The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Accelerated image reconstruction using ordered subsets of projection data
Abstract
The authors define ordered subset processing for standard algorithms (such as expectation maximization, EM) for image restoration from projections. Ordered subsets methods group projection data into an ordered sequence of subsets (or blocks). An iteration of ordered subsets EM is defined as a single pass through all the subsets, in each subset using the current estimate to initialize application of EM with that data subset. This approach is similar in concept to block-Kaczmarz methods introduced by Eggermont et al. (1981) for iterative reconstruction. Simultaneous iterative reconstruction (SIRT) and multiplicative algebraic reconstruction (MART) techniques are well known special cases. Ordered subsets EM (OS-EM) provides a restoration imposing a natural positivity condition and with close links to the EM algorithm. OS-EM is applicable in both single photon (SPECT) and positron emission tomography (PET). In simulation studies in SPECT, the OS-EM algorithm provides an order-of-magnitude acceleration over EM, with restoration quality maintained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
Iterative methods for the three-dimensional reconstruction of an object from projections
Gilbert, P. (1972) · Journal of Theoretical Biology · doi:10.1016/0022-5193(72)90180-4 · Cited by 1,421
Bayesian reconstructions from emission tomography data using a modified EM algorithm
Green, P. J. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.52985 · Cited by 1,241
Generalized Iterative Scaling for Log-Linear Models
Darroch, J. N., & Ratcliff, D. (1972) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177692379 · Cited by 1,206
A Statistical Model for Positron Emission Tomography
Vardi, Y., Shepp, L. A., & Kaufman, L. (1985) · Journal of the American Statistical Association · doi:10.1080/01621459.1985.10477119 · Cited by 863
A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors
Hebert, T., & Leahy, R. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.24868 · Cited by 622
On Use of the Em Algorithm for Penalized Likelihood Estimation
Green, P. J. (1990) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1990.tb01798.x · Cited by 417
Recursive Parameter Estimation Using Incomplete Data
Titterington, D. M. (1984) · Journal of the Royal Statistical Society Series B (Statistical Methodology) · doi:10.1111/j.2517-6161.1984.tb01296.x · Cited by 324
Implementing and Accelerating the EM Algorithm for Positron Emission Tomography
Kaufman, L. (1987) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1987.4307796 · Cited by 293
Cited by
A unified treatment of some iterative algorithms in signal processing and image reconstruction
Byrne, C. (2004) · Inverse Problems · doi:10.1088/0266-5611/20/1/006 · Cited by 1,339
Clinical Applications of PET in Oncology
Rohren, E. M., Turkington, T. G., & Coleman, R. E. (2004) · Radiology · doi:10.1148/radiol.2312021185 · Cited by 859
The EM Algorithm—an Old Folk-song Sung to a Fast New Tune
Meng, X.-L., & Van Dyk, D. (1997) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00082 · Cited by 802
Exact and approximate rebinning algorithms for 3-D PET data
Defrise, M., Kinahan, P. E., Townsend, D. W., Michel, C., Sibomana, M., & Newport, D. F. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563660 · Cited by 758
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Statistical image reconstruction for polyenergetic X-ray computed tomography
Elbakri, I. A., & Fessler, J. A. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993128 · Cited by 691
High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
Qi, J., Leahy, R. M., Cherry, S. R., Chatziioannou, A., & Farquhar, T. H. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/027 · Cited by 635
Single photon-emission computed tomography
Holly, T. A., Abbott, B. G., Al-Mallah, M., Calnon, D. A., Cohen, M. C., DiFilippo, F. P., Ficaro, E. P., Freeman, M. R., Hendel, R. C., Jain, D., et al. (2010) · Journal of Nuclear Cardiology · doi:10.1007/s12350-010-9246-y · Cited by 597
Inhibition of mitochondrial fission prevents cell cycle progression in lung cancer
Rehman, J., Zhang, H. J., Toth, P. T., Zhang, Y., Marsboom, G., Hong, Z., Salgia, R., Husain, A. N., Wietholt, C., & Archer, S. L. (2012) · The FASEB Journal · doi:10.1096/fj.11-196543 · Cited by 595
Super-Resolution in Medical Imaging
Greenspan, H. (2008) · The Computer Journal · doi:10.1093/comjnl/bxm075 · Cited by 564
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
Fully 3-D PET reconstruction with system matrix derived from point source measurements
Panin, V. Y., Kehren, F., Michel, C., & Casey, M. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.876171 · Cited by 536
“We reconstruct images with an attenuation weighted [20] ordered-subsets expectation maximization (OS-EM) algorithm [21].”
