross-Modality Learning Approach for Vessel Segmentation in Retinal Images
Li, Q., Feng, B., Xie, L., Liang, P., Zhang, H., & Wang, T. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2457891 · Cited by 571
Zhao, Y., Rada, L., Chen, K., Harding, S. P., & Zheng, Y. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2409024 · Cited by 391
Metadata
- Authors
- Gang, L., Chutatape, O., & Krishnan, S. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2002
- Volume
- 49
- Issue
- 2
- Pages
- 168-172
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2100072940
- Cited by
- 294
- References
- 8
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection and measurement of retinal vessels in fundus images using amplitude modified second-order Gaussian filter. https://app.cochat.ai/papers/10.1109/10.979356
- The paper
- Gang, L., Chutatape, O., & Krishnan, S. M. (2002). Detection and measurement of retinal vessels in fundus images using amplitude modified second-order Gaussian filter. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.979356
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.