Improved analysis of brachial artery ultrasound using a novel edge-detection software system
Abstract
Brachial artery ultrasound is commonly employed for noninvasive assessment of endothelial function. However, analysis is observer dependent and susceptible to errors. We describe studies on a computerized edge-detection and wall-tracking software program to allow more accurate and reproducible measurement. In study 1, three purpose-built Perspex phantom arteries, 3.00, 4.00, and 6.00 mm in diameter, were measured with the software. There was a mean bias of 11 μm ( P < 0.001 at each level) between known and measured values; the mean resolving power of the software was estimated as 8.3 μm. In study 2, the mean intraobserver coefficient of variation of repeated measures of flow-mediated dilation (FMD) using the software (6.7%) was significantly lower than that for traditional manual measurements using the intima-lumen interfaces (24.8%, P < 0.05) and intima-media interfaces (32.5%, P < 0.05). In study 3, 24 healthy volunteers underwent repeat testing twice within 1 wk; the coefficients of variation for between-visit reproducibility of FMD and response to glyceryl trinitrate using the software were 14.7 and 17.6%, respectively. Assuming 80% power and an α of 0.05, eight subjects with matched controls would be required, in a parallel designed study, to detect an absolute 2.5% change in FMD. In summary, we have developed a semiautomated computerized vascular ultrasound analysis system that will improve the power of clinical intervention studies to detect small changes in arterial diameter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742
Close Relation of Endothelial Function in the Human Coronary and Peripheral Circulations
Anderson, T. J., Uehata, A., Gerhard, M. D., Meredith, I. T., Knab, S., Delagrange, D., Lieberman, E. H., Ganz, P., Creager, M. A., Yeung, A. C., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00327-4 · Cited by 2,033 · cited 1×
“Brachial arterial flow-mediated dilation (FMD), assessed by high-resolution ultrasound, reflects endothelium-dependent vasodilator function (4), which may be used as a surrogate for function of the coronary circulation (2).”
BackgroundMcVeigh, G. E., Brennan, G. M., Johnston, G. D., McDermott, B. J., McGrath, L. T., Henry, W. R., Andrews, J. W., & Hayes, J. R. (1992) · Diabetologia · doi:10.1007/bf00429099 · Cited by 916
Cited by
Effect of exercise training on endothelium‐derived nitric oxide function in humans
Green, D. J., Maiorana, A., O'Driscoll, G., & Taylor, R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.068197 · Cited by 1,040
Self-citationPyke, K. E., & Tschakovsky, M. E. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.089755 · Cited by 614
Shear Stress Mediates Endothelial Adaptations to Exercise Training in Humans
Tinken, T. M., Thijssen, D. H. J., Hopkins, N., Dawson, E. A., Cable, N. T., & Green, D. J. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.146282 · Cited by 493
Self-citationImportance of Measuring the Time Course of Flow-Mediated Dilatation in Humans
Black, M. A., Cable, N. T., Thijssen, D. H. J., & Green, D. J. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.101014 · Cited by 393
Self-citationRazvi, S., Ingoe, L., Keeka, G., Oates, C., McMillan, C., & Weaver, J. U. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2006-1869 · Cited by 389
Metadata
- Authors
- Woodman, R. J., Playford, D. A., Watts, G. F., Cheetham, C., Reed, C., Taylor, R. R., Puddey, I. B., Beilin, L. J., Burke, V., Mori, T. A., & Green, D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2001-08-01
- Volume
- 91
- Issue
- 2
- Pages
- 929-937
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2103474165
- Cited by
- 533
- References
- 3
- FWCI
- 6.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved analysis of brachial artery ultrasound using a novel edge-detection software system. https://app.cochat.ai/papers/10.1152/jappl.2001.91.2.929
- The paper
- Woodman, R. J., Playford, D. A., Watts, G. F., Cheetham, C., Reed, C., Taylor, R. R., Puddey, I. B., Beilin, L. J., Burke, V., Mori, T. A., & Green, D. (2001). Improved analysis of brachial artery ultrasound using a novel edge-detection software system. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2001.91.2.929
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.