CoChat

Accurate measurement of intrathoracic airways

Reinhardt, J.M., D'Souza, N., Hoffman, E.A. · 1997 · IEEE Transactions on Medical Imaging
Cited by 176

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Airway geometry measurements can provide information regarding pulmonary physiology and pathophysiology. There has been considerable interest in measuring intrathoracic airways in two-dimensional (2-D) slices from volumetric X-ray computed tomography (CT). Such measurements can be used to evaluate and track the progression of diseases affecting the airways. A popular airway measurement method uses the "half-max" criteria, in which the gray level at the airway wall is estimated to be halfway between the minimum and maximum gray levels along a ray crossing the edge. However, because the scanning process introduces blurring, the half-max approach may not be applicable across all airway sizes. We propose a new measurement method based on a model of the scanning process. In our approach, we examine the gray-level profile of a ray crossing the airway wall and use a maximum-likelihood method to estimate the airway inner and outer radius. Using CT scans of a physical phantom, we present results showing that the new approach is more accurate than the half-max method at estimating wall location for thin-walled airways.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/42.650878

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 176

Metadata

Authors
Reinhardt, J. M., D'Souza, N., & Hoffman, E. A.
Venue
IEEE Transactions on Medical Imaging
Published
1997
Volume
16
Issue
6
Pages
820-827
ISSN
0278-0062 (ISSN-L)
OpenAlex
W2150398959
Cited by
176
References
16
FWCI
1.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.