The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images
Abstract
Ultrasonic measurements of human carotid and femoral artery walls are conventionally obtained by manually tracing interfaces between tissue layers. The drawbacks of this method are the interobserver variability and inefficiency. In this paper, we present a new automated method which reduces these problems. By applying a multiscale dynamic programming (DP) algorithm, approximate vessel wall positions are first estimated in a coarse-scale image, which then guide the detection of the boundaries in a fine-scale image. In both cases, DP is used for finding a global optimum for a cost function. The cost function is a weighted sum of terms, in fuzzy expression forms, representing image features and geometrical characteristics of the vessel interfaces. The weights are adjusted by a training procedure using human expert tracings. Operator interventions, if needed, also take effect under the framework of global optimality. This reduces the amount of human intervention and, hence, variability due to subjectiveness. By incorporating human knowledge and experience, the algorithm becomes more robust. A thorough evaluation of the method in the clinical environment shows that interobserver variability is evidently decreased and so is the overall analysis time. We conclude that the automated procedure can replace the manual procedure and leads to an improved performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of digital image processing
Jain, A. K. (1988) · Cited by 7,111
Fundamentals of digital image processing
(1989) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(89)90041-8 · Cited by 4,677
A review on image segmentation techniques
Pal, N. R., & Pal, S. K. (1993) · Pattern Recognition · doi:10.1016/0031-3203(93)90135-j · Cited by 3,708
Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging.
Pignoli, P., Tremoli, E., Poli, A., Oreste, P., & Paoletti, R. (1986) · Circulation · doi:10.1161/01.cir.74.6.1399 · Cited by 2,404
Witkin, A. P. (1987) · Readings in Computer Vision · doi:10.1016/b978-0-08-051581-6.50036-2 · Cited by 2,359
Bellman, R. E., & Dreyfus, S. E. (1962) · Princeton University Press eBooks · doi:10.1515/9781400874651 · Cited by 1,971
Fuzzy Sets and their Applications to Cognitive and Decision Processes
(1975) · Elsevier eBooks · doi:10.1016/c2013-0-11734-5 · Cited by 1,212
Scale-space filtering: A new approach to multi-scale description
Witkin, A. (2005) · ICASSP '84. IEEE International Conference on Acoustics, Speech, and Signal Processing · doi:10.1109/icassp.1984.1172729 · Cited by 1,086
Introduction to the Theory of Fuzzy Subsets.
Proctor, C. H., Kaufman, A., & Swanson, D. L. (1977) · Journal of the American Statistical Association · doi:10.2307/2286947 · Cited by 1,062
Using dynamic programming for solving variational problems in vision
Amini, A. A., Weymouth, T. E., & Jain, R. C. (1990) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.57681 · Cited by 1,008
Uniqueness of the Gaussian Kernel for Scale-Space Filtering
Babaud, J., Witkin, A. P., Baudin, M., & Duda, R. O. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767749 · Cited by 804
Ultrasound B-mode imaging in observational studies of atherosclerotic progression.
SALONEN, J. T., & Salonen, R. M. (1993) · PubMed · Cited by 783
Scaling Theorems for Zero Crossings
Yuille, A. L., & Poggio, T. A. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767748 · Cited by 626
Wendelhag, I., Gustavsson, T., Suurküla, M., Berglund, G., & Wikstrand, J. (1991) · Clinical Physiology · doi:10.1111/j.1475-097x.1991.tb00676.x · Cited by 515
Self-citationWendelhag, I., Liang, Q., Gustavsson, T., & Wikstrand, J. (1997) · Stroke · doi:10.1161/01.str.28.11.2195 · Cited by 375
Self-citationWong, M., Edelstein, J., Wollman, J., & Bond, M. G. (1993) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.13.4.482 · Cited by 325
Selzer, R. H., Hodis, H. N., Kwong-Fu, H., Mack, W. J., Lee, P. L., Liu, C.-R., & Liu, C.-H. (1994) · Atherosclerosis · doi:10.1016/0021-9150(94)90186-4 · Cited by 300
Ultrasound-determined intima-media thickness and atherosclerosis. Direct and indirect validation.