MethodDietary Fats and the Risk of Incident Alzheimer Disease
Morris, M. C., Evans, D. A., Bienias, J. L., Tangney, C. C., Bennett, D. A., Aggarwal, N., Schneider, J., & Wilson, R. S. (2003) · Archives of Neurology · doi:10.1001/archneur.60.2.194 · Cited by 529
Bateman, T. M., Heller, G. V., McGhie, A. I., Friedman, J. D., Case, J. A., Bryngelson, J. R., Hertenstein, G. K., Moutray, K. L., Reid, K., & Cullom, S. J. (2006) · Journal of Nuclear Cardiology · doi:10.1016/j.nuclcard.2005.12.004 · Cited by 527
EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
Hesse, B., Tägil, K., Cuocolo, A., Anagnostopoulos, C., Bardiés, M., Bax, J., Bengel, F., Busemann Sokole, E., Davies, G., Dondi, M., et al. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1779-y · Cited by 527
STIR: software for tomographic image reconstruction release 2
Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/867 · Cited by 466
3D conditional generative adversarial networks for high-quality PET image estimation at low dose
Wang, Y., Yu, B., Wang, L., Zu, C., Lalush, D. S., Lin, W., Wu, X., Zhou, J., Shen, D., & Zhou, L. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.03.045 · Cited by 449
An iterative maximum-likelihood polychromatic algorithm for CT
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959297 · Cited by 430
A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography
Browne, J., & de Pierro, A. B. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538946 · Cited by 424
A gradient-based method for segmenting FDG-PET images: methodology and validation
Geets, X., Lee, J. A., Bol, A., Lonneux, M., & Grégoire, V. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0363-4 · Cited by 419
Dewaraja, Y. K., Frey, E. C., Sgouros, G., Brill, A. B., Roberson, P., Zanzonico, P. B., & Ljungberg, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.100123 · Cited by 419
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Dorbala, S., Ananthasubramaniam, K., Armstrong, I. S., Chareonthaitawee, P., DePuey, E. G., Einstein, A. J., Gropler, R. J., Holly, T. A., Mahmarian, J. J., Park, M.-A., et al. (2018) · Journal of Nuclear Cardiology · doi:10.1007/s12350-018-1283-y · Cited by 406
Fessler, J. A. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.491322 · Cited by 402
(2005) · PubMed · Cited by 395
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Vaquero, J. J., & Kinahan, P. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040723 · Cited by 383
Daisne, J.-F., Sibomana, M., Bol, A., Doumont, T., Lonneux, M., & Grégoire, V. (2003) · Radiotherapy and Oncology · doi:10.1016/s0167-8140(03)00270-6 · Cited by 380
Ljungberg, M., Celler, A., Konijnenberg, M. W., Eckerman, K. F., Dewaraja, Y. K., & Sjögreen-Gleisner, K. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159012 · Cited by 369
Nuyts, J., Dupont, P., Stroobants, S., Benninck, R., Mortelmans, L., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774167 · Cited by 362
Ahn, S., & Fessler, J. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.812251 · Cited by 344
Flotats, A., Carrió, I., Agostini, D., Le Guludec, D., Marcassa, C., Schaffers, M., Somsen, G. A., Unlu, M., & Verberne, H. J. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1491-4 · Cited by 339
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Handbook of Mathematical Methods in Imaging
(2011) · Springer eBooks · doi:10.1007/978-0-387-92920-0 · Cited by 334
Delker, A., Fendler, W. P., Kratochwil, C., Brunegraf, A., Gosewisch, A., Gildehaus, F. J., Tritschler, S., Stief, C. G., Kopka, K., Haberkorn, U., et al. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3174-7 · Cited by 322
Practical considerations for 3-D image reconstruction using spherically symmetric volume elements
Matej, S., & Lewitt, R. M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.481442 · Cited by 314
Image deblurring with Poisson data: from cells to galaxies
Bertero, M., Boccacci, P., Desiderà, G., & Vicidomini, G. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123006 · Cited by 308
Bao, Q., Newport, D., Chen, M., Stout, D. B., & Chatziioannou, A. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056374 · Cited by 306
History and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
Tomographic mammography using a limited number of low‐dose cone‐beam projection images
Wu, T., Stewart, A., Stanton, M., McCauley, T., Phillips, W., Kopans, D. B., Moore, R. H., Eberhard, J. W., Opsahl‐Ong, B., Niklason, L., et al. (2003) · Medical Physics · doi:10.1118/1.1543934 · Cited by 302
