The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Automated segmentation of multiple sclerosis lesions by model outlier detection
Abstract
This paper presents a fully automated algorithm for segmentation of multiple sclerosis (MS) lesions from multispectral magnetic resonance (MR) images. The method performs intensity-based tissue classification using a stochastic model for normal brain images and simultaneously detects MS lesions as outliers that are not well explained by the model. It corrects for MR field inhomogeneities, estimates tissue-specific intensity models from the data itself, and incorporates contextual information in the classification using a Markov random field. The results of the automated method are compared with lesion delineations by human experts, showing a high total lesion load correlation. When the degree of spatial correspondence between segmentations is taken into account, considerable disagreement is found, both between expert segmentations, and between expert and automatic measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Rating neurologic impairment in multiple sclerosis: An expanded disability status scale (EDSS)
Kurtzke, J. F. (1983) · Neurology · doi:10.1212/wnl.33.11.1444 · Cited by 15,011
Measures of the Amount of Ecologic Association Between Species
Dice, L. R. (1945) · Ecology · doi:10.2307/1932409 · Cited by 11,874
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
Self-citationMaximum likelihood estimation from incomplete data via the EM algorithm
Dempster, A. P. (1977) · Journal of the Royal Statistical Society Series A (Statistics in Society) · Cited by 4,543
Beitrag zur Theorie des Ferromagnetismus
Ising, E. (1925) · Zeitschrift für Physik · doi:10.1007/bf02980577 · Cited by 3,871
Wiley Series in Probability and Mathematics Statistics
(1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250.scard · Cited by 2,220
Paty, D. W., Li, D. K. B., the UBC MS/MRI Study Group, & the IFNB Multiple Sclerosis Study Group (1993) · Neurology · doi:10.1212/wnl.43.4.662 · Cited by 1,967
3D statistical neuroanatomical models from 305 MRI volumes
Evans, A. C., Collins, D. L., Mills, S. R., Brown, E. D., Kelly, R. L., & Peters, T. M. (2005) · 1993 IEEE Conference Record Nuclear Science Symposium and Medical Imaging Conference · doi:10.1109/nssmic.1993.373602 · Cited by 1,487
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Morphometric analysis of white matter lesions in MR images: method and validation
Zijdenbos, A. P., Dawant, B. M., Margolin, R. A., & Palmer, A. C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363096 · Cited by 1,265
Automated model-based tissue classification of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811270 · Cited by 1,024
Self-citationRobust clustering methods: a unified view
Dave, R. N., & Krishnapuram, R. (1997) · IEEE Transactions on Fuzzy Systems · doi:10.1109/91.580801 · Cited by 711
Statistical Parametric Mapping
Friston, K. J. (2003) · Neuroscience Databases · doi:10.1007/978-1-4615-1079-6_16 · Cited by 678
Automated model-based bias field correction of MR images of the brain
Van Leemput, K., Maes, F., Vandermeulen, D., & Suetens, P. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811268 · Cited by 583
Self-citationStatistical Parametric Mapping
(2007) · Elsevier eBooks · doi:10.1016/b978-0-12-372560-8.x5000-1 · Cited by 387
Estimating the bias field of MR images
Guillemaud, R., & Brady, M. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.585758 · Cited by 329
Multiple sclerosis lesion quantification using fuzzy-connectedness principles
Udupa, J. K., Wei, L., Samarasekera, S., Miki, Y., van Buchem, M. A., & Grossman, R. I. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.640750 · Cited by 314
Segmentation of multiple sclerosis lesions in intensity corrected multispectral MRI
Johnston, B., Atkins, M. S., Mackiewich, B., & Anderson, M. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491417 · Cited by 260
Multi-modality image registration by maximization of mutual information
Maes, F., Vandermeulen, D., & Suetens, P. L. (2000) · Cited by 255
Self-citationUnderstanding Robust and Exploratory Data Analysis.
