The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Micromachined thermally based CMOS microsensors
Abstract
An integrated circuit (IC) approach to thermal microsensors is presented. The focus is on thermal sensors with on-chip bias and signal conditioning circuits made by industrial complementary metal-oxide-semiconductor (CMOS) IC technology in combination with post-CMOS micromachining or deposition techniques. CMOS materials and physical effects pertinent to thermal sensors are summarized together with basic structures used for microheaters, thermistors, thermocouples, thermal isolation, and heat sinks. As examples of sensors using temperature measurement, we present micromachined CMOS radiation sensors and thermal converters. Examples for sensors based on thermal actuation include thermal flow and pressure sensors, as well as thermally excited microresonators for position and chemical sensing. We also address sensors for the characterization of process-dependent thermal properties of CMOS materials, such as thermal conductivity, Seebeck coefficient, and heat capacity, whose knowledge is indispensable for thermal sensor design. Last, two complete packaged microsystems-a thermoelectric air-flow sensor and a thermoelectric infrared intrusion detector-are reported as demonstrators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconductor Material and Device Characterization
Schroder, D. K. (2005) · Wiley eBooks · doi:10.1002/0471749095 · Cited by 7,435
Thermophysical Properties of Matter
Touloukian, Y. S. (1995) · CERN Document Server (European Organization for Nuclear Research) · Cited by 3,282
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Bulk micromachining of silicon
Kovacs, G. T. A., Maluf, N. I., & Petersen, K. E. (1998) · Proceedings of the IEEE · doi:10.1109/5.704259 · Cited by 733
Surface micromachining for microelectromechanical systems
Bustillo, J. M., Howe, R. T., & Muller, R. S. (1998) · Proceedings of the IEEE · doi:10.1109/5.704260 · Cited by 644
Thermal sensors based on the seebeck effect
Van Herwaarden, A. W., & Sarro, P. M. (1986) · Sensors and Actuators · doi:10.1016/0250-6874(86)80053-1 · Cited by 464
Johnson, R. G., & Higashi, R. E. (1987) · Sensors and Actuators · doi:10.1016/0250-6874(87)85005-9 · Cited by 141
Processing and characterization of a model functionally gradient material
Parameswaran, V., & Shukla, A. (2000) · Journal of Materials Science · doi:10.1023/a:1004767910762 · Cited by 139
An integrated mass flow sensor with on-chip CMOS interface circuitry
Yoon, E., & Wise, K. D. (1992) · IEEE Transactions on Electron Devices · doi:10.1109/16.137317 · Cited by 136
A Microstructure For Measurement Of Thermal Conductivity Of Polysilicon Thin Films
Völklein, F., & Balles, H. (1992) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.1992.752511 · Cited by 98
Silicon gas flow sensors using industrial CMOS and bipolar IC technology
Moser, D., Lenggenhager, R., & Baltes, H. (1991) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(91)87054-7 · Cited by 98
Self-citationDetermination of the thermal conductivity of CMOS IC polysilicon
Paul, O., Korvink, J. G., & Baltes, H. (1994) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(94)80106-1 · Cited by 57
Self-citationProcess-dependent Thermophysical Properties Of CMOS IC Thin Films
Paul, O., von Arx, M., & Baltes, H. (2005) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1995.717128 · Cited by 53
Self-citationCMOS integration of a thermal pressure sensor system
Hàberli, A., Paul, O., Malcovati, P., et al. (2002) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.1996.539908 · Cited by 36
Self-citationA wideband monolithic RMS-DC converter using micromachined diaphragm structures
Yoon, E., & Wise, K. D. (1994) · IEEE Transactions on Electron Devices · doi:10.1109/16.310122 · Cited by 30
Determination of the heat capacity of CMOS layers for optimal CMOS sensor design
von Arx, M., Paul, O., & Baltes, H. (1995) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(94)00935-b · Cited by 26
Self-citationA Bulk-micromachined 1024-element Uncooled Infrared Imager
Oliver, A. D., Baer, W. G., & Wise, K. D. (2005) · Proceedings of the International Solid-State Sensors and Actuators Conference - TRANSDUCERS '95 · doi:10.1109/sensor.1995.721912 · Cited by 25
Sacrificial aluminum etching for CMOS microstructures
Paul, O., Westberg, D., Hornung, M. R., et al. (2002) · doi:10.1109/memsys.1997.581918 · Cited by 19
Self-citation
Cited by
Ziaie, B. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.09.001 · Cited by 456
Lange, D., Hagleitner, C., Hierlemann, A., Brand, O., & Baltes, H. (2002) · Analytical Chemistry · doi:10.1021/ac011269j · Cited by 307
Self-citationMicrosensor Integration Into Systems-on-Chip
Brand, O. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.873618 · Cited by 106
Self-citationMembrane-based thermal flow sensors on flexible substrates
Sturm, H., & Lang, W. (2013) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2013.03.004 · Cited by 37
Metadata
- Authors
- Baltes, H., Paul, O., & Brand, O.
- Venue
- Proceedings of the IEEE
- Published
- 1998
- Volume
- 86
- Issue
- 8
- Pages
- 1660-1678
- ISSN
- 0018-9219 (ISSN-L)
- OpenAlex
- W2171849451
- Cited by
- 261
- References
- 18
- FWCI
- 16.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.