The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Coronary Artery Dimensions from Cineangiograms-Methodology and Validation of a Computer-Assisted Analysis Procedure
Abstract
To evaluate the efficacy of modern therapeutic procedures in the catheterization laboratory, the effects of vasoactive drugs, as well as the effects of short and long term interventions on the regression or progression of coronary artery disease, an objective and reproducible technique for the assessment of coronary artery dimensions was developed. This paper describes the methodology of such a computer-assisted analysis system, as well as the results from a validation study on the accuracy and precision. A region in a 35 mm cineframe encompassing a selected arterial segment is optically magnified and converted into video format by means of a specially constructed cinevideo converter and digitized for subsequent analysis by computer. Contours of the arterial segment are detected automatically on the basis of first and second derivative functions. Contour data are corrected for pincushion distortion; arterial dimensions are presented in mm, where the calibration factor is derived from a computer-processed segment of the contrast catheter. The accuracy and precision of the edge detection procedure as assessed from cinefilms of perspex models (%-D stenosis =/<70 percent) filled with contrast agent were -30 and 90 mum, respectively. The variablity of the analysis procedure by itself in terms of absolute arterial dimensions was less than 0.12 mm, and in terms of percentage arterial narrowing for coronary obstructions less than 2.74 percent. It is concluded that this system allows the measurement of coronary arterial dimensions in an objective and highly reproducible way.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reiber, J. H., Serruys, P. W., Kooijman, C. J., Wijns, W., Slager, C. J., Gerbrands, J. J., Schuurbiers, J. C., den Boer, A., & Hugenholtz, P. G. (1985) · Circulation · doi:10.1161/01.cir.71.2.280 · Cited by 829
Self-citationInterobserver variability in coronary angiography.
Zir, L. M., Miller, S. W., Dinsmore, R. E., Gilbert, J. P., & Harthorne, J. W. (1976) · Circulation · doi:10.1161/01.cir.53.4.627 · Cited by 768
Brown, B. G., Bolson, E., Frimer, M., & Dodge, H. T. (1977) · Circulation · doi:10.1161/01.cir.55.2.329 · Cited by 633
Variability in the analysis of coronary arteriograms.
DeRouen, T. A., Murray, J. A., & Owen, W. (1977) · Circulation · doi:10.1161/01.cir.55.2.324 · Cited by 485
Observer agreement in evaluating coronary angiograms.
Detre, K. M., Wright, E., Murphy, M. L., & Takaro, T. (1975) · Circulation · doi:10.1161/01.cir.52.6.979 · Cited by 447
Serruys, P. W., Wijns, W., van den Brand, M., Ribeiro, V, Fioretti, P., Simoons, M. L., Kooijman, C. J., Reiber, J. H., & Hugenholtz, P. G. (1983) · Heart · doi:10.1136/hrt.50.3.257 · Cited by 192
Self-citationHuman Coronary Artery Size During Life
MacAlpin, R. N., Abbasi, A. S., Grollman, J. H., et al. (1973) · Radiology · doi:10.1148/108.3.567 · Cited by 152
Reproducibility of a consensus panel in the interpretation of coronary angiograms
Sanmarco, M. E., Brooks, S. H., & Blankenhorn, D. H. (1978) · American Heart Journal · doi:10.1016/0002-8703(78)90151-5 · Cited by 137
Dw, C., Sh, B., Selzer, R. H., Barndt, R., Es, B., & Blankenhorn, D. H. (1977) · PubMed · Cited by 82
Cine‐densitometric measurement of coronary arterial stenoses
Sándor, T., Als, A. V., & Paulin, S. J. (1979) · Catheterization and Cardiovascular Diagnosis · doi:10.1002/ccd.1810050304 · Cited by 81
Cited by
Platelet Glycoprotein IIb/IIIa Inhibition with Coronary Stenting for Acute Myocardial Infarction
Montalescot, G., Barragan, P., Wittenberg, O., Ecollan, P., Elhadad, S., Villain, P., Boulenc, J.-M., Morice, M.-C., Maillard, L., Pansiéri, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200106213442503 · Cited by 1,186
Reiber, J. H., Serruys, P. W., Kooijman, C. J., Wijns, W., Slager, C. J., Gerbrands, J. J., Schuurbiers, J. C., den Boer, A., & Hugenholtz, P. G. (1985) · Circulation · doi:10.1161/01.cir.71.2.280 · Cited by 829
Self-citationSchwartz, L., Bourassa, M. G., Lespérance, J., Aldridge, H. E., Kazim, F., Salvatori, V. A., Henderson, M., Bonan, R., & David, P. R. (1988) · New England Journal of Medicine · doi:10.1056/nejm198806303182603 · Cited by 692
Douglas, P. S., Pontone, G., Hlatky, M. A., Patel, M. R., Norgaard, B. L., Byrne, R. A., Curzen, N., Purcell, I., Gutberlet, M., Rioufol, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv444 · Cited by 579
Dehmer, G. J., Popma, J. J., van den Berg, E. K., Eichhorn, E. J., Prewitt, J. B., Campbell, W. B., Jennings, L., Willerson, J. T., & Schmitz, J. M. (1988) · New England Journal of Medicine · doi:10.1056/nejm198809223191201 · Cited by 379
Metadata
- Authors
- Reiber, J. H. C., Kooijman, C. J., Slager, C. J., Gerbrands, J. J., Schuurbiers, J. C. H., Den Boer, A., Wijns, W., Serruys, P. W., & Hugenholtz, P. G.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1984-09
- Volume
- 3
- Issue
- 3
- Pages
- 131-141
- ISSN
- 0278-0062 (ISSN-L)
- 1558-254X
- OpenAlex
- W2062128472
- Cited by
- 253
- References
- 11
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary Artery Dimensions from Cineangiograms-Methodology and Validation of a Computer-Assisted Analysis Procedure. https://app.cochat.ai/papers/10.1109/tmi.1984.4307669
- The paper
- Reiber, J. H. C., Kooijman, C. J., Slager, C. J., Gerbrands, J. J., Schuurbiers, J. C. H., Den Boer, A., Wijns, W., Serruys, P. W., & Hugenholtz, P. G. (1984). Coronary Artery Dimensions from Cineangiograms-Methodology and Validation of a Computer-Assisted Analysis Procedure. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.1984.4307669
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.