Medical applications of electroporation
Abstract
In vivo electroporation, first reported in 1987, makes it possible to render cell membranes temporarily permeable to substances that otherwise would not be able to effectively enter the cell interior. Micro- or millisecond pulses of electrical field strengths exceeding the natural cellular transmembrane potential difference of approximately I V results in permeabilization ("poration") of cell membranes. This phenomenon opens up numerous applications in the medical field. Electroporative delivery of chemotherapeutic drugs into tumor cells has proven successful in clinical studies to treat malignant tumors and is nearing market Introduction in Europe. For gene therapy applications, delivery of DNA by electroporation into a variety of tissues has been shown to consistently result in a 100-1000-fold enhancement of gene expression. Other applications of electroporation discussed in this paper include intravascular delivery of drugs and genes with electroporation catheters, electroinsertion of molecules into membranes, intraocular delivery of drugs and genes, and transdermal drug delivery. The use of electroporation for drug and gene delivery in vivo is clearly gaining momentum, and new medical applications are emerging at an increasing rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct Gene Transfer into Mouse Muscle in Vivo
Wolff, J. A., Malone, R. W., Williams, P., Chong, W., Acsadi, G., Jani, A., & Felgner, P. L. (1990) · Science · doi:10.1126/science.1690918 · Cited by 4,173
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Gene therapy vectors based on adeno-associated virus type 1
Xiao, W., Chirmule, N., Berta, S. C., McCullough, B., Gao, G., & Wilson, J. M. (1999) · Journal of Virology · doi:10.1128/jvi.73.5.3994-4003.1999 · Cited by 541
Vile, R. G., & Russell, S. J. (1995) · British Medical Bulletin · doi:10.1093/oxfordjournals.bmb.a072941 · Cited by 114
Cited by
Electroporation-Based Technologies for Medicine: Principles, Applications, and Challenges
Yarmush, M. L., Golberg, A., Serša, G., Kotnik, T., & Miklavčič, D. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104622 · Cited by 889
In Vivo Results of a New Focal Tissue Ablation Technique: Irreversible Electroporation
Edd, J. F., Horowitz, L., Davalos, R. V., Mir, L. M., & Rubinsky, B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873745 · Cited by 510
Modeling Electroporation in a Single Cell
Krassowska, W., & Filev, P. D. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.094235 · Cited by 501
Nanosecond, high‐intensity pulsed electric fields induce apoptosis in human cells
Beebe, S. J., Fox, P. M., Rec, L. J., Willis, L. K., & Schoenbach, K. H. (2003) · The FASEB Journal · doi:10.1096/fj.02-0859fje · Cited by 465
Theory and in Vivo Application of Electroporative Gene Delivery
Somiari, S., Glasspool-Malone, J., Drabick, J. J., Gilbert, R. A., Heller, R., Jaroszeski, M. J., & Malone, R. W. (2000) · Molecular Therapy · doi:10.1006/mthe.2000.0124 · Cited by 303
Metadata
- Authors
- Dev, S. B., Rabussay, D. P., Widera, G., & Hofmann, G. A.
- Venue
- IEEE Transactions on Plasma Science
- Published
- 2000
- Volume
- 28
- Issue
- 1
- Pages
- 206-223
- ISSN
- 0093-3813 (ISSN-L)
- OpenAlex
- W2118885206
- Cited by
- 225
- References
- 4
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medical applications of electroporation. https://app.cochat.ai/papers/10.1109/27.842905
- The paper
- Dev, S. B., Rabussay, D. P., Widera, G., & Hofmann, G. A. (2000). Medical applications of electroporation. IEEE Transactions on Plasma Science. https://doi.org/10.1109/27.842905
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.