A wireless near-infrared energy system for medical implants
The DOI matches its Crossref record.
Abstract
A less invasive method for supplying light power to implant devices, we propose a new wireless energy source that employs a near-infrared laser with a photovoltaic cell. The system can also be used with a rechargeable battery. We discuss the configuration of the system, show its energy transfer efficiency, and discuss its performance during some basic experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
Challenges for successful implantation of biofuel cells
Zebda, A., Alcaraz, J.-P., Vadgama, P., Shleev, S., Minteer, S. D., Boucher, F., Cinquin, P., & Martin, D. K. (2018) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2018.05.011 · Cited by 224
An implantable power supply with an optically rechargeable lithium battery
Goto, K., Nakagawa, T., Nakamura, O., & Kawata, S. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930908 · Cited by 159
“In this paper, we report a modified version of the near-infrared power supply discussed in [4].”
BackgroundSelf-citationWireless communication with implanted medical devices using the conductive properties of the body
Ferguson, J. E., & Redish, A. D. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.16 · Cited by 112
Review on medical implantable antenna technology and imminent research challenges
Soliman, M. M., Chowdhury, M. E. H., Khandakar, A., Islam, M. T., Qiblawey, Y., Musharavati, F., & Zal Nezhad, E. (2021) · Sensors · doi:10.3390/s21093163 · Cited by 95
High-performance wireless powering for peripheral nerve neuromodulation systems
Tanabe, Y., Ho, J. S., Liu, J., Liao, S.-Y., Zhen, Z., Hsu, S., Shuto, C., Zhu, Z.-Y., Ma, A., Vassos, C., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186698 · Cited by 63
Metadata
- Authors
- Murakawa, K., Kobayashi, M., Nakamura, O., & Kawata, S.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 1999
- Volume
- 18
- Issue
- 6
- Pages
- 70-72
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2083058167
- Cited by
- 87
- References
- 0
- FWCI
- 1.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.