The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Parametric estimate of intensity inhomogeneities applied to MRI
Abstract
This paper presents a new approach to the correction of intensity inhomogeneities in magnetic resonance imaging (MRI) that significantly improves intensity-based tissue segmentation. The distortion of the image brightness values by a low-frequency bias field impedes visual inspection and segmentation. The new correction method called parametric bias field correction (PABIC) is based on a simplified model of the imaging process, a parametric model of tissue class statistics, and a polynomial model of the inhomogeneity field. We assume that the image is composed of pixels assigned to a small number of categories with a priori known statistics. Further we assume that the image is corrupted by noise and a low-frequency inhomogeneity field. The estimation of the parametric bias field is formulated as a nonlinear energy minimization problem using an evolution strategy (ES). The resulting bias field is independent of the image region configurations and thus overcomes limitations of methods based on homomorphic filtering. Furthermore, PABIC can correct bias distortions much larger than the image contrast. Input parameters are the intensity statistics of the classes and the degree of the polynomial function. The polynomial approach combines bias correction with histogram adjustment, making it well suited for normalizing the intensity histogram of datasets from serial studies. We present simulations and a quantitative validation with phantom and test images. A large number of MR image data acquired with breast, surface, and head coils, both in two dimensions and three dimensions, have been processed and demonstrate the versatility and robustness of this new bias correction scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Modern heuristic techniques for combinatorial problems
Reeves, C. R. (1993) · Medical Entomology and Zoology · Cited by 2,580
Schwefel, H. (1995) · Cited by 2,203
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
MRI segmentation: Methods and applications
Clarke, L. P., Velthuizen, R. P., Camacho, M. A., Heine, J. J., Vaidyanathan, M., Hall, L. O., Thatcher, R. W., & Silbiger, M. L. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)00124-l · Cited by 695
Estimating the bias field of MR images
Guillemaud, R., & Brady, M. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585758 · Cited by 329
Segmentation of MR Brain Images into Cerebrospinal Fluid Spaces, White and Gray Matter
Lim, K. O., & Pfefferbaum, A. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198907000-00006 · Cited by 309
Cited by
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Marcus, D. S., Wang, T. H., Parker, J., Csernansky, J. G., Morris, J. C., & Buckner, R. L. (2007) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2007.19.9.1498 · Cited by 2,163
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
MP2RAGE, a self bias-field corrected sequence for improved segmentation and T1-mapping at high field
Marques, J. P., Kober, T., Krueger, G., van der Zwaag, W., Van de Moortele, P.-F., & Gruetter, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.002 · Cited by 1,453
Buckner, R. L., Head, D., Parker, J., Fotenos, A. F., Marcus, D., Morris, J. C., & Snyder, A. Z. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.018 · Cited by 1,296
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Multi-view self-supervised deep learning for 6D pose estimation in the Amazon Picking Challenge
Zeng, A., Yu, K.-T., Song, S., Suo, D., Walker, E., Rodriguez, A., & Xiao, J. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989165 · Cited by 457
Data Augmentation Using Learned Transformations for One-Shot Medical Image Segmentation
Zhao, A., Balakrishnan, G., Durand, F., Guttag, J. V., & Dalca, A. V. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.00874 · Cited by 430
A Level Set Approach to Image Segmentation With Intensity Inhomogeneity
Zhang, K., Zhang, L., Lam, K.-M., & Zhang, D. (2016) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2015.2409119 · Cited by 408
Li, C., Gore, J. C., & Davatzikos, C. (2014) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.03.010 · Cited by 371
Lemaître, G., Martí, R., Freixenet, J., Vilanova, J. C., Walker, P. M., & Meriaudeau, F. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.02.009 · Cited by 348
Automatic segmentation of MR images of the developing newborn brain
Prastawa, M., Gilmore, J. H., Lin, W., & Gerig, G. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.05.007 · Cited by 332
Self-citationCalderón-Garcidueñas, L., Engle, R., Mora-Tiscareño, A., Styner, M., Gómez-Garza, G., Zhu, H., Jewells, V., Torres-Jardón, R., Romero, L., Monroy-Acosta, M. E., et al. (2011) · Brain and Cognition · doi:10.1016/j.bandc.2011.09.006 · Cited by 323
Self-citationAn adaptive spatial fuzzy clustering algorithm for 3-D MR image segmentation
Liew, A. W.-C., & Yan, H. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.816956 · Cited by 316
BioImage Suite: An integrated medical image analysis suite: An update
Papademetris, X., Jackowski, M., Rajeevan, N., DiStasio, M., Okuda, H., Constable, R. T., & Staib, L. (2006) · The Insight Journal · doi:10.54294/2g80r4 · Cited by 298
Sheline, Y. I., Pieper, C. F., Barch, D. M., Welsh-Boehmer, K., McKinstry, R. C., MacFall, J. R., D’Angelo, G., Garcia, K. S., Gersing, K., Wilkins, C., et al. (2010) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2009.204 · Cited by 291
Sheline, Y. I., Price, J. L., Vaishnavi, S. N., Mintun, M. A., Barch, D. M., Epstein, A. A., Wilkins, C. H., Snyder, A. Z., Couture, L., Schechtman, K., et al. (2008) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2007.07010175 · Cited by 213
A review of Methods for Bias Correction in Medical Images
Song, S., Zheng, Y., & He, Y. (2017) · Biomedical Engineering Review · doi:10.18103/bme.v3i1.1550 · Cited by 62
Ventromedial prefrontal cortex thinning in preschool-onset depression
Marrus, N., Belden, A., Nishino, T., Handler, T., Ratnanather, J. T., Miller, M., Barch, D., Luby, J., & Botteron, K. (2015) · Journal of Affective Disorders · doi:10.1016/j.jad.2015.03.033 · Cited by 35
“A gain field correction using a 3D parabolic model of the gain field with 10 free parameters (Styner et al., 2000) was applied to minimize the effects of image inhomogeneity, and volume intensity was converted to 8-bits.”
Metadata
- Authors
- Styner, M., Brechbuhler, C., Szckely, G., & Gerig, G.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2000-03
- Volume
- 19
- Issue
- 3
- Pages
- 153-165
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2090056811
- Cited by
- 527
- References
- 21
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.