The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Micromachined inertial sensors
Abstract
This paper presents a review of silicon micromachined accelerometers and gyroscopes. Following a brief introduction to their operating principles and specifications, various device structures, fabrication, technologies, device designs, packaging, and interface electronics issues, along with the present status in the commercialization of micromachined inertial sensors, are discussed. Inertial sensors have seen a steady improvement in their performance, and today, microaccelerometers can resolve accelerations in the micro-g range, while the performance of gyroscopes has improved by a factor of 10/spl times/ every two years during the past eight years. This impressive drive to higher performance, lower cost, greater functionality, higher levels of integration, and higher volume will continue as new fabrication, circuit, and packaging techniques are developed to meet the ever increasing demand for inertial sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A batch-fabricated silicon accelerometer
Roylance, L. M., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19795 · Cited by 512
Binnig, G., & Rohrer, H. (2000) · IBM Journal of Research and Development · doi:10.1147/rd.441.0279 · Cited by 337
A MICROMACHINED VIBRATING RING GYROSCOPE
Putty, M. W., & Najafi, K. (1994) · 1994 Solid-State, Actuators, and Microsystems Workshop Technical Digest · doi:10.31438/trf.hh1994.49 · Cited by 316
Self-citationSqueeze-film damping in solid-state accelerometers
Starr, J. B. (1990) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.1109/solsen.1990.109817 · Cited by 306
Surface micromachined accelerometers
Boser, B. E., & Howe, R. T. (1996) · IEEE Journal of Solid-State Circuits · doi:10.1109/4.494198 · Cited by 286
Modern Inertial Technology: Navigation, Guidance, and Control
Lawrence, A. W. (1993) · Cited by 207
Surface Micromachined Z-Axis Vibratory Rate Gyroscope
Clark, W. A., Horowitz, R., & Howe, R. T. (1996) · 1996 Solid-State, Actuators, and Microsystems Workshop Technical Digest · doi:10.31438/trf.hh1996.64 · Cited by 206
An Integrated Force-balanced Capacitive Accelerometer For Low-G Applications
Chau, K. H.-L., Lewis, S. R., Zhao, Y., Howe, R. T., Bart, S. F., & Marcheselli, R. G. (2005) · Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95 · doi:10.1109/sensor.1995.717294 · Cited by 189
Söderkvist, J. (1994) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(93)00667-s · Cited by 189
Lawrence, A. W. (1993) · Springer eBooks · doi:10.1007/978-1-4684-0444-9 · Cited by 128
Analysis of a highly sensitive silicon gyroscope with cantilever beam as vibrating mass
Maenaka, K., Fujita, T., Konishi, Y., & Maeda, M. (1996) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)80016-7 · Cited by 96
Design and fabrication of high-performance polysilicon vibrating ring gyroscope
Ayazi, F., & Najafi, K. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1998.659829 · Cited by 76
Self-citationElectronics for micromachined inertial sensors
Boser, B. E. (2002) · doi:10.1109/sensor.1997.635413 · Cited by 71
Micromachined Dual Input Axis Angular Rate Sensor
Juneau, T. N., & Pisano, A. P. (1996) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh1996.67 · Cited by 47
A smart accelerometer with on-chip electronics fabricated by a commercial CMOS process
Riethmüller, W., Benecke, W., Schnakenberg, U., & Wagner, B. (1992) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(92)80090-p · Cited by 43
Analysis, design, and performance of micropower circuits for a capacitive pressure sensor IC
Smith, M. J. S., Bowman, L., & MEINDL, J. D. (1986) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1986.1052647 · Cited by 34
Silicon bulk micromachined vibratory gyroscope for microspacecraft
Tang, T. K., Gutierrez, R. C., Wilcox, J. Z., Stell, C., Vorpérian, V., Dickerson, M., Goldstein, B., Savino, J. L., Li, W. J., Calvet, R. J., et al. (1996) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.255129 · Cited by 31
Cited by
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Review: Semiconductor Piezoresistance for Microsystems
Barlian, A. A., Park, W.-T., Mallon, J. R., Rastegar, A. J., & Pruitt, B. L. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2013612 · Cited by 949
Microelectromechanical systems (MEMS): fabrication, design and applications
Judy, J. W. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/6/301 · Cited by 828
Machine Learning Methods for Classifying Human Physical Activity from On-Body Accelerometers
Mannini, A., & Sabatini, A. M. (2010) · Sensors · doi:10.3390/s100201154 · Cited by 781
An Introduction to Microelectromechanical Systems Engineering
Maluf, N. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/2/701 · Cited by 694
Metadata
- Authors
- Yazdi, N., Ayazi, F., & Najafi, K.
- Venue
- Proceedings of the IEEE
- Published
- 1998
- Volume
- 86
- Issue
- 8
- Pages
- 1640-1659
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2149128480
- Cited by
- 1,823
- References
- 17
- FWCI
- 29.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.