The DOI matches its Crossref record.
Voxel-based 2-D/3-D registration of fluoroscopy images and CT scans for image-guided surgery
Abstract
Registration of intraoperative fluoroscopy images with preoperative three-dimensional (3-D) CT images can be used for several purposes in image-guided surgery. On the one hand, it can be used to display the position of surgical instruments, which are being tracked by a localizer, in the preoperative CT scan. On the other hand, the registration result can be used to project preoperative planning information or important anatomical structures visible in the CT image onto the fluoroscopy image. For this registration task, a novel voxel-based method in combination with a new similarity measure (pattern intensity) has been developed. The basic concept of the method is explained at the example of two-dimensional (2-D)/3-D registration of a vertebra in an X-ray fluoroscopy image with a 3-D CT image. The registration method is described, and the results for a spine phantom are presented and discussed. Registration has been carried out repeatedly with different starting estimates to study the capture range. Information about registration accuracy has been obtained by comparing the registration results with a highly accurate "ground-truth" registration, which has been derived from fiducial markers attached to the phantom prior to imaging. In addition, registration results for different vertebrae have been compared. The results show that the rotation parameters and the shifts parallel to the projection plane can accurately be determined from a single projection. Because of the projection geometry, the accuracy of the height above the projection plane is significantly lower.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Self-citationHAMMER: hierarchical attribute matching mechanism for elastic registration
Shen, D., & Davatzikos, C. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.803111 · Cited by 1,083
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Fast parametric elastic image registration
Kybic, J., & Unser, M. (2003) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.813139 · Cited by 477
Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820027 · Cited by 305
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Image Similarity Using Mutual Information of Regions
Russakoff, D. B., Tomasi, C., Rohlfing, T., & Maurer, C. R. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24672-5_47 · Cited by 286
Voxel similarity measures for 3-D serial MR brain image registration
Holden, M., Hill, D. L. G., Denton, E. R. E., Jarosz, J. M., Cox, T. C. S., Rohlfing, T., Goodey, J., & Hawkes, D. J. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.836369 · Cited by 277
Self-citationVision-based and marker-less surgical tool detection and tracking: a review of the literature
Bouget, D., Allan, M., Stoyanov, D., & Jannin, P. (2017) · Medical Image Analysis · doi:10.1016/j.media.2016.09.003 · Cited by 277
Russakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
van der Bom, I. M. J., Klein, S., Staring, M., Homan, R., Bartels, L. W., & Pluim, J. P. W. (2011) · SPIE Proceedings · doi:10.1117/12.877655 · Cited by 55
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
Fully automated 2D–3D registration and verification
Varnavas, A., Carrell, T., & Penney, G. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.08.005 · Cited by 50
Self-citation2d/3d Registration of Endoscopic Ultrasound to Ct Volume Data
Hummel, J., Figl, M., Bax, M., Bergmann, H., & Birkfellner, W. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/16/006 · Cited by 47
Evaluation of Intensity-Based 2D-3D Spine Image Registration Using Clinical Gold-Standard Data
Russakoff, D. B., Rohlfing, T., Ho, A., Kim, D. H., Shahidi, R., Adler, J. R., & Maurer, C. R. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39701-4_16 · Cited by 43
Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
van der Bom, M. J., Pluim, J. P. W., Gounis, M. J., van de Kraats, E. B., Sprinkhuizen, S. M., Timmer, J., Homan, R., & Bartels, L. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/010 · Cited by 21
“Gold Standard” 2D/3D Registration of X-Ray to CT and MR Images
Tomaevič, D., Likar, B., & Pernuš, F. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45787-9_58 · Cited by 9
Metadata
- Authors
- Weese, J., Penney, G. P., Desmedt, P., Buzug, T. M., Hill, D. L. G., & Hawkes, D. J.
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 1997
- Volume
- 1
- Issue
- 4
- Pages
- 284-293
- ISSN
- 1089-7771 (ISSN-L)
- OpenAlex
- W2110726915
- Cited by
- 164
- References
- 0
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.