Computer-aided continuous drug infusion: setup and test of a mobile closed-loop system for the continuous automated infusion of insulin
Abstract
For a diabetes mellitus patient, tight control of glucose level is essential. Results are reported of an investigation of the suitability of existing wearable continuous insulin infusors controlled and adjusted by a control algorithm using continuous glucose measurements as input to perform the functionality of an artificial pancreas. Special attention was given to the development of a continuous glucose monitor and to evaluate which quality of input data is necessary for the control algorithm. In clinical trials, it was found that for patients in a controlled environment an autonomously regulating control algorithm leads to an improved adjustment of patient glucose values and less overall insulin infusion as compared with the best fixed preprogrammed insulin infusion profiles of standard pump therapy. For the limited number of cases studied here, functionality of the control algorithm could tolerate some delay between the actual glucose values in the patient interstitial fluid and the algorithm input of up to 30 min. A quasicontinuous glucose measurement delivering actual glucose values every 5-10 min seems to be suited to control an artificial pancreas.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Dudde et al. developed a minimally-invasive wearable closed-loop quasi-continuous drug infusion system that measures blood glucose levels and infuses insulin automatically.
“For example, Dudde et al. [30] developed a minimally-invasive wearable closed-loop quasi-continuous drug infusion system that measures blood glucose levels and infuses insulin automatically.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [30]
The Dudde et al. device has integrated Bluetooth communication capability for displaying and logging data and receiving commands from a personal digital assistant (PDA) device.
“The device has integrated Bluetooth communication capability for displaying and logging data and receiving commands from a personal digital assistant (PDA) device.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [30]
The glucose monitor consists of a novel silicon sensor that continuously measures glucose levels using a microperfusion technique.
“The glucose monitor consists of a novel silicon sensor that continuously measures glucose levels using a microperfusion technique and continuous infusion of insulin is achieved by a modified advanced insulin pump.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [30]
Continuous infusion of insulin in the Dudde et al. system is achieved by a modified advanced insulin pump.
“The glucose monitor consists of a novel silicon sensor that continuously measures glucose levels using a microperfusion technique and continuous infusion of insulin is achieved by a modified advanced insulin pump.”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [30]
Cites
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274 · see citing works
Self-citationThe MiniMed Continuous Glucose Monitoring System
Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214078 · Cited by 393 · see citing works
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390 · see citing works
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224 · see citing works
Continuous Subcutaneous Glucose Monitoring in Diabetic Patients
Maran, A., Crepaldi, C., Tiengo, A., Grassi, G., Vitali, E., Pagano, G., Bistoni, S., Calabrese, G., Santeusanio, F., Leonetti, F., et al. (2002) · Diabetes Care · doi:10.2337/diacare.25.2.347 · Cited by 198 · see citing works
Glucose monitoring: state of the art and future possibilities
Wilkins, E. S., & Atanasov, P. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00046-1 · Cited by 180 · see citing works
The subcutaneous route to insulin dependent diabetes therapy
Bellazzi, R., Nucci, G., & Cobelli, C. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897828 · Cited by 139 · see citing works
Influence of inflammatory cells and serum on the performance of implantable glucose sensors
