The DOI matches its Crossref record.
Comparing wavelet transforms for recognizing cardiac patterns
Open accessAbstract
The authors' study made use of wavelet transforms to describe and recognize isolated cardiac beats. The choice of the wavelet family as well as the selection of the analyzing function into these families are discussed. The criterion used in the first case was the correct classification rate, and in the second case, the correlation coefficient between the original pattern and the reconstructed one. Two types of description have been considered-the energy-based representation and the extrema distribution estimated at each decomposition level-and their quality has been assessed by using principal component analysis. Their capability of discrimination between normal, premature ventricular contraction, and ischemic beats has been studied by means of linear discriminant analysis. This work leads also, for the problem at hand, to the identification of the most relevant resolution levels.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Automatic Classification of Heartbeats Using ECG Morphology and Heartbeat Interval Features
deChazal, P., O'Dwyer, M., & Reilly, R. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827359 · Cited by 1,671
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
“Senhadji et al (1995) compared the ability of three different wavelets transforms (Daubechies, spline and Morlet) to recognize and describe isolated cardiac beats.”
BackgroundA review of wavelets in biomedical applications
Unser, M., & Aldroubi, A. (1996) · Proceedings of the IEEE · doi:10.1109/5.488704 · Cited by 754
A Patient-Adapting Heartbeat Classifier Using ECG Morphology and Heartbeat Interval Features
de Chazal, P., & Reilly, R. B. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883802 · Cited by 497
Real-time discrimination of ventricular tachyarrhythmia with Fourier-transform neural network
Minami, K., Nakajima, H., & Toyoshima, T. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740880 · Cited by 465
Wavelet and wavelet packet compression of electrocardiograms
Hilton, M. L. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.568915 · Cited by 415
Inan, O. T., Giovangrandi, L., & Kovacs, G. T. A. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880879 · Cited by 402
Optimization of ECG Classification by Means of Feature Selection
Mar, T., Zaunseder, S., Martínez, J. P., Llamedo, M., & Poll, R. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2113395 · Cited by 324
A novel application of deep learning for single-lead ECG classification
Mathews, S. M., Kambhamettu, C., & Barner, K. E. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.013 · Cited by 322
Abnormal ECG signal detection based on compressed sampling in Wearable ECG sensor
Ding, H., Sun, H., & Hou, K.-M. (2011) · 2011 International Conference on Wireless Communications and Signal Processing (WCSP) · doi:10.1109/wcsp.2011.6096677 · Cited by 16
“This wearable, miniaturized and wireless sensor is able to monitor ECG signals and wireless report cardiac signals to a coordinator, which is responsible to transmit them to a local and remote surveillance server for tele-health [1,2].”
Background
Metadata
- Authors
- Senhadji, L., Carrault, G., Bellanger, J. J., & Passariello, G.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 1995
- Volume
- 14
- Issue
- 2
- Pages
- 167-173
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W1998322473
- Cited by
- 211
- References
- 0
- FWCI
- 3.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.