Rapid 3-D cone-beam reconstruction with the simultaneous algebraic reconstruction technique (SART) using 2-D texture mapping hardware
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Algebraic reconstruction methods, such as the algebraic reconstruction technique (ART) and the related simultaneous ART (SART). reconstruct a two-dimensional (2-D) or three-dimensional (3-D) object from its X-ray projections. The algebraic methods have, in certain scenarios, many advantages over the more popular Filtered Backprojection approaches and have also recently been shown to perform well for 3-D cone-beam reconstruction. However, so far the slow speed of these iterative methods have prohibited their routine use in clinical applications. In this paper, we address this shortcoming and investigate the utility of widely available 2-D texture mapping graphics hardware for the purpose of accelerating the 3-D algebraic reconstruction. We find that this hardware allows 3-D cone-beam reconstructions to be obtained at almost interactive speeds, with speed-ups of over 50 with respect to implementations that only use general-purpose CPUs. However, we also find that the reconstruction quality is rather sensitive to the resolution of the framebuffer, and to address this critical issue we propose a scheme that extends the precision of a given framebuffer by 4 bits, using the color channels. With this extension, a 12-bit framebuffer delivers useful reconstructions for 0.5% tissue contrast, while an 8-bit framebuffer requires 4%. Since graphics hardware generates an entire image for each volume projection, it is most appropriately used with an algebraic reconstruction method that performs volume correction at that granularity as well, such as SART or SIRT. We chose SART for its faster convergence properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Cited by
Medical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
GPU computing in medical physics: A review
Pratx, G., & Xing, L. (2011) · Medical Physics · doi:10.1118/1.3578605 · Cited by 300
Accelerating popular tomographic reconstruction algorithms on commodity PC graphics hardware
Xu, F., & Mueller, K. (2005) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.851398 · Cited by 252
Self-citationAccelerating advanced MRI reconstructions on GPUs
Stone, S. S., Haldar, J. P., Tsao, S. C., Hwu, W.-M. W., Sutton, B. P., & Liang, Z.-P. (2008) · Journal of Parallel and Distributed Computing · doi:10.1016/j.jpdc.2008.05.013 · Cited by 249
3D Forward and Back-Projection for X-Ray CT Using Separable Footprints
Long, Y., Fessler, J. A., & Balter, J. M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2050898 · Cited by 228
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 223
Self-citationHigh-performance cone beam reconstruction using CUDA compatible GPUs
Okitsu, Y., Ino, F., & Hagihara, K. (2010) · Parallel Computing · doi:10.1016/j.parco.2010.01.004 · Cited by 70
“This texture-based idea is then extended by Mueller and Xu [23, 24] to implement various reconstruction methods on the GPU: the FDK algorithm [17]; ordered subsets expectation maximization (OSEM) [25]; and simultaneous algebraic reconstruction technique (SART) [26].”
MethodOn the efficiency of iterative ordered subset reconstruction algorithms for acceleration on GPUs
Xu, F., Xu, W., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.09.003 · Cited by 63
Self-citation
Metadata
- Authors
- Mueller, K., & Yagel, R.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2000
- Volume
- 19
- Issue
- 12
- Pages
- 1227-1237
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2140922423
- Cited by
- 129
- References
- 1
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.