Image Reconstruction: From Sparsity to Data-Adaptive Methods and Machine Learning
Ravishankar, S., Ye, J. C., & Fessler, J. A. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2936204 · Cited by 294
Westerterp, M., Pruim, J., Oyen, W., Hoekstra, O., Paans, A., Visser, E., van Lanschot, J., Sloof, G., & Boellaard, R. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0224-1 · Cited by 294
Iterative reconstruction for helical CT: a simulation study
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/003 · Cited by 291
Fast Model-Based X-Ray CT Reconstruction Using Spatially Nonhomogeneous ICD Optimization
Yu, Z., Thibault, J.-B., Bouman, C. A., Sauer, K. D., & Hsieh, J. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2010.2058811 · Cited by 290
Multimodality imaging of structure and function
Townsend, D. W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/4/r01 · Cited by 286
A comparative study of limited‐angle cone‐beam reconstruction methods for breast tomosynthesis
Zhang, Y., Chan, H., Sahiner, B., Wei, J., Goodsitt, M. M., Hadjiiski, L. M., Ge, J., & Zhou, C. (2006) · Medical Physics · doi:10.1118/1.2237543 · Cited by 285
Radioembolization with selective internal radiation microspheres for neuroendocrine liver metastases
King, J., Quinn, R., Glenn, D. M., Janssen, J., Tong, D., Liaw, W., & Morris, D. L. (2008) · Cancer · doi:10.1002/cncr.23685 · Cited by 284
Miller, T. R., & Grigsby, P. W. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02705-0 · Cited by 284
Tang, J., Nett, B. E., & Chen, G.-H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/19/008 · Cited by 282
Dual-Modality Imaging: Combining Anatomy and Function
Townsend, D. W. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.051276 · Cited by 282
Whole-Body18F Dopa PET for Detection of Gastrointestinal Carcinoid Tumors
Hoegerle, S., Altehoefer, C., Ghanem, N., Koehler, G., Waller, C. F., Scheruebl, H., Moser, E., & Nitzsche, E. (2001) · Radiology · doi:10.1148/radiology.220.2.r01au25373 · Cited by 269
Kluge, R., Schmidt, F., Caca, K., Barthel, H., Hesse, S., Georgi, P., Seese, A., Huster, D., & Berr, F. (2001) · Hepatology · doi:10.1053/jhep.2001.23912 · Cited by 265
In vivo small-animal imaging using micro-CT and digital subtraction angiography
Badea, C. T., Drangova, M., Holdsworth, D. W., & Johnson, G. A. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/19/r01 · Cited by 264
Megavoltage CT on a tomotherapy system
Ruchala, K. J., Olivera, G. H., Schloesser, E. A., & Mackie, T. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/10/316 · Cited by 261
A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals
Jeavons, A. P., Chandler, R. A., & Dettmar, C. A. R. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775564 · Cited by 259
Jayson, G. C., Zweit, J., Jackson, A., Mulatero, C., Julyan, P., Ranson, M., Broughton, L., Wagstaff, J., Hakannson, L., Groenewegen, G., et al. (2002) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/94.19.1484 · Cited by 258
Direct reconstruction of kinetic parameter images from dynamic PET data
Kamasak, M. E., Bouman, C. A., Morris, E. D., & Sauer, K. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.845317 · Cited by 254
Zeintl, J., Vija, A. H., Yahil, A., Hornegger, J., & Kuwert, T. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.071571 · Cited by 252
Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
Xu, F., & Mueller, K. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.851398 · Cited by 252
Image-based point spread function implementation in a fully 3D OSEM reconstruction algorithm for PET
Rapisarda, E., Bettinardi, V, Thielemans, K., & Gilardi, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/14/012 · Cited by 142
Microglial activation in healthy aging
Schuitemaker, A., van der Doef, T. F., Boellaard, R., van der Flier, W. M., Yaqub, M., Windhorst, A. D., Barkhof, F., Jonker, C., Kloet, R. W., Lammertsma, A. A., et al. (2012) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2010.09.016 · Cited by 142
Calias, P., Papisov, M., Pan, J., Savioli, N., Belov, V., Huang, Y., Lotterhand, J., Alessandrini, M., Liu, N., Fischman, A. J., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030341 · Cited by 133
“2 mm using a 3-dimensional (3-D) ordered-subset expectation maximization/maximum a posteriori (OSEM3D/MAP) protocol [60], [61] with the hyperparameter b value of 1.”
