The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In vivo measurement of 3-D skeletal kinematics from sequences of biplane radiographs: Application to knee kinematics
Abstract
Current noninvasive or minimally invasive methods for evaluating in vivo knee kinematics are inadequate for accurate determination of dynamic joint function due to limited accuracy and/or insufficient sampling rates. A three-dimensional (3-D) model-based method is presented to estimate skeletal motion of the knee from high-speed sequences of biplane radiographs. The method implicitly assumes that geometrical features cannot be detected reliably and an exact segmentation of bone edges is not always feasible. An existing biplane radiograph system was simulated as two separate single-plane radiograph systems. Position and orientation of the underlying bone was determined for each single-plane view by generating projections through a 3-D volumetric model (from computed tomography), and producing an image (digitally reconstructed radiograph) similar (based on texture information and rough edges of bone) to the two-dimensional radiographs. The absolute 3-D pose was determined using known imaging geometry of the biplane radiograph system and a 3-D line intersection method. Results were compared to data of known accuracy, obtained from a previously established bone-implanted marker method. Difference of controlled in vitro tests was on the order of 0.5 mm for translation and 1.4 degrees for rotation. A biplane radiograph sequence of a canine hindlimb during treadmill walking was used for in vivo testing, with differences on the order of 0.8 mm for translation and 2.5 degrees for rotation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Cited by
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
Brainerd, E. L., Baier, D. B., Gatesy, S. M., Hedrick, T. L., Metzger, K. A., Gilbert, S. L., & Crisco, J. J. (2010) · Journal of Experimental Zoology Part A: Ecological Genetics and Physiology · doi:10.1002/jez.589 · Cited by 524
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Bey, M. J., Zauel, R., Brock, S. K., & Tashman, S. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2206199 · Cited by 300
Self-citation
Metadata
- Authors
- You, B.-M., Siy, P., Anderst, W., & Tashman, S.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001-06
- Volume
- 20
- Issue
- 6
- Pages
- 514-525
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2169734502
- Cited by
- 200
- References
- 1
- FWCI
- 5.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.