Persson, J., Formgren, J., Israelsson, B., & Berglund, G. (1994) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.14.2.261 · Cited by 238
A model of attention-guided visual perception and recognition
Rybak, I. A., Gusakova, V. I., Golovan, A. V., Podladchikova, L. N., & Shevtsova, N. A. (1998) · Vision Research · doi:10.1016/s0042-6989(98)00020-0 · Cited by 220
Use of monitoring software to improve the measurement of carotid wall thickness by B-mode imaging
Touboul, P.-J., Prati, P., Scarabin, P.-Y., Adrai, V., Thibout, E., & Ducimetière, P. (1992) · Journal of Hypertension · doi:10.1097/00004872-199207001-00006 · Cited by 186
Gariepy, J., Massonneau, M., Levenson, J., Heudes, D., & Simon, A. (1993) · Hypertension · doi:10.1161/01.hyp.22.1.111 · Cited by 167
On the Role of the Observer and a Distortion Measure in Image Transmission
Sakrison, D. (1977) · IEEE Transactions on Communications · doi:10.1109/tcom.1977.1093773 · Cited by 123
Stensland-Bugge, E., Bønaa, K. H., & Joakimsen, O. (1997) · Stroke · doi:10.1161/01.str.28.10.1972 · Cited by 122
Schmidt, F., & Wendelhag (1999) · Clinical Physiology · doi:10.1046/j.1365-2281.1999.00145.x · Cited by 112
On Quantifying Plaque Size and Intima-Media Thickness in Carotid and Femoral Arteries
Wendelhag, I., Wiklund, O., & Wikstrand, J. (1996) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.16.7.843 · Cited by 90
Self-citationEvolving Concepts of Spatial Channels in Vision: From Independence to Nonlinear Interactions
Wilson, H. R., & Wilkinson, F. E. (1997) · Perception · doi:10.1068/p260939 · Cited by 54
Gustavsson, T., Rafeef Abugharbieh, A., Hamarneh, G., & Liang, Q. (1997) · Computers in cardiology · doi:10.1109/cic.1997.647832 · Cited by 44
Self-citation
Cited by
Effect of Torcetrapib on Carotid Atherosclerosis in Familial Hypercholesterolemia
Kastelein, J. J. P., van Leuven, S. I., Burgess, L., Evans, G. W., Kuivenhoven, J. A., Barter, P. J., Revkin, J. H., Grobbee, D. E., Riley, W. A., Shear, C. L., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071359 · Cited by 658
Improved analysis of brachial artery ultrasound using a novel edge-detection software system
Woodman, R. J., Playford, D. A., Watts, G. F., Cheetham, C., Reed, C., Taylor, R. R., Puddey, I. B., Beilin, L. J., Burke, V., Mori, T. A., et al. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.929 · Cited by 533
Bots, M. L., Visseren, F. L., Evans, G. W., Riley, W. A., Revkin, J. H., Tegeler, C. H., Shear, C. L., Duggan, W. T., Vicari, R. M., Grobbee, D. E., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61088-5 · Cited by 461
Bots, M. L., Evans, G. W., Riley, W. A., & Grobbee, D. E. (2003) · Stroke · doi:10.1161/01.str.0000102044.27905.b5 · Cited by 379
Endogenous Sex Hormones and Progression of Carotid Atherosclerosis in Elderly Men
Muller, M., van den Beld, A. W., Bots, M. L., Grobbee, D. E., Lamberts, S. W. J., & van der Schouw, Y. T. (2004) · Circulation · doi:10.1161/01.cir.0000125854.51637.06 · Cited by 321
Metadata
- Authors
- Liang, Q., Wendelhag, I., Wikstrand, J., & Gustavsson, T.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2000
- Volume
- 19
- Issue
- 2
- Pages
- 127-142
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2105282857
- Cited by
- 311
- References
- 27
- FWCI
- 12.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.