MethodAssessment of a white matter reference region for 11 C-UCB-J PET quantification
Rossano, S., Toyonaga, T., Finnema, S. J., Naganawa, M., Lu, Y., Nabulsi, N., Ropchan, J., De Bruyn, S., Otoul, C., Stockis, A., et al. (2020) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x19879230 · Cited by 126
“OS-EM is an iterative reconstruction algorithm which is used routinely in PET imaging due to its lower noise compared to filtered backprojection algorithms.(12,17) It has been reported in reconstructions of objects in which a low-radioactivity region is surrounded by a high-radioactivity region with high contrast, OS-…”
MethodTeoh, E. J., McGowan, D. R., Bradley, K. M., Belcher, E., Black, E., & Gleeson, F. V. (2016) · European Radiology · doi:10.1007/s00330-015-3832-y · Cited by 109
Lindström, E., Sundin, A., Trampal, C., Lindsjö, L., Ilan, E., Danfors, T., Antoni, G., Sörensen, J., & Lubberink, M. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.200790 · Cited by 99
Pretorius, P. H., King, M. A., Pan, T.-S., Vries, D. J. D., Glick, S. J., & Byrne, C. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/2/014 · Cited by 72
Xu, W., Xu, F., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.03.018 · Cited by 71
“was similar to that of (Hudson and Larkin, 1994) who devised OS-EM, an ordered subsets algorithm for the Expectation Maximi-”
MethodHigh-performance cone beam reconstruction using CUDA compatible GPUs
Okitsu, Y., Ino, F., & Hagihara, K. (2010) · Parallel Computing · doi:10.1016/j.parco.2010.01.004 · Cited by 70
Howard, B. A., Morgan, R., Thorpe, M. P., Turkington, T. G., Oldan, J., James, O. G., & Borges-Neto, S. (2017) · Annals of Nuclear Medicine · doi:10.1007/s12149-017-1192-1 · Cited by 70
On the efficiency of iterative ordered subset reconstruction algorithms for acceleration on GPUs
Xu, F., Xu, W., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.09.003 · Cited by 63
Clinical evaluation of PET image reconstruction using a spatial resolution model
Andersen, F. L., Klausen, T. L., Loft, A., Beyer, T., & Holm, S. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2012.11.015 · Cited by 62
Kassiou, M., Eberl, S., Meikle, S. R., Birrell, A., Constable, C., Fulham, M. J., Wong, D. F., & Musachio, J. L. (2001) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(00)00206-7 · Cited by 58
He, B., Wahl, R. L., Du, Y., Sgouros, G., Jacene, H., Flinn, I., & Frey, E. C. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.908131 · Cited by 53
“In this work, the reconstructions were performed using the iterative ordered-subsets expectation-maximization (OS-EM) algorithm [37].”
MethodHobbs, R. F., McNutt, T., Baechler, S., He, B., Esaias, C. E., Frey, E. C., Loeb, D. M., Wahl, R. L., Shokek, O., & Sgouros, G. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.08.022 · Cited by 53
Caribé, P. R. R. V., Koole, M., D’Asseler, Y., Van Den Broeck, B., & Vandenberghe, S. (2019) · EJNMMI Physics · doi:10.1186/s40658-019-0264-9 · Cited by 51
Otani, T., Hosono, M., Kanagaki, M., Onishi, Y., Matsubara, N., Kawabata, K., & Kimura, H. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.20478 · Cited by 33
Fin, L., Bailly, P., Daouk, J., & Meyer, M. (2009) · Medical Physics · doi:10.1118/1.3152116 · Cited by 18
Evaluation of in vivo staging of amyloid deposition in cognitively unimpaired elderly aged 78–94
Michalowska, M. M., Herholz, K., Hinz, R., Amadi, C., McInnes, L., Anton-Rodriguez, J. M., Karikari, T. K., Blennow, K., Zetterberg, H., Ashton, N. J., et al. (2022) · Molecular Psychiatry · doi:10.1038/s41380-022-01685-6 · Cited by 11
Fully 3D GPU PET reconstruction
Herraiz, J. L., España, S., Cal-González, J., Vaquero, J. J., Desco, M., & Udías, J. M. (2011) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2010.12.043 · Cited by 10
Metadata
- Authors
- Hudson, H. M., & Larkin, R. S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1994
- Volume
- 13
- Issue
- 4
- Pages
- 601-609
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2154744699
- Cited by
- 3,711
- References
- 14
- FWCI
- 20.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.