Gerritsen, M., Jansen, J. A., Kros, A., Vriezema, D. M., Sommerdijk, N. A. J. M., Nolte, R. J. M., Lutterman, J. A., van Hövell, S. W. F. M., & van der Gaag, A. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200101)54:1 · Cited by 89 · see citing works
Trajanoski, Z., Brunner, G. A., Schaupp, L. A., Ellmerer, M., Wach, P., Pieber, T. R., Kotanko, P., & Skrabal, F. (1997) · Diabetes Care · doi:10.2337/diacare.20.7.1114 · Cited by 66 · see citing works
Shichiri, M., Sakakida, M., Nishida, K., & Shimoda, S. (1998) · Artificial Organs · doi:10.1046/j.1525-1594.1998.06043.x · Cited by 66 · see citing works
Subcutaneous Continuous Glucose Monitoring
Jungheim, K., Wientjes, K. J. C., Heinemann, L., Lodwig, V., Koschinsky, T., Schoonen, A. J. M., & for the glucose monitoring study group (2001) · Diabetes Care · doi:10.2337/diacare.24.9.1696 · Cited by 60 · see citing works
Novel micromachined silicon sensor for continuous glucose monitoring
Piechotta, G., Albers, J., & Hintsche, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.02.008 · Cited by 48 · see citing works
Self-citationAndreassen, S., Aguilera, E. J. G., & Carson, E. R. (2002) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(02)00033-0 · Cited by 11 · see citing works
The Promise of Technology in the Management of the Patient with Diabetes
Colloff, E. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091599316793 · Cited by 5 · see citing works
Editorial: Welcome to Diabetes Technology & Therapeutics
Klonoff, D. C. (1999) · Diabetes Technology & Therapeutics · doi:10.1089/152091599317503 · Cited by 5 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396 · see citing works
A Survey on Activity Detection and Classification Using Wearable Sensors
Cornacchia, M., Ozcan, K., Zheng, Y., & Velipasalar, S. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2628346 · Cited by 427 · see citing works
Chronobiology in the endocrine system
Haus, E. L. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.01.001 · Cited by 222 · see citing works
Trovato, V., Sfameni, S., Rando, G., Rosace, G., Libertino, S., Ferri, A., & Plutino, M. R. (2022) · Molecules · doi:10.3390/molecules27175709 · Cited by 91 · see citing works
The Artificial Pancreas: How Sweet Engineering Will Solve Bitter Problems
Klonoff, D. C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100112 · Cited by 84 · see citing works
Modular Artificial β-Cell System: A Prototype for Clinical Research
Dassau, E., Zisser, H., Palerm, C. C., Buckingham, B. A., Jovanovic, L. G., & Doyle, F. J. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200518 · Cited by 80 · see citing works
Review and Analysis of Blood Glucose (BG) Models for Type 1 Diabetic Patients
Balakrishnan, N. P., Rangaiah, G. P., & Lakshminarayanan, S. (2011) · Industrial & Engineering Chemistry Research · doi:10.1021/ie2004779 · Cited by 73 · see citing works
The INCA System: A Further Step Towards a Telemedical Artificial Pancreas
Aguilera, E. J. G., Hernando, M. E., Vering, T., Rigla, M., Bott, O. J., García-Sáez, G., Pretschner, D. P., Brugués, E., Schnell, O., Patte, C., et al. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.902162 · Cited by 71 · see citing works
Self-citationKondepati, V. R., & Heise, H. M. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1229-8 · Cited by 71 · see citing works
Wearable Intelligent Systems for E-Health
Poon, C. C. Y., Liu, Q., Gao, H., Lin, W.-H., & Zhang, Y. (2011) · Journal of Computing Science and Engineering · doi:10.5626/jcse.2011.5.3.246 · Cited by 50 · see citing works
Wearable and digital devices to monitor and treat metabolic diseases
Keshet, A., Reicher, L., Bar, N., & Segal, E. (2023) · Nature Metabolism · doi:10.1038/s42255-023-00778-y · Cited by 51 · see citing works
Biological Rhythms, Drug Delivery, and Chronotherapeutics
Smolensky, M. H., Siegel, R. A., Haus, E. L., Hermida, R. C., & Portaluppi, F. (2011) · Springer eBooks · doi:10.1007/978-1-4614-0881-9_13 · Cited by 45 · see citing works
Continuous Drug Infusion for Diabetes Therapy: A Closed-Loop Control System Design
