The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion
Abstract
We present the use of an entropy focus criterion to enable automatic focusing of motion corrupted magnetic resonance images. We demonstrate the principle using illustrative examples from cooperative volunteers. Our technique can determine unknown patient motion or use knowledge of motion from other measures as a starting estimate. The motion estimate is used to compensate the acquired data and is iteratively refined using the image entropy. Entropy focuses the whole image principally by favoring the removal of motion induced ghosts and blurring from otherwise dark regions of the image. Using only the image data, and no special hardware or pulse sequences, we demonstrate correction for arbitrary rigid-body translational motion in the imaging plane and for a single rotation. Extension to three-dimensional (3-D) and more general motion should be possible. The algorithm is able to determine volunteer motion well. The mean absolute deviation between algorithm and navigator-echo-determined motion is comparable to the displacement step size used in the algorithm. Local deviations from the recorded motion or navigator-determined motion are explained and we indicate how enhanced focus criteria may be derived. In all cases we were able to compensate images for patient motion, reducing blurring and ghosting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jackson, J. I., Meyer, C. H., Nishimura, D. G., & Macovski, A. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.97598 · Cited by 1,059
Image reconstruction from incomplete and noisy data
Gull, S. F., & Daniell, G. J. (1978) · Nature · doi:10.1038/272686a0 · Cited by 965
Comparison of Interpolating Methods for Image Resampling
Parker, J. A., Kenyon, R. V., & Troxel, D. E. (1983) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1983.4307610 · Cited by 829
Adaptive technique for high-definition MR imaging of moving structures.
Ehman, R. L., & Felmlee, J. P. (1989) · Radiology · doi:10.1148/radiology.173.1.2781017 · Cited by 801
Projection Reconstruction Techniques for Reduction of Motion Effects in MRI
Glover, G. H., & Pauly, J. M. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280209 · Cited by 563
Diffusion‐weighted interleaved echo‐planar imaging with a pair of orthogonal navigator echoes
Butts, K., de Crespigny, A., Pauly, J. M., & Moseley, M. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350518 · Cited by 244
Deblurring for non‐2D fourier transform magnetic resonance imaging
Noll, D. C., Pauly, J. M., Meyer, C. H., Nishimura, D. G., & Macovskj, A. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250210 · Cited by 222
Cited by
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
MRIQC: Advancing the automatic prediction of image quality in MRI from unseen sites
Esteban, O., Birman, D., Schaer, M., Koyejo, O. O., Poldrack, R. A., & Gorgolewski, K. J. (2017) · PLOS ONE · doi:10.1371/journal.pone.0184661 · Cited by 920
Enhancing studies of the connectome in autism using the autism brain imaging data exchange II
Di Martino, A., O’Connor, D., Chen, B., Alaerts, K., Anderson, J. S., Assaf, M., Balsters, J. H., Baxter, L., Beggiato, A., Bernaerts, S., et al. (2017) · Scientific Data · doi:10.1038/sdata.2017.10 · Cited by 710
An open resource for transdiagnostic research in pediatric mental health and learning disorders
Alexander, L. M., Escalera, J., Ai, L., Andreotti, C., Febre, K., Mangone, A., Vega-Potler, N., Langer, N., Alexander, A., Kovacs, M., et al. (2017) · Scientific Data · doi:10.1038/sdata.2017.181 · Cited by 651
Tisdall, M. D., Hess, A. T., Reuter, M., Meintjes, E. M., Fischl, B., & van der Kouwe, A. J. W. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23228 · Cited by 443
Metadata
- Authors
- Atkinson, D., Hill, D. L. G., Stoyle, P. N. R., Summers, P. E., & Keevil, S. F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1997
- Volume
- 16
- Issue
- 6
- Pages
- 903-910
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2104434712
- Cited by
- 282
- References
- 7
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.