Model-based quantitation of 3-D magnetic resonance angiographic images
Abstract
Quantification of the degree of stenosis or vessel dimensions are important for diagnosis of vascular diseases and planning vascular interventions. Although diagnosis from three-dimensional (3-D) magnetic resonance angiograms (MRA's) is mainly performed on two-dimensional (2-D) maximum intensity projections, automated quantification of vascular segments directly from the 3-D dataset is desirable to provide accurate and objective measurements of the 3-D anatomy. A model-based method for quantitative 3-D MRA is proposed. Linear vessel segments are modeled with a central vessel axis curve coupled to a vessel wall surface. A novel image feature to guide the deformation of the central vessel axis is introduced. Subsequently, concepts of deformable models are combined with knowledge of the physics of the acquisition technique to accurately segment the vessel wall and compute the vessel diameter and other geometrical properties. The method is illustrated and validated on a carotid bifurcation phantom, with ground truth and medical experts as comparisons. Also, results on 3-D time-of-flight (TOF) MRA images of the carotids are shown. The approach is a promising technique to assess several geometrical vascular parameters directly on the source 3-D images, providing an objective mechanism for stenosis grading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Kass, M., Witkin, A., & Terzopoulos, D. (1988) · International Journal of Computer Vision · doi:10.1007/bf00133570 · Cited by 17,070
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Multiscale vessel enhancement filtering
Frangi, A. F., Niessen, W. J., Vincken, K. L., & Viergever, M. A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056195 · Cited by 3,707
Self-citationFeature detection with automatic scale selection
Lindeberg, T. (1998) · International Journal of Computer Vision · doi:10.1023/a:1008045108935 · Cited by 2,541
Koenderink, J. J. (1984) · Biological Cybernetics · doi:10.1007/bf00336961 · Cited by 2,452
Curves and Surfaces for Computer Aided Geometric Design--A Practical Guide.
Bajaj, C., & Farin, G. (1990) · Mathematics of Computation · doi:10.2307/2008458 · Cited by 2,123
The North American Symptomatic Carotid Endarterectomy Trial: Surgical Results in 1415 Patients
Ferguson, G. G., Eliasziw, M., Barr, H. W. K., Clagett, G. P., Barnes, R. W., Wallace, M. C., Taylor, D. W., Haynes, R. B., Finan, J. W., Hachinski, V. C., et al. (1999) · Stroke · doi:10.1161/01.str.30.9.1751 · Cited by 1,503
An unbiased detector of curvilinear structures
Steger, C. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.659930 · Cited by 1,392
Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Gerig, G., & Kikinis, R. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80009-1 · Cited by 1,163
(1991) · Stroke · doi:10.1161/01.str.22.6.711 · Cited by 1,133
Constraints on deformable models:Recovering 3D shape and nonrigid motion
Terzopoulos, D., Witkin, A., & Kass, M. (1988) · Artificial Intelligence · doi:10.1016/0004-3702(88)90080-x · Cited by 774
Curves and surfaces for computer aided geometric design: a practical guide
(1989) · Choice Reviews Online · doi:10.5860/choice.27-0348 · Cited by 444
Model-Based Detection of Tubular Structures in 3D Images
Krissian, K., Malandain, G., Ayache, N., Vaillant, R., & Trousset, Y. (2000) · Computer Vision and Image Understanding · doi:10.1006/cviu.2000.0866 · Cited by 404
Sato, Y., Nakajima, S., Atsumi, H., Koller, T., Gerig, G., Yoshida, S., & Kikinis, R. (1997) · Lecture Notes in Computer Science · doi:10.1007/bfb0029240 · Cited by 396
Scale and the differential structure of images
Florack, L. M. J., ter Haar Romeny, B. M., Koenderink, J. J., & Viergever, M. A. (1992) · Image and Vision Computing · doi:10.1016/0262-8856(92)90024-w · Cited by 382
Self-citationMultiscale detection of curvilinear structures in 2-D and 3-D image data
Koller, T. M., Gerig, G., Szekely, G., & Dettwiler, D. (2002) · Proceedings of IEEE International Conference on Computer Vision · doi:10.1109/iccv.1995.466846 · Cited by 314
Lorenz, C., Carlsen, I. C., Buzug, T. M., Fassnacht, C., & Weese, J. (1997) · Lecture Notes in Computer Science · doi:10.1007/bfb0029242 · Cited by 283
Du, Y. P., Parker, D. L., Davis, W. L., & Cao, G. (1994) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880040517 · Cited by 216
Limits to the accuracy of vessel diameter measurement in MR angiography
Hoogeveen, R. M., Bakker, C. J. G., & Viergever, M. A. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080608 · Cited by 186
Self-citationQuantitative coronary angiography with deformable spline models
Klein, A. K., Lee, F., & Amini, A. A. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640737 · Cited by 140
Pan, X. M., Saloner, D., Reilly, L. M., Bowersox, J. C., Murray, S. P., Anderson, C. M., Gooding, G. A. W., & Rapp, J. H. (1995) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(95)70246-6 · Cited by 140
An algorithm for real-time vessel enhancement and detection
Poli, R., & Valli, G. (1997) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(96)01773-7 · Cited by 109
Image reconstruction by convolution with symmetrical piecewise nth-order polynomial kernels
Meijering, E. H. W., Zuiderveld, K. J., & Viergever, M. A. (1999) · IEEE Transactions on Image Processing · doi:10.1109/83.743854 · Cited by 106
Self-citationGeometric characterization of stenosed human carotid arteries
Smith, R. F., Rutt, B. K., Fox, A. J., & Rankin, R. N. (1996) · Academic Radiology · doi:10.1016/s1076-6332(96)80297-2 · Cited by 91
Elgersma, O. E. H., Buijs, P. C., Wüst, A. F. J., van der Graaf, Y., Eikelboom, B. C., & Mali, W. P. T. M. (1999) · Radiology · doi:10.1148/radiology.213.3.r99nv03777 · Cited by 80
Cited by
Deep Learning‐Based Crack Damage Detection Using Convolutional Neural Networks
Cha, Y., Choi, W., & Büyüköztürk, O. (2017) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12263 · Cited by 3,295
Design and validation of a tool for neurite tracing and analysis in fluorescence microscopy images
Meijering, E., Jacob, M., Sarria, J. ‐. F., Steiner, P., Hirling, H., & Unser, M. (2004) · Cytometry Part A · doi:10.1002/cyto.a.20022 · Cited by 1,608
A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes
Lesage, D., Angelini, E. D., Bloch, I., & Funka-Lea, G. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.011 · Cited by 920
Computer vision-based concrete crack detection using U-net fully convolutional networks
Liu, Z., Cao, Y., Wang, Y., & Wang, W. (2019) · Automation in Construction · doi:10.1016/j.autcon.2019.04.005 · Cited by 833
Aylward, S. R., & Bullitt, E. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/42.993126 · Cited by 578
Metadata
- Authors
- Frangi, A. F., Niessen, W. J., Hoogeveen, R. M., van Walsum, T., & Viergever, M. A.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 1999
- Volume
- 18
- Issue
- 10
- Pages
- 946-956
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2101632303
- Cited by
- 383
- References
- 29
- FWCI
- 11.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.