The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Performance characterization of a high-power dual active bridge DC-to-DC converter
Abstract
The performance of a high-power, high-power-density DC-to-DC converter based on the single-phase dual active bridge (DAB) topology is described. The dual active bridge converter has been shown to have very attractive features in terms of low device and component stresses, small filter components, low switching losses, high power density and high efficiency, bidirectional power flow, buck-boost operation, and low sensitivity to system parasitics. For high output voltages, on the order of kilovolts, a cascaded output structure is considered. The effects of snubber capacitance and magnetizing inductance on the soft switching region of control are discussed. Various control schemes are outlined. Coaxial transformer design techniques have been utilized to carefully control leakage inductance. The layout and experimental performance of a prototype 50 kW 50 kHz unit operating with an input voltage of 200 V DC and an output voltage of 1600 V DC are presented.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
Self-citationPseudo-resonant full bridge DC/DC converter
Patterson, O. D., & Divan, D. M. (1991) · IEEE Transactions on Power Electronics · doi:10.1109/63.97767 · Cited by 235
Self-citationDesign considerations for high power high frequency transformers
Kheraluwala, M. H., Novotny, D. W., & Divan, D. M. (2002) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.1990.131262 · Cited by 85
Self-citationCoaxially wound transformers for high-power high-frequency applications
Kheraluwala, M. H., Novotny, D. W., & Divan, D. M. (1992) · IEEE Transactions on Power Electronics · doi:10.1109/63.124577 · Cited by 74
Self-citation
Cited by
Zhao, B., Song, Q., Liu, W., & Sun, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2289913 · Cited by 1,886
Bai, H., & Mi, C. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2008.2005103 · Cited by 1,121
Extreme Fast Charging of Electric Vehicles: A Technology Overview
Tu, H., Feng, H., Srdic, S., & Lukic, S. (2019) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2019.2958709 · Cited by 898
Biela, J., Schweizer, M., Waffler, S., & Kolar, J. W. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2072896 · Cited by 892
A Bidirectional DC–DC Converter for an Energy Storage System With Galvanic Isolation
Inoue, S., & Akagi, H. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.909248 · Cited by 780
Metadata
- Authors
- Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1992
- Volume
- 28
- Issue
- 6
- Pages
- 1294-1301
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2169607864
- Cited by
- 1,496
- References
- 4
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.