The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Gradient and texture analysis for the classification of mammographic masses
Abstract
Computer-aided classification of benign and malignant masses on mammograms is attempted in this study by computing gradient-based and texture-based features. Features computed based on gray-level co-occurrence matrices (GCMs) are used to evaluate the effectiveness of textural information possessed by mass regions in comparison with the textural information present in mass margins. A method involving polygonal modeling of boundaries is proposed for the extraction of a ribbon of pixels across mass margins. Two gradient-based features are developed to estimate the sharpness of mass boundaries in the ribbons of pixels extracted from their margins. A total of 54 images (28 benign and 26 malignant) containing 39 images from the Mammographic Image Analysis Society (MIAS) database and 15 images from a local database are analyzed. The best benign versus malignant classification of 82.1%, with an area (Az) of 0.85 under the receiver operating characteristics (ROC) curve, was obtained with the images from the MIAS database by using GCM-based texture features computed from mass margins. The classification method used is based on posterior probabilities computed from Mahalanobis distances. The corresponding accuracy using jack-knife classification was observed to be 74.4%, with Az = 0.67. Gradient-based features achieved Az = 0.6 on the MIAS database and Az = 0.76 on the combined database. The corresponding values obtained using jack-knife classification were observed to be 0.52 and 0.73 for the MIAS and combined databases, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical and structural approaches to texture
Haralick, R. M. (1979) · Proceedings of the IEEE · doi:10.1109/proc.1979.11328 · Cited by 5,759
Bhunia, C. T. (1997) · IETE Journal of Education · doi:10.1080/09747338.1997.11415666 · Cited by 2,701
BMPD statistical software manual
Dixon, W. (1988) · University of California Press eBooks · Cited by 2,536
Russ, J. C. (2006) · CRC Press eBooks · doi:10.1201/9780203881095 · Cited by 2,107
The Mammographic Image Analysis Society digital mammogram database
John Suckling, A., Parker, J., Astley, S., Hutt, I., Boggis, C. R. M., Ricketts, I. W., Stamatakis, E. A., Cerneaz, N., Kok, S., Taylor, P., et al. (1994) · Cited by 1,155
Measures of acutance and shape for classification of breast tumors
Rangayyan, R. M., El-Faramawy, N. M., Desautels, J. E. L., & Alim, O. A. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.650876 · Cited by 318
Self-citationAn approach to automated detection of tumors in mammograms
Brzakovic, D., Luo, X. M., & Brzakovic, P. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.57760 · Cited by 246
Chan, H.-P., Wei, D., Helvie, M. A., Sahiner, B., Adler, D. D., Goodsitt, M. M., & Petrick, N. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/5/010 · Cited by 208
Sahiner, B., Chan, H.-P., Petrick, N., Helvie, M. A., & Goodsitt, M. M. (1998) · Medical Physics · doi:10.1118/1.598228 · Cited by 205
Boundary modelling and shape analysis methods for classification of mammographic masses
Rangayyan, R. M., Mudigonda, N. R., & Desautels, J. E. L. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345742 · Cited by 198
Self-citation
Cited by
Large scale deep learning for computer aided detection of mammographic lesions
Kooi, T., Litjens, G., van Ginneken, B., Gubern-Mérida, A., Sánchez, C. I., Mann, R., den Heeten, A., & Karssemeijer, N. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.07.007 · Cited by 965
A curated mammography data set for use in computer-aided detection and diagnosis research
Lee, R. S., Gimenez, F., Hoogi, A., Miyake, K. K., Gorovoy, M., & Rubin, D. L. (2017) · Scientific Data · doi:10.1038/sdata.2017.177 · Cited by 859
Computer-Aided Detection and Diagnosis of Breast Cancer With Mammography: Recent Advances
Tang, J., Rangayyan, R. M., Xu, J., El Naqa, I., & Yang, Y. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.2009441 · Cited by 619
Self-citationApproaches for automated detection and classification of masses in mammograms
Cheng, H. D., Shi, X. J., Min, R., Hu, L. M., Cai, X. P., & Du, H. N. (2006) · Pattern Recognition · doi:10.1016/j.patcog.2005.07.006 · Cited by 538
Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.011 · Cited by 480
Metadata
- Authors
- Desautels, J. E. L., Rangayyan, R., & Mudigonda, N. R.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2000
- Volume
- 19
- Issue
- 10
- Pages
- 1032-1043
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2134916573
- Cited by
- 281
- References
- 17
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gradient and texture analysis for the classification of mammographic masses. https://app.cochat.ai/papers/10.1109/42.887618
- The paper
- Desautels, J. E. L., Rangayyan, R., & Mudigonda, N. R. (2000). Gradient and texture analysis for the classification of mammographic masses. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.887618
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.