Healy, M. J. R., Hoaglin, D. C., Mosteller, F., & Tukey, J. W. (1983) · Biometrics · doi:10.2307/2531362 · Cited by 230
Model-based 3-D segmentation of multiple sclerosis lesions in magnetic resonance brain images
Kamber, M., Shinghal, R., Collins, D. L., Francis, G. S., & Evans, A. C. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414608 · Cited by 211
Non-rigid matching using demons
Thirion, J.-P. (1996) · Proceedings CVPR IEEE Computer Society Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1996.517081 · Cited by 197
Gaussian mixture density modeling, decomposition, and applications
Zhuang, X., Huang, Y., Palaniappan, K., & Zhao, Y. (1996) · IEEE Transactions on Image Processing · doi:10.1109/83.535841 · Cited by 187
Quantitative assessment of MRI lesion load in monitoring the evolution of multiple sclerosis
Filippi, M., Horsfield, M. A., Tofts, P. S., Barkhof, F., Thompson, A. J., & Miller, D. H. (1995) · Brain · doi:10.1093/brain/118.6.1601 · Cited by 178
An adaptive segmentation algorithm for time-of-flight MRA data
Wilson, D. L., & Noble, J. A. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.811277 · Cited by 174
Warfield, S. K., Dengler, J., Zaers, J., Guttmann, C. R. G., Wells, W. M., Ettinger, G. J., Hiller, J. B., & Kikinis, R. (1995) · Journal of Image Guided Surgery · Cited by 172
Automatic quantification of MS lesions in 3D MRI brain data sets: Validation of INSECT
Zijdenbos, A., Forghani, R., & Evans, A. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056229 · Cited by 168
Robust cluster analysis via mixtures of multivariate t-distributions
McLachlan, G. J., & Peel, D. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0033290 · Cited by 160
Paty, D. W., & Li, D. K. (2001) · PubMed · Cited by 130
Thirion, J.-P., & Calmon, G. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.774170 · Cited by 123
Automatic quantification of multiple sclerosis lesion volume using stereotaxic space
Zijdenbos, A. P., Evans, A. C., Riahi, F., Sled, J. G., Chui, J., & Kollokian, V. (1996) · Lecture notes in computer science · doi:10.1007/bfb0046984 · Cited by 113
Robust parameter estimation of intensity distributions for brain magnetic resonance images
Schroeter, P., Vésin, J.-M., Langenberger, T., & Meuli, R. A. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700730 · Cited by 108
The Role of MRI in clinical trials of multiple sclerosis: Comparison of image processing techniques
Evans, A. C., Frank, J. A., Antel, J. P., & Miller, D. H. (1997) · Annals of Neurology · doi:10.1002/ana.410410123 · Cited by 91
Statistical 3D Vessel Segmentation Using a Rician Distribution
Chung, A. C. S., & Noble, J. A. (1999) · Lecture notes in computer science · doi:10.1007/10704282_9 · Cited by 73
Gerig, G., Welti, D., Guttmann, C. R. G., Colchester, A. C. F., & Székely, G. J. (2000) · Medical Image Analysis · doi:10.1016/s1361-8415(00)00005-0 · Cited by 64
Self-citationRey, D., Subsol, G., Delingette, H., & Ayache, N. (1999) · Lecture notes in computer science · doi:10.1007/3-540-48714-x_12 · Cited by 35
Measuring global and local spatial correspondence using information theory
Bello, F., & Colchester, A. C. F. (1998) · Lecture notes in computer science · doi:10.1007/bfb0056285 · Cited by 27
Self-citationWansapura (1999) · doi:10.1002/(sici)1522-2586(199904)9:4
Cited by
The multimodal brain tumor image segmentation benchmark (BRATS)
Menze, B. H., Jakab, A., Bauer, S., Kalpathy-Cramer, J., Farahani, K., Kirby, J., Burren, Y., Porz, N., Slotboom, J., Wiest, R., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2377694 · Cited by 6,781
Self-citationAn automated tool for detection of FLAIR-hyperintense white-matter lesions in Multiple Sclerosis
Schmidt, P., Gaser, C., Arsic, M., Buck, D., Förschler, A., Berthele, A., Hoshi, M., Ilg, R., Schmid, V. J., Zimmer, C., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.032 · Cited by 1,223
A Review of Methods for Correction of Intensity Inhomogeneity in MRI
Vovk, U., Pernus, F., & Likar, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.891486 · Cited by 851
Automatic "pipeline" analysis of 3-D MRI data for clinical trials: application to multiple sclerosis
Zijdenbos, A. P., Forghani, R., & Evans, A. C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806283 · Cited by 761
Evans, A. C., Janke, A. L., Collins, D. L., & Baillet, S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.024 · Cited by 695
Metadata
- Authors
- Van Leemput, K., Maes, F., Vandermeulen, D., Colchester, A., & Suetens, P.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001
- Volume
- 20
- Issue
- 8
- Pages
- 677-688
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2168399612
- Cited by
- 489
- References
- 40
- FWCI
- 15.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.