The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
A fundamental limit on delay estimation using partially correlated speckle signals
Abstract
Delay estimation is used in ultrasonic imaging to estimate blood or soft tissue motion, to measure echo arrival time differences for phase aberration correction, and to estimate displacement for tissue elasticity measurements. In each of these applications delay estimation is performed using speckle signals which are at least partially decorrelated relative to one another. Delay estimates which utilize such data are subject to large errors known as false peaks and smaller magnitude errors known as jitter. While false peaks can sometimes be removed through nonlinear processing, jitter errors place a fundamental limit on the performance of delay estimation techniques. The authors apply the Cramer-Rao Lower Bound to derive an analytical expression which predicts the magnitude of jitter errors incurred when estimating delays using radio frequency (RF) data from speckle targets. The analytical expression presented includes the effects of signal decorrelation due to physical processes, corruption by electronic noise, and a number of other factors. Simulation results are presented which show that the performance of the normalized cross correlation algorithm closely matches theoretical predictions. These results indicate that for poor signal to noise ratios (0 dB) a small improvement in signal to noise ratio can dramatically reduce jitter magnitude. At high signal to noise ratios (30 dB) small amounts of signal decorrelation can significantly increase the magnitude of jitter errors.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The generalized correlation method for estimation of time delay
Knapp, C., & Carter, G. (1976) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1976.1162830 · Cited by 4,433 · cited 2×
“Carter and Knapp derived a generalized expression for the jitter magnitude when stochastic signals (such as speckle) are used in high signal to noise ratio environments [16].”
BackgroundResultElastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Kasai, C., Namekawa, K., Koyano, A., & Omoto, R. (1985) · IEEE Transactions on Sonics and Ultrasonics · doi:10.1109/t-su.1985.31615 · Cited by 1,255
Coherence and time delay estimation
Carter, G. C. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13723 · Cited by 1,200
Internal displacement and strain imaging using ultrasonic speckle tracking
O'Donnell, M., Skovoroda, A. R., Shapo, B. M., & Emelianov, S. Y. (1994) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.285465 · Cited by 699
Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
Kasai, C., & Namekawa, K. (1985) · IEEE 1985 Ultrasonics Symposium · doi:10.1109/ultsym.1985.198654 · Cited by 573
Flax, S. W., & O’Donnell, M. (1988) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.9333 · Cited by 483
A novel method for angle independent ultrasonic imaging of blood flow and tissue motion
Bohs, L. N., & Trahey, G. E. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.133210 · Cited by 438
Self-citation(1993) · NDT & E International · doi:10.1016/0963-8695(93)90667-j · Cited by 395
An overview on the time delay estimate in active and passive systems for target localization
Quazi, A. (1981) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1981.1163618 · Cited by 393
Cited by
Ultrafast ultrasound localization microscopy for deep super-resolution vascular imaging
Errico, C., Pierre, J., Pezet, S., Desailly, Y., Lenkei, Z., Couture, O., & Tanter, M. (2015) · Nature · doi:10.1038/nature16066 · Cited by 1,349
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Self-citationElastography: Ultrasonic estimation and imaging of the elastic properties of tissues
Ophir, J., Alam, S. K., Garra, B., Kallel, F., Konofagou, E., Krouskop, T., & Varghese, T. (1999) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411991534933 · Cited by 784
On the feasibility of remote palpation using acoustic radiation force
Nightingale, K. R., Palmeri, M. L., Nightingale, R. W., & Trahey, G. E. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1378344 · Cited by 731
Self-citationQuantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Palmeri, M. L., Wang, M. H., Dahl, J. J., Frinkley, K. D., & Nightingale, K. R. (2008) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2007.10.009 · Cited by 683
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
A Least-Squares Strain Estimator for Elastography
Kallel, F., & Ophir, J. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900303 · Cited by 432
An Overview of Elastography-An Emerging Branch of Medical Imaging
Sarvazyan, A., J. Hall, T., W. Urban, M., Fatemi, M., R. Aglyamov, S., & S. Garra, B. (2011) · Current Medical Imaging Reviews · doi:10.2174/157340511798038684 · Cited by 428
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Rapid tracking of small displacements with ultrasound
Pinton, G. F., Dahl, J. J., & Trahey, G. E. (2006) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2006.1642509 · Cited by 389
Self-citationA fast normalized cross-correlation calculation method for motion estimation
Luo, J., & Konofagou, E. E. (2010) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2010.1554 · Cited by 384
Speckle tracking methods for ultrasonic elasticity imaging using short-time correlation
Lubinski, M. A., Emelianov, S. Y., & O'Donnell, M. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.741427 · Cited by 379
A theoretical framework for performance characterization of elastography: the strain filter
Varghese, T., & Ophir, J. (1997) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.585212 · Cited by 338
Elastography: Ultrasonic imaging of tissue strain and elastic modulus in vivo
Ophir, J., Cespedes, I., Garra, B., Ponnekanti, H., Huang, Y., & Maklad, N. (1996) · European Journal of Ultrasound · doi:10.1016/0929-8266(95)00134-4 · Cited by 287
Song, P., Trzasko, J. D., Manduca, A., Huang, R., Kadirvel, R., Kallmes, D. F., & Chen, S. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2017.2778941 · Cited by 285
Assessment of Liver Viscoelasticity by Using Shear Waves Induced by Ultrasound Radiation Force
Chen, S., Sanchez, W., Callstrom, M. R., Gorman, B., Lewis, J. T., Sanderson, S. O., Greenleaf, J. F., Xie, H., Shi, Y., Pashley, M., et al. (2013) · Radiology · doi:10.1148/radiol.12120837 · Cited by 258
Udesen, J., Gran, F., Hansen, K., Jensen, J. A., Thomsen, C., & Nielsen, M. B. (2008) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.858 · Cited by 254
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
A Survey of Time Delay Estimation Performance Bounds
Sadler, B. M., & Kozick, R. J. (2006) · Fourth IEEE Workshop on Sensor Array and Multichannel Processing, 2006. · doi:10.1109/sam.2006.1706138 · Cited by 62
Metadata
- Authors
- Walker, W. F., & Trahey, G. E.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1995-03
- Volume
- 42
- Issue
- 2
- Pages
- 301-308
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2102248332
- Cited by
- 479
- References
- 17
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.