Chen, J., Cao, K., Sun, Y., Xiao, Y., & Su, X. (2007) · EURASIP Journal on Wireless Communications and Networking · doi:10.1155/2008/495185 · Cited by 44 · see citing works
A Survey of Insulin-Dependent Diabetes—Part II: Control Methods
Takahashi, D., Yang, X., & Hu, F. (2008) · International Journal of Telemedicine and Applications · doi:10.1155/2008/739385 · Cited by 44 · see citing works
A Survey of Insulin-Dependent Diabetes—Part I: Therapies and Devices
Takahashi, D., Xiao, Y., Hu, F., & Lewis, M. (2008) · International Journal of Telemedicine and Applications · doi:10.1155/2008/639019 · Cited by 31 · see citing works
Deep learning fuzzy immersion and invariance control for type-I diabetes
Mosavi, A. H., Mohammadzadeh, A., Sakthivel, R., Zhang, C., Reuter, U., Kovács, L., & Adeli, H. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105975 · Cited by 23 · see citing works
Recent progress in mechanical artificial pancreas
Hoshino, M., Haraguchi, Y., Mizushima, I., & Sakai, M. (2009) · Journal of Artificial Organs · doi:10.1007/s10047-009-0463-6 · Cited by 23 · see citing works
Generalized Type-2 Fuzzy Control for Type-I Diabetes: Analytical Robust System
Yan, S., Alattas, K. A., Bakouri, M., Alanazi, . K., Mohammadzadeh, A., Mobayen, S., Zhilenkov, A., & Guo, W. (2022) · Mathematics · doi:10.3390/math10050690 · Cited by 22 · see citing works
Wireless sensor network-enabled intravenous infusion monitoring
Zhang, Y., Zhang, S. F., Ji, Y., & Wu, G. (2011) · IET Wireless Sensor Systems · doi:10.1049/iet-wss.2011.0031 · Cited by 19 · see citing works
Intravenous infusion monitoring system based on WSN
Zhang, Y., Zhang, S., Ji, Y., & Wu, G. (2010) · IET International Conference on Wireless Sensor Network (IET-WSN) · doi:10.1049/cp.2010.1024 · Cited by 18 · see citing works
A switching control strategy for the attenuation of blood glucose disturbances
Markakis, M. G., Mitsis, G. D., Papavassilopoulos, G. P., Ioannou, P., & Marmarelis, V. Z. (2009) · Optimal Control Applications and Methods · doi:10.1002/oca.900 · Cited by 16 · see citing works
Short Text Message Based Infusion Fluid Level Monitoring System
Safitri, M., Fonseca, H. D., & Loniza, E. (2020) · Journal of Robotics and Control (JRC) · doi:10.18196/jrc.2253 · Cited by 14 · see citing works
Artificial Pancreas Coupled Vital Signs Monitoring for Improved Patient Safety
Khan, Z. H., Khan, Z. H., & Khan, Z. H. (2012) · Arabian Journal for Science and Engineering · doi:10.1007/s13369-012-0456-2 · Cited by 14 · see citing works
Adaptive Type-2 Fuzzy Control for Regulation of Glucose Level in Type 1 Diabetes
Forooshani, R. Z., Siahi, M., & Ramezani, A. (2019) · IETE Journal of Research · doi:10.1080/03772063.2019.1595183 · Cited by 11 · see citing works
Diagnostics, Theragnostics, and the Personal Health Server
Armstrong, D. G., & Giovinco, N. A. (2011) · Foot & Ankle Specialist · doi:10.1177/1938640010395750 · Cited by 9 · see citing works
Machine Learning in Wearable Healthcare Devices
Sureja, N., Mehta, K., Shah, V., & Patel, G. M. (2023) · Springer eBooks · doi:10.1007/978-981-99-0393-1_13 · Cited by 6 · see citing works
Gui, H., & Liu, J. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1802.01747 · Cited by 11 · see citing works
Moon, H. S., & Jang, E. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00107-x · Cited by 4 · see citing works
Body Fitness Monitoring Using IoT Device
Govinda, K. (2018) · Advances in healthcare information systems and administration book series · doi:10.4018/978-1-5225-5036-5.ch009 · Cited by 4 · see citing works
Reconfigurable hardware for patient monitoring systems
Koundinya, P., Majgi, S. M., Vinod, S., Devaraj, D., & Reddy, B. M. K. (2014) · International Conference on Information Communication and Embedded Systems · doi:10.1109/icices.2014.7033774 · Cited by 3 · see citing works
Non-Invasive IoT-Based Anaesthesia Control System
Khattar, R., Srinivas, S. B., Sharmila, A., & Balaganapathy, S. (2021) · Innovations in Power and Advanced Computing Technologies (i-PACT) · doi:10.1109/i-pact52855.2021.9696586 · Cited by 3 · see citing works
