The subcutaneous route to insulin dependent diabetes therapy
The DOI matches its Crossref record.
Abstract
Discusses closed-loop and partially closed-loop control strategies for insulin delivery and measuring glucose concentration. The authors review the subcutaneous closed- and partially closed-loop strategies that have been proposed and tested in recent years for insulin-dependent diabetes therapy. Focus is on control, modeling, and information technology aspects, and future directions of research are also outlined. This survey complements earlier reviews concerning control approaches and application of computers in diabetes care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes
Kovatchev, B. P., Breton, M., Dalla Man, C., & Cobelli, C. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300106 · Cited by 760
Self-citationArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Self-citationMakroglou, A., Li, J., & Kuang, Y. (2006) · Applied Numerical Mathematics · doi:10.1016/j.apnum.2005.04.023 · Cited by 367
“See Parker et al. (2001) [54] and Bellazzi et al. (2001) [6] for two more review papers for intravenous and subcutaneous insulin kinetics respectively.”
BackgroundAn Improved PID Switching Control Strategy for Type 1 Diabetes
Marchetti, G., Barolo, M., Jovanovic, L., Zisser, H., & Seborg, D. E. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.915665 · Cited by 212
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200
Self-citationModel-based blood glucose control for type 1 diabetes via parametric programming
Dua, P., Doyle, F. J., & Pistikopoulos, E. N. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.878075 · Cited by 198
Feasibility of Outpatient Fully Integrated Closed-Loop Control
Kovatchev, B. P., Renard, E., Cobelli, C., Zisser, H. C., Keith-Hynes, P., Anderson, S. M., Brown, S. A., Chernavvsky, D. R., Breton, M. D., Farret, A., et al. (2013) · Diabetes Care · doi:10.2337/dc12-1965 · Cited by 177
Self-citationBlood glucose control for type I diabetes mellitus: A robust tracking H∞ problem
Ruiz-Velázquez, E., Femat, R., & Campos-Delgado, D. U. (2004) · Control Engineering Practice · doi:10.1016/j.conengprac.2003.12.004 · Cited by 167
A critical review of mathematical models and data used in diabetology
Boutayeb, A., & Chetouani, A. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-43 · Cited by 126
Dudde, R., Vering, T., Piechotta, G., & Hintsche, R. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.864477 · Cited by 47
“Several closed-loop control algorithms for a SC infusion versus SC sensing setup have been reported [ 16 ].”
Method
Metadata
- Authors
- Bellazzi, R., Nucci, G., & Cobelli, C.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2001
- Volume
- 20
- Issue
- 1
- Pages
- 54-64
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2044973797
- Cited by
- 138
- References
- 0
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.