The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Dynamic analysis of a three-degrees-of-freedom in-parallel actuated manipulator
Abstract
The dynamic analysis of a three-degrees-of-freedom in-parallel actuated manipulator is presented. The equations of motion have been formulated in joint-space using the Lagrangian approach. The analysis provides the solution to predict the forces required to actuate the links so that the manipulator follows a predetermined trajectory. A dynamic simulation program illustrates the influence of the link dynamics on the actuating force required. An example of tracing a helical path is chosen to illustrate the dynamic simulation and to show that the Cartesian position of the moving platform may be controlled at a sacrifice of orientation freedoms. The dynamic analysis provides a basis for future theoretical research to develop the control scheme, for experimental research to estimate the inertia parameters, and for design optimization of the prototype manipulator.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Robotics mechanics and Control
Craig, J. (1986) · Cited by 5,024
A Platform with Six Degrees of Freedom
Stewart, D. (1965) · Proceedings of the Institution of Mechanical Engineers · doi:10.1243/pime_proc_1965_180_029_02 · Cited by 2,634
Kinematic geometry of mechanisms
Hunt, K. H. (1978) · Medical Entomology and Zoology · Cited by 1,911
Compliance and Force Control for Computer Controlled Manipulators
Mason, M. T. (1981) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1981.4308708 · Cited by 1,542
Automatic Synthesis of Fine-Motion Strategies for Robots
Lozano-Pérez, T., Mason, M. T., & Taylor, R. H. (1984) · The International Journal of Robotics Research · doi:10.1177/027836498400300101 · Cited by 898
Structural Kinematics of In-Parallel-Actuated Robot-Arms
Hunt, K. H. (1983) · Journal of Mechanisms, Transmissions, and Automation in Design · doi:10.1115/1.3258540 · Cited by 860
A Stewart Platform- Based Manipulator: General Theory and Practical Construction
Fichter, E. F. (1986) · The International Journal of Robotics Research · doi:10.1177/027836498600500216 · Cited by 790
Kinematic analysis of a three-degrees-of-freedom in-parallel actuated manipulator
Lee, K.-M., & Shah, D. K. (1988) · IEEE Journal on Robotics and Automation · doi:10.1109/56.796 · Cited by 331
Self-citationThe analysis of fields and torques in spherical induction motors
DAVEY, K. R., Vachtsevanos, G., & Powers, R. (1987) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1987.1064749 · Cited by 136
Using compliance in lieu of sensory feedback for automatic assembly.
Drake, S. (1978) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 123
Feasibility Study of a Platform Type of Robotic Manipulators from a Kinematic Viewpoint
Yang, D. C. H., & Lee, T. W. (1984) · Journal of Mechanisms Transmissions and Automation in Design · doi:10.1115/1.3258578 · Cited by 123
Precise manipulation with endpoint sensing
Taylor, R. H., Hollis, R. L., & Lavin, M. A. (1985) · IBM Journal of Research and Development · doi:10.1147/rd.294.0363 · Cited by 46
Design and construction of a cable-controlled, parallel link manipulator
Landsberger, S. E. (1984) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 42
A compliant device for inserting a peg in a hole
McCallion, H., Johnson, G. R., & Pham, D. T. (1979) · Industrial Robot the international journal of robotics research and application · doi:10.1108/eb004754 · Cited by 41
ADVANCES IN COMPUTER TECHNOLOGY
Arbib, M. A. (1984) · Elsevier eBooks · doi:10.1016/b978-0-12-059046-9.50008-9 · Cited by 10
Podoloff, R. M., Seering, W. P., & Hunter, B. J. (1984) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc.1984.4788348 · Cited by 7
Research works printed but not linked: 10
- dodo, 1986, Inverse dynamics of a platform type of manipulating structure, ASME Design Engineering Technical Conf
- 10.1115/1.3258783 · doi:10.1115/1.3258783
- huang, 1985, Modeling formulation of six-DOF multiloop parallel manipulation: Part 2. Dynamic modeling and example, Proc 4Th IFTONM Symp on Linkage and CAD Design Methods
- huang, 1986, Dynamic force analysis of six-DOF parallel multi-loop robot manipulators, ASME Des Eng Technique Conf
- lee, 1986, A three degrees of freedom inparallel actuated manipulator, Proc Int Conf on Applied Control and Identification
- lim, 1981, Control of a Tendon Arm
- mccallion, 1979, The analysis of a six-degree-of-freedom work station for mechanized assembly, Proc 5th World Congr for the Theory of Machines and Mechanisms, 611
- 10.1109/MCS.1987.1105308 · doi:10.1109/mcs.1987.1105308
- vachetsevanos, 1986, On the development of a novel intelligent roboric manipulator, Proc 1986 IEEE Int Conf on Syst Man Cybern
- bennett, 1968, A Mechanical Wrist for a Robot Arm
Cited by
The Stewart platform manipulator: a review
Dasgupta, B., & Mruthyunjaya, T. S. (2000) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(99)00006-3 · Cited by 715
Micron: An Actively Stabilized Handheld Tool for Microsurgery
MacLachlan, R. A., Becker, B. C., Tabares, J. C., Podnar, G. W., Lobes, L. A., & Riviere, C. N. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2169634 · Cited by 270
Toward active tremor canceling in handheld microsurgical instruments
Riviere, C. N., Ang, W. T., & Khosla, P. K. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817506 · Cited by 245
An Active Hand-Held Instrument for Enhanced Microsurgical Accuracy
Ang, W. T., Riviere, C. N., & Khosla, P. K. (2000) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-40899-4_91 · Cited by 52
Metadata
- Authors
- Lee, K.-M., & Shah, D. K.
- Venue
- IEEE Journal on Robotics and Automation
- Published
- 1988-06
- Volume
- 4
- Issue
- 3
- Pages
- 361-367
- ISSN
- 0882-4967 (ISSN-L)
- OpenAlex
- W2129264762
- Cited by
- 446
- References
- 16
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.