The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Analysis and design of a DC voltage-controlled static VAr compensator using quad-series voltage-source inverters
Open accessAbstract
This paper presents a DC voltage-controlled static VAr compensator (SVC) using quad-series voltage-source non-PWM inverters. The SVC consists of four three-phase voltage-source inverters having a common DC capacitor and four three-phase transformers, the primary windings of which are connected in series with each other. Although each inverter outputs a square wave voltage, the synthesized AC voltage of the SVC has a 24-step waveshape. This results not only in a great reduction of harmonic currents and DC voltage ripples but also in less switching and snubbing losses. This paper develops the analysis of the transient response and the resonance between the AC reactors and the DC capacitor, with the focus on practical use. Experimental results obtained from a 10-kVA laboratory system are shown to agree well with the analytical results, thus verifying the analysis and leading to the design of DC capacitance value.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akagi, H., Kanazawa, Y., & Nabae, A. (1984) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1984.4504460 · Cited by 3,377
Self-citationLeonhard, W. (1996) · Springer eBooks · doi:10.1007/978-3-642-97646-9 · Cited by 2,488
Reactive Power Generation and Control by Thyristor Circuits
Gyugyi, L. (1979) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1979.4503701 · Cited by 331
Cited by
Control and Experiment of Pulsewidth-Modulated Modular Multilevel Converters
Hagiwara, M., & Akagi, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2014236 · Cited by 1,565
Self-citationClassification, Terminology, and Application of the Modular Multilevel Cascade Converter (MMCC)
Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2143431 · Cited by 1,172
Self-citationA Medium-Voltage Motor Drive With a Modular Multilevel PWM Inverter
Hagiwara, M., Nishimura, K., & Akagi, H. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2042303 · Cited by 670
Self-citationControl and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration
Akagi, H., Inoue, S., & Yoshii, T. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.900487 · Cited by 643
Self-citationMultilevel Converters: Fundamental Circuits and Systems
Akagi, H. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2682105 · Cited by 513
Self-citationHagiwara, M., Maeda, R., & Akagi, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2089065 · Cited by 392
Self-citationHagiwara, M., Hasegawa, I., & Akagi, H. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2256331 · Cited by 291
Self-citationPWM control and experiment of modular multilevel converters
Hagiwara, M., & Akagi, H. (2008) · 2008 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2008.4591917 · Cited by 291
Self-citationHagiwara, M., Maeda, R., & Akagi, H. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2182330 · Cited by 265
Self-citationHagiwara, M., Maeda, R., & Akagi, H. (2010) · The 2010 International Power Electronics Conference - ECCE ASIA - · doi:10.1109/ipec.2010.5543517 · Cited by 60
Self-citation
Metadata
- Authors
- Fujita, H., Tominaga, S., & Akagi, H.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 1996
- Volume
- 32
- Issue
- 4
- Pages
- 970-978
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2143749737
- Cited by
- 275
- References
- 3
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.