Micromachined needle arrays for drug delivery or fluid extraction
The DOI matches its Crossref record.
Abstract
Micromachined needle arrays have been designed, fabricated, and characterized. The design includes arrays of 25 needles with fluid coupling channels and dual structural supports. Numerical modeling of fluid flow characteristics was performed, demonstrating that the needle coupling channels redistribute flow when the input or output ports are fully restricted. Micromachining technologies have been used to batch fabricate hollow metallic fluid coupled needle arrays. The significance of this work includes the development of the hollow metallic micromachined needle arrays for biomedical applications, as well as a discussion of structural, fluidic, and biological design considerations. The micromachined needle array has many advantages, including (a) reduced trauma at penetration site (small size), (b) greater freedom of patient movement (minimal penetration), (c) a practically pain-free drug delivery device (distribution of force), (d) precise control of penetration depth (needle extension length), and (e) they can be stacked and packaged into a 3-D device for fluid transfer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microneedles for drug and vaccine delivery
Kim, Y.-C., Park, J.-H., & Prausnitz, M. R. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.04.005 · Cited by 1,760
Davis, S. P., Landis, B. J., Adams, Z. H., Allen, M. G., & Prausnitz, M. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.010 · Cited by 934
McAllister, D. V., Wang, P. M., Davis, S. P., Park, J.-H., Canatella, P. J., Allen, M. G., & Prausnitz, M. R. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331316100 · Cited by 859
Current challenges in non-invasive insulin delivery systems: A comparative review
Khafagy, E.-S., Morishita, M., Onuki, Y., & Takayama, K. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.019 · Cited by 436
Silicon micromachined hollow microneedles for transdermal liquid transport
Gardeniers, H. J. G. E., Luttge, R., Berenschot, E. J. W., de Boer, M. J., Yeshurun, S. Y., Hefetz, M., van-t Oever, R., & van den Berg, A. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820293 · Cited by 413
“[7], [8], and the surface micromachined polysilicon microneedles with permeable polysilicon on one side which serves as a microdialysis membrane [9], [10].”
Background
Metadata
- Authors
- Brazzle, J., Papautsky, I., & Frazier, A. B.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 1999
- Volume
- 18
- Issue
- 6
- Pages
- 53-58
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2044233978
- Cited by
- 56
- References
- 0
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Micromachined needle arrays for drug delivery or fluid extraction. https://app.cochat.ai/papers/10.1109/51.805145
- The paper
- Brazzle, J., Papautsky, I., & Frazier, A. B. (1999). Micromachined needle arrays for drug delivery or fluid extraction. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/51.805145
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.