The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A reappraisal of the use of infrared thermal image analysis in medicine
Abstract
Infrared thermal imaging of the skin has been used for several decades to monitor the temperature distribution of human skin. Abnormalities such as malignancies, inflammation, and infection cause localized increases in temperature which show as hot spots or as asymmetrical patterns in an infrared thermogram. Even though it is nonspecific, infrared thermology is a powerful detector of problems that affect a patient's physiology. While the use of infrared imaging is increasing in many industrial and security applications, it has declined in medicine probably because of the continued reliance on first generation cameras. The transfer of military technology for medical use has prompted this reappraisal of infrared thermology in medicine. Digital infrared cameras have much improved spatial and thermal resolutions, and libraries of image processing routines are available to analyze images captured both statically and dynamically. If thermographs are captured under controlled conditions, they may be interpreted readily to diagnose certain conditions and to monitor the reaction of a patient's physiology to thermal and other stresses. Some of the major areas where infrared thermography is being used successfully are neurology, vascular disorders, rheumatic diseases, tissue viability, oncology (especially breast cancer), dermatological disorders, neonatal, ophthalmology, and surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spectral emissivity of skin and pericardium
Steketee, J. (1973) · Physics in Medicine & Biology · doi:10.1088/0031-9155/18/5/307 · Cited by 429
Houdas, Y., & Ring, E. F. J. (1982) · Springer eBooks · doi:10.1007/978-1-4899-0345-7 · Cited by 199
Symmetry of Skin Temperature Comparing One Side of the Body to the other
Uematsu, S. (1985) · Cited by 112
Quantitative Dynamic Telethermometry in Medical Diagnosis and Management
Anbar, M. (1994) · Medical Entomology and Zoology · Cited by 63
Cited by
Terahertz Technology in Biology and Medicine
Siegel, P. H. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.835916 · Cited by 1,378
Medical applications of infrared thermography: A review
Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J. (2012) · Infrared Physics & Technology · doi:10.1016/j.infrared.2012.03.007 · Cited by 1,333
Infrared Thermography for Temperature Measurement and Non-Destructive Testing
Usamentiaga, R., Venegas, P., Guerediaga, J., Vega, L., Molleda, J., & Bulnes, F. (2014) · Sensors · doi:10.3390/s140712305 · Cited by 1,181
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
Infrared thermography: A non-invasive window into thermal physiology
Tattersall, G. J. (2016) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/j.cbpa.2016.02.022 · Cited by 398
In Vivo Luminescence Nanothermometry: from Materials to Applications
del Rosal, B., Ximendes, E., Rocha, U., & Jaque, D. (2017) · Advanced Optical Materials · doi:10.1002/adom.201600508 · Cited by 331
Arora, N., Martins, D., Ruggerio, D., Tousimis, E., Swistel, A. J., Osborne, M. P., & Simmons, R. M. (2008) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2008.06.015 · Cited by 320
Digital infrared thermal imaging of human skin
Jones, B. F., & Plassmann, P. (2002) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2002.1175137 · Cited by 287
Self-citationA perspective on medical infrared imaging
Jiang, L. J., Ng, E. Y. K., Yeo, A. C. B., Wu, S., Pan, F., Yau, W. Y., Chen, J. H., & Yang, Y. (2005) · Journal of Medical Engineering & Technology · doi:10.1080/03091900512331333158 · Cited by 283
A Comparative Review of Thermography as a Breast Cancer Screening Technique
Kennedy, D. A., Lee, T., & Seely, D. (2009) · Integrative Cancer Therapies · doi:10.1177/1534735408326171 · Cited by 283
Khandakar, A., Chowdhury, M. E. H., Reaz, M. B. I., Ali, S. H. M., Kiranyaz, S., Rahman, T., Chowdhury, M. H., Ayari, M. A., Alfkey, R., Bakar, A. A. A., et al. (2022) · Sensors · doi:10.3390/s22114249 · Cited by 74
The experiment study on infrared radiation spectrum of human body
Yu, W. L., Wang, Z., & Jin, L. (2012) · Proceedings of 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics · doi:10.1109/bhi.2012.6211692 · Cited by 9
Metadata
- Authors
- Jones, B. F.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1998
- Volume
- 17
- Issue
- 6
- Pages
- 1019-1027
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2133643452
- Cited by
- 572
- References
- 4
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.