The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Scanning tunneling microscopy
Abstract
Presented here is an overview of the present status and future prospects of scanning tunneling microscopy. Topics covered include the physical basis of the scanning tunneling microscope, its instrumentation aspects, and its use for structural and spectroscopic imaging—on a scale which extends to atomic dimensions. Associated experimental and theoretical studies are reviewed, including several which suggest potential applicability of this new type of microscope to a relatively broad range of biological, chemical, and technological areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Self-citationElectron emission in intense electric fields
Fowler, R. H., & Nordheim, L. (1928) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1928.0091 · Cited by 5,752
Surface Studies by Scanning Tunneling Microscopy
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Physical Review Letters · doi:10.1103/physrevlett.49.57 · Cited by 4,777
Self-citationTheory of the scanning tunneling microscope
Tersoff, J., & Hamann, D. R. (1985) · Physical Review B · doi:10.1103/physrevb.31.805 · Cited by 4,411
Simmons, J. G. (1963) · Journal of Applied Physics · doi:10.1063/1.1702682 · Cited by 4,200
Theory and Application for the Scanning Tunneling Microscope
Tersoff, J., & Hamann, D. R. (1983) · Physical Review Letters · doi:10.1103/physrevlett.50.1998 · Cited by 2,554
Optical stethoscopy: Image recording with resolution λ/20
Pohl, D. W., Denk, W., & Lanz, M. (1984) · Applied Physics Letters · doi:10.1063/1.94865 · Cited by 2,040
Tunnelling from a Many-Particle Point of View
Bardeen, J. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.57 · Cited by 1,962
7 × 7 Reconstruction on Si(111) Resolved in Real Space
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1983) · Physical Review Letters · doi:10.1103/physrevlett.50.120 · Cited by 1,930
Self-citationTunneling through a controllable vacuum gap
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Applied Physics Letters · doi:10.1063/1.92999 · Cited by 1,841
Self-citation
Cited by
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Biomaterials and emerging anticancer therapeutics: engineering the microenvironment
Gu, L., & Mooney, D. J. (2016) · Nature Reviews Cancer · doi:10.1038/nrc.2015.3 · Cited by 407
Organic structure determination using atomic-resolution scanning probe microscopy
Gross, L., Mohn, F., Moll, N., Meyer, G., Ebel, R., Abdel-Mageed, W. M., & Jaspars, M. (2010) · Nature Chemistry · doi:10.1038/nchem.765 · Cited by 340
Metadata
- Authors
- Binnig, G., & Rohrer, H.
- Venue
- IBM Journal of Research and Development
- Publisher
- IBM
- Published
- 2000-01
- Volume
- 44
- Issue
- 1.2
- Pages
- 279-293
- ISSN
- 0018-8646 (ISSN-L)
- OpenAlex
- W2055759100
- Cited by
- 337
- References
- 34
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Scanning tunneling microscopy. https://app.cochat.ai/papers/10.1147/rd.441.0279
- The paper
- Binnig, G., & Rohrer, H. (2000). Scanning tunneling microscopy. IBM Journal of Research and Development. https://doi.org/10.1147/rd.441.0279
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.