The authors define ordered subset processing for standard algorithms (such as expectation maximization, EM) for image restoration from projections. Ordered subsets methods group projection data into an ordered sequence of subsets (or blocks). An iteration of ordered subsets EM is defined as a single pass through all the subsets, in each subset using the current estimate to initialize application of EM with that data subset. This approach is similar in concept to block-Kaczmarz methods introduced by Eggermont et al. (1981) for iterative reconstruction. Simultaneous iterative reconstruction (SIRT) and multiplicative algebraic reconstruction (MART) techniques are well known special cases. Ordered subsets EM (OS-EM) provides a restoration imposing a natural positivity condition and with close links to the EM algorithm. OS-EM is applicable in both single photon (SPECT) and positron emission tomography (PET). In simulation studies in SPECT, the OS-EM algorithm provides an order-of-magnitude acceleration over EM, with restoration quality maintained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
Iterative methods for the three-dimensional reconstruction of an object from projections
Gilbert, P. (1972) · Journal of Theoretical Biology · doi:10.1016/0022-5193(72)90180-4 · Cited by 1,421
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Green, P. J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52985 · Cited by 1,241
Generalized Iterative Scaling for Log-Linear Models
Darroch, J. N., & Ratcliff, D. (1972) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177692379 · Cited by 1,206
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
Hebert, T., & Leahy, R. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24868 · Cited by 622
On Use of the Em Algorithm for Penalized Likelihood Estimation
Green, P. J. (1990) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1990.tb01798.x · Cited by 417
Recursive Parameter Estimation Using Incomplete Data
Titterington, D. M. (1984) · Journal of the Royal Statistical Society Series B (Statistical Methodology) · doi:10.1111/j.2517-6161.1984.tb01296.x · Cited by 324
Implementing and Accelerating the EM Algorithm for Positron Emission Tomography
Kaufman, L. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307796 · Cited by 293
On Block-Iterative Entropy Maximization
Censor, Y., & Segman, J. (1987) · Journal of Information and Optimization Sciences · doi:10.1080/02522667.1987.10698894 · Cited by 66
An evaluation of maximum likelihood reconstruction for SPECT
Chornoboy, E. S., Chen, C. J., Miller, M. I., Miller, T. R., & Snyder, D. L. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52987 · Cited by 61
A primal-dual iterative algorithm for a maximum likelihood estimation problem
Iusem, A. N., & Teboulle, M. (1992) · Computational Statistics & Data Analysis · doi:10.1016/0167-9473(92)90060-s · Cited by 5
The use of small scale prototypes in image reconstruction from projections
Barnett, G., Crowe, S., Hudson, H. M., Leung, P.-L., Notodiputro, K. A., Proudfoot, R., & Sims, J. W. (1989) · Journal of Applied Statistics · doi:10.1080/02664768900000019 · Cited by 4
Self-citation
Cited by
A unified treatment of some iterative algorithms in signal processing and image reconstruction
Byrne, C. (2004) · Inverse Problems · doi:10.1088/0266-5611/20/1/006 · Cited by 1,339
Clinical Applications of PET in Oncology
Rohren, E. M., Turkington, T. G., & Coleman, R. E. (2004) · Radiology · doi:10.1148/radiol.2312021185 · Cited by 859
The EM Algorithm—an Old Folk-song Sung to a Fast New Tune
Meng, X.-L., & Van Dyk, D. (1997) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00082 · Cited by 802
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Metadata
- Authors
- Hudson, H. M., & Larkin, R. S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1994
- Volume
- 13
- Issue
- 4
- Pages
- 601-609
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2154744699
- Cited by
- 3,711
- References
- 14
- FWCI
- 20.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.