The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Abstract
To segment brain tissues in magnetic resonance images of the brain, the authors have implemented a stochastic relaxation method which utilizes partial volume analysis for every brain voxel, and operates on fully three-dimensional (3-D) data. However, there are still problems with automatically or semi-automatically segmenting thick magnetic resonance (MR) slices, particularly when trying to segment the small lesions present in MR images of multiple sclerosis patients. To improve lesion segmentation the authors have extended their method of stochastic relaxation by both pre- and post-processing the MR images. The preprocessing step involves image enhancement using homomorphic filtering to correct for nonhomogeneities in the coil and magnet. Because approximately 95% of all multiple sclerosis lesions occur in the white matter of the brain, the post-processing step involves application of morphological processing and thresholding techniques to the intermediate segmentation in order to develop a mask image containing only white matter and Multiple Sclerosis (MS) lesion. This white/lesion masked image is then segmented by again applying the authors' stochastic relaxation technique. The process has been applied to multispectral MRI scans of multiple sclerosis patients and the results compare favorably to manual segmentations of the same scans obtained independently by radiology health professionals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Statistical Analysis of Dirty Pictures
Besag, J. (1986) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1986.tb01412.x · Cited by 4,191
A survey of thresholding techniques
Sahoo, P. K., Soltani, S., & Wong, A. K. C. (1988) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(88)90022-9 · Cited by 2,662
Brinkmann, K.-D. (1991) · Police Research in the Federal Republic of Germany · doi:10.1007/978-3-642-74176-0_23 · Cited by 2,389
Paty, D. W., Li, D. K. B., the UBC MS/MRI Study Group, & the IFNB Multiple Sclerosis Study Group (1993) · Neurology · doi:10.1212/wnl.43.4.662 · Cited by 1,967
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Moment-preserving thresolding: A new approach
Tsai, W.-H. (1985) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(85)90133-1 · Cited by 909
A comparative performance study of several global thresholding techniques for segmentation
Lee, S. U., Chung, S. Y., & Park, R. (1990) · Computer Vision Graphics and Image Processing · doi:10.1016/0734-189x(90)90053-x · Cited by 631
Three-Dimensional Segmentation of MR Images of the Head Using Probability and Connectivity
Cline, H. E., Lorensen, W. E., Kikinis, R., & Jolesz, F. (1990) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199011000-00041 · Cited by 359
Segmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray Matter
Lim, K. O., & Pfefferbaum, A. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198907000-00006 · Cited by 309
Automatic detection of brain contours in MRI data sets
Brummer, M. E., Mersereau, R. M., Eisner, R. L., & Lewine, R. R. J. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.232244 · Cited by 297
Correction of intensity variations in MR images for computer-aided tissue classification
Dawant, B. M., Zijdenbos, A. P., & Margolin, R. A. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251128 · Cited by 291
Partial volume tissue classification of multichannel magnetic resonance images-a mixel model
Choi, H. S., Haynor, D. R., & Kim, Y. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97590 · Cited by 282
Kohn, M. I., Tanna, N. K., Herman, G. T., Resnick, S. M., Mozley, P. D., Gur, R. E., Alavi, A., Zimmerman, R. A., & Gur, R. C. (1991) · Radiology · doi:10.1148/radiology.178.1.1984289 · Cited by 273
Interactive 3D Segmentation of MRI and CT Volumes using Morphological Operations
Höhne, K. H., & Hanson, W. A. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199203000-00019 · Cited by 259
Intensity correction in surface-coil MR imaging
Axel, L., Costantini, J., & Listerud, J. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.2.418 · Cited by 240
Model-based 3-D segmentation of multiple sclerosis lesions in magnetic resonance brain images
Kamber, M., Shinghal, R., Collins, D. L., Francis, G. S., & Evans, A. C. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414608 · Cited by 211
Volume of Pituitary Macroadenomas: Assessment by MRI
Lundin, P., & Pedersen, F. (1992) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199207000-00004 · Cited by 198
Compensation for surface coil sensitivity variation in magnetic resonance imaging
Narayana, P. A., Brey, W. W., Kulkarni, M. V., & Sievenpiper, C. (1988) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(88)90401-8 · Cited by 131
Magnetic Resonance Imaging in Schizophrenia: I. Volumetric Analysis of Brain and Cerebrospinal Fluid
Gur, R. E., Mozley, P. D., Resnick, S. M., Shtasel, D. L., Kohn, M., Zimmerman, R., Herman, G., Atlas, S., Grossman, R., & Erwin, R. (1991) · Archives of General Psychiatry · doi:10.1001/archpsyc.1991.01810290019002 · Cited by 105
Correction for intensity falloff in surface coil magnetic resonance imaging
Brey, W. W., & Narayana, P. A. (1988) · Medical Physics · doi:10.1118/1.596255 · Cited by 89
An algorithm for compensation of surface-coil images for sensitivity of the surface coil
Haselgrove, J. C., & Prammer, M. G. (1986) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(86)90024-x · Cited by 76
Boundary detection via dynamic programming
Udupa, J. K., Samarasekera, S., & Barrett, W. A. (1992) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.131065 · Cited by 50
Volumes of Chronic Traumatic Frontal Brain Lesions Measured by MR Imaging and CBF Tomography
Maeder, P. P., Wirsén, A., Bajc, M., Schalén, W., Sjöholm, H., Skeidsvoll, H., Cronqvist, S., & Ingvar, D. H. (1991) · Acta Radiologica · doi:10.1177/028418519103200402 · Cited by 6
MR Image Non-uneformity Correction Techniques
Glennon, D. T., Clarke, L. P., Velthuizen, R. P., & Silbiger, M. L. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1991.683854 · Cited by 6
Cited by
A modified fuzzy c-means algorithm for bias field estimation and segmentation of MRI data
Ahmed, M. N., Yamany, S. M., Mohamed, N., Farag, A. A., & Moriarty, T. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.996338 · Cited by 1,792
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Adaptive fuzzy segmentation of magnetic resonance images
Pham, D. L., & Prince, J. L. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.802752 · Cited by 805
A novel kernelized fuzzy C-means algorithm with application in medical image segmentation
Zhang, D.-Q., & Chen, S.-C. (2004) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2004.01.012 · Cited by 544
Automated segmentation of multiple sclerosis lesions by model outlier detection
Van Leemput, K., Maes, F., Vandermeulen, D., Colchester, A., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.938237 · Cited by 489
Metadata
- Authors
- Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1996-04
- Volume
- 15
- Issue
- 2
- Pages
- 154-169
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2064819030
- Cited by
- 260
- References
- 24
- FWCI
- 16.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.