Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 516

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

A surface-based technique for warping three-dimensional images of the brain

Thompson, P., Toga, A.W.·1996·IEEE Transactions on Medical Imaging

Abstract

The authors have devised, implemented, and tested a fast, spatially accurate technique for calculating the high-dimensional deformation field relating the brain anatomies of an arbitrary pair of subjects. The resulting three-dimensional (3-D) deformation map can be used to quantify anatomic differences between subjects or within the same subject over time and to transfer functional information between subjects or integrate that information on a single anatomic template. The new procedure is based on developmental processes responsible for variations in normal human anatomy and is applicable to 3-D brain images in general, regardless of modality. Hybrid surface models known as Chen surfaces (based on superquadrics and spherical harmonics) are used to efficiently initialize 3-D active surfaces, and these then extract from both scans the developmentally fundamental surfaces of the ventricles and cortex. The construction of extremely complex surface deformation maps on the internal cortex is made easier by building a generic surface structure to model it. Connected systems of parametric meshes model several deep sulci whose trajectories represent critical functional boundaries. These sulci are sufficiently extended inside the brain to reflect subtle and distributed variations in neuroanatomy between subjects. The algorithm then calculates the high-dimensional volumetric warp (typically with 3842x256x3 approximately 0.1 billion degrees of freedom) deforming one 3-D scan into structural correspondence with the other. Integral distortion functions are used to extend the deformation field required to elastically transform nested surfaces to their counterparts in the target scan. The algorithm's accuracy is tested, by warping 3-D magnetic resonance imaging (MRI) volumes from normal subjects and Alzheimer's patients, and by warping full-color 1024(3 ) digital cryosection volumes of the human head onto MRI volumes. Applications are discussed, including the transfer of multisubject 3-D functional, vascular, and histologic maps onto a single anatomic template; the mapping of 3-D brain atlases onto the scans of new subjects; and the rapid detection, quantification, and mapping of local shape changes in 3-D medical images in disease and during normal or abnormal growth and development.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.511745

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 516

Metadata

Authors
Thompson, P., & Toga, A. W.
Venue
IEEE Transactions on Medical Imaging
Published
1996
Volume
15
Issue
4
Pages
402-417
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2143736779
Cited by
516
References
3
FWCI
38.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.