Automated Blook Glucose Management Techniques Through Micro-Sensors
Hu, F., LEWIS, M., & Xiao, Y. (2008) · Auerbach Publications eBooks · doi:10.1201/9781420060478-15 · Cited by 3 · see citing works
Body Area Sensing Networks for Remote Health Monitoring
Biswas, D., Cranny, A., & Maharatna, K. (2015) · Springer eBooks · doi:10.1007/978-3-319-21293-7_4 · Cited by 2 · see citing works
Qaisar, S., Khan, S., & Imtiaz, S. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-31137-6_26 · Cited by 2 · see citing works
Micromachined Amperometric Cells for Continuous Monitoring of Glucose and Lactate
Dudde, R., Piechotta, G., & Hintsche, R. (2006) · Transdisciplinary Conference on Distributed Diagnosis and Home Healthcare (D2H2) · doi:10.1109/ddhh.2006.1624782 · Cited by 2 · see citing works
Self-citationImplantable Drug Delivery System
Upadhyay, S., Soni, S., Shukla, T., Jain, G., Thakar, A., Chaurasiya, H., & Pandey, S. P. (2024) · Springer eBooks · doi:10.1007/978-981-97-4970-6_6 · Cited by 1 · see citing works
Wireless monitoring system via ZigBee in ICUs
Lin, S., Liu, Q., Wu, X., Li, S., & Zhao, Z. (2008) · Springer eBooks · doi:10.1007/978-3-540-79039-6_90 · Cited by 1 · see citing works
Liquid Metal Enabled Wearable Electronics
Liu, J., & Yi, L. (2018) · Springer series in biomaterials science and engineering · doi:10.1007/978-981-10-5607-9_14 · Cited by 1 · see citing works
Human body interaction driven wearable technology for vital signal sensing
Jacob, T. P., Pravin, A., Manikandan, R., Kumar, A., & Gupta, D. K. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-85854-0.00001-0 · Cited by 1 · see citing works
Nimi, W. S., Jose, P. S. H., Jose, P. S. H., Jegan, R., & El‐Shahat, A. (2022) · International Journal of Reliable and Quality E-Healthcare · doi:10.4018/ijrqeh.298632 · Cited by 2 · see citing works
Han, S. W., & Kim, Y.-N. (2015) · Arrhythmia · doi:10.18501/arrhythmia.2015.027 · Cited by 1 · see citing works
Quantitative motor assessment in patients with mobility limiting conditions using wearable sensors
Patel, S. (2012) · doi:10.17760/d20002546 · Cited by 2 · see citing works
Automatic Medical Fluid Infusion System using LabVIEW Real-Time
N.PAVAN, K. C. V. M. S., Vinod, S., M, K. R. B., Majgi, S. M., & Devaraj, D. (2013) · International Conference on Electronic Design
Doctor Controllable Artificial Pancreas System
Arivan, R. V., Harish Kumar, S., & Subhashini, A. (2018) · International Journal of Innovative Research in Applied Sciences and Engineering · doi:10.29027/ijirase.v1.i12.2018.237-240
Automated Blood Glucose Management Techniques Through Micro-Sensors
Xiao, Y., Hu, F., & Lewis, M. (2008) · Auerbach Publications eBooks · doi:10.1201/9781420060478.ch7
(2015) · CRC Press eBooks · doi:10.1201/b19358-2
Ren, D., Li, X., Guo, S., Li, Y., & Zhou, B. (2026) · Annals of Biomedical Engineering · doi:10.1007/s10439-026-04329-w
- Authors
- Dudde, R., Vering, T., Piechotta, G., & Hintsche, R.
- Affiliations
- Fraunhofer Institute for Silicon Technology (DE)
- Venue
- IEEE Transactions on Information Technology in Biomedicine
- Published
- 2006-04
- Volume
- 10
- Issue
- 2
- Pages
- 395-402
- ISSN
- 1089-7771 (ISSN-L)
- 1558-0032
- OpenAlex
- W2152908566
- Cited by
- 47
- References
- 15
- Citations by year
- 2026: 1 · 2024: 1 · 2023: 2 · 2022: 5 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 4 · 2016: 1 · 2015: 3 · 2014: 1 · 2013: 1 · 2012: 4
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
- PubMed (publishedVersion)
- Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Health Sciences › Medicine › Surgery › Pancreatic function and diabetes
- Keywords
- continuous insulin infusion, artificial pancreas, continuous glucose monitoring, diabetes mellitus, glycemic control, control algorithms, insulin dose reduction
- MeSH terms
- Algorithms, Ambulatory Care, Artificial Intelligence, Blood Glucose, Diabetes Mellitus, Drug Therapy, Computer-Assisted, Equipment Design, Feedback, Humans, Insulin, Insulin Infusion Systems, Blood Glucose Self-Monitoring, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review