Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 643

The DOI matches its Crossref record.

Control and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration

Akagi, Hirofumi, Inoue, Shigenori, Yoshii, Tsurugi·2007·IEEE Transactions on Industry Applications

Abstract

This paper presents a three-phase transformerless cascade pulsewidth-modulation (PWM) static synchronous compensator (STATCOM) intended for installation on industrial and utility power distribution systems. It proposes a control algorithm that devotes itself not only to meeting the demand of reactive power but also to voltage balancing of multiple galvanically isolated and floating dc capacitors. The control algorithm based on a phase-shifted carrier modulation strategy is prominent in having no restriction on the cascade number. Experimental waveforms verify that a 200-V 10-kVA cascade PWM STATCOM with star configuration has the capability of inductive to capacitive (or capacitive to inductive) operation at the rated reactive power of 10 kVA within 20 ms while keeping the nine dc mean voltages controlled and balanced even during the transient state.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tia.2007.900487

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 643

Metadata

Authors
Akagi, H., Inoue, S., & Yoshii, T.
Venue
IEEE Transactions on Industry Applications
Published
2007
Volume
43
Issue
4
Pages
1041-1049
ISSN
0093-9994 (ISSN-L)
OpenAlex
W2103829663
Cited by
643
References
0
FWCI
21.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration. https://app.cochat.ai/papers/10.1109/tia.2007.900487
The paper
Akagi, H., Inoue, S., & Yoshii, T. (2007). Control and Performance of a Transformerless Cascade PWM STATCOM With Star Configuration. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2007.900487

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).