The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Maximum-likelihood estimation of Rician distribution parameters
Abstract
The problem of parameter estimation from Rician distributed data (e.g., magnitude magnetic resonance images) is addressed. The properties of conventional estimation methods are discussed and compared to maximum-likelihood (ML) estimation which is known to yield optimal results asymptotically. In contrast to previously proposed methods, ML estimation is demonstrated to be unbiased for high signal-to-noise ratio (SNR) and to yield physical relevant results for low SNR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability, Random Variables, and Stochastic Processes.
Abrahams, J., & Papoulis, A. (1984) · Journal of the American Statistical Association · doi:10.2307/2288754 · Cited by 16,226
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Mathematical Analysis of Random Noise
Rice, S. O. (1944) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1944.tb00874.x · Cited by 5,480
Probability, random variables and stochastic processes
Proakis, J. (1985) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1985.1164715 · Cited by 4,568
Kendall's Advanced Theory of Statistics.
AA, Stuart, A., & Ord, K. (1995) · Journal of the American Statistical Association · doi:10.2307/2291187 · Cited by 2,619
The rician distribution of noisy mri data
Gudbjartsson, H., & Patz, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340618 · Cited by 2,494
Catastrophe Theory and Its Applications
Poston, T., Stewart, I., & Plaut, R. H. (1979) · Journal of Applied Mechanics · doi:10.1115/1.3424591 · Cited by 2,085
Nonlinear anisotropic filtering of MRI data
Gerig, G., Kubler, O., Kikinis, R., & Jolesz, F. A. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141646 · Cited by 1,149
Measurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Measuring signal-to-noise ratios in MR imaging.
Kaufman, L., Kramer, D. M., Crooks, L. E., & Ortendahl, D. A. (1989) · Radiology · doi:10.1148/radiology.173.1.2781018 · Cited by 360
Estimation of the Noise in Magnitude MR Images
Sijbers, J., den Dekker, A. J., Van Audekerke, J., Verhoye, M., & Van Dyck, D. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00199-9 · Cited by 277
Self-citationThe use of power images to perform quantitative analysis on low SNR MR images
Miller, A. J., & Joseph, P. M. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90225-3 · Cited by 244
An unbiased signal‐to‐noise ratio measure for magnetic resonance images
McGibney, G., & Smith, M. R. (1993) · Medical Physics · doi:10.1118/1.597004 · Cited by 194
Analysis of noise in phase contrast MR imaging
Andersen, A. H., & Kirsch, J. E. (1996) · Medical Physics · doi:10.1118/1.597729 · Cited by 96
Signal-to-noise measures for magnetic resonance imagers
Murphy, B. W., Carson, P. L., Ellis, J. H., Zhang, Y. T., Hyde, R. J., & Chenevert, T. L. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90076-p · Cited by 86
Statistical analysis of MR imaging and its applications in image modeling
Wang, Y., & Lei, T. (2002) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.1994.413438 · Cited by 41
Cited by
Ultrasound image segmentation: a survey
Noble, J. A., & Boukerroui, D. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.877092 · Cited by 1,157
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Diffusion MRI noise mapping using random matrix theory
Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26059 · Cited by 773
Veraart, J., Sijbers, J., Sunaert, S., Leemans, A., & Jeurissen, B. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.028 · Cited by 504
Self-citationWhat can we see with IVIM MRI?
Le Bihan, D. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.062 · Cited by 498
Metadata
- Authors
- Sijbers, J., den Dekker, A. J., Scheunders, P., & Van Dyck, D.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1998-06
- Volume
- 17
- Issue
- 3
- Pages
- 357-361
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2151952539
- Cited by
- 393
- References
- 16
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.