The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering
Abstract
Transducer design and phased array beam steering are developed for a volumetric ultrasound scanner that enables the 3-D visualization of dynamic structures in real time. The authors describe the design considerations and preliminary evaluation of a high-speed, online volumetric ultrasound imaging system that uses the principles of pulse-echo, phased array scanning with a 2-D array transducer. Several 2-D array designs are analyzed for resolution and main lobe-side lobe ratio by simulation using 2-D fast Fourier transform methods. Fabrication techniques are described for 2-D array transducer. Experimental measurements of pulse-echo point spread responses for 2-D arrays agree with the simulations. Measurements of pulse-echo sensitivity, bandwidth, and crosstalk are included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Jenkins, F. A., White, H. E., & Brukhard, D. G. (1958) · American Journal of Physics · doi:10.1119/1.1996127 · Cited by 1,174
High-speed ultrasound volumetric imaging system. II. Parallel processing and image display
von Ramm, O. T., Smith, S. W., & Pavy, H. G. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68467 · Cited by 396
Self-citationBeam Steering with Linear Arrays
Von Ramm, O. T., & Smith, S. W. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325149 · Cited by 262
Self-citationCardiac imaging using a phased array ultrasound system. I. System design.
vonRamm, O. T., & Thurstone, F. L. (1976) · Circulation · doi:10.1161/01.cir.53.2.258 · Cited by 186
Self-citationApplication of Echo-Ranging Techniques to the Determination of Structure of Biological Tissues
Wild, J. J., & Reid, J. M. (1952) · Science · doi:10.1126/science.115.2983.226 · Cited by 167
Multidimensional ultrasonic imaging for cardiology
McCann, H., Sharp, J. C., Kinter, T. M., McEwan, C. N., Barillot, C., & Greenleaf, J. F. (1988) · Proceedings of the IEEE · doi:10.1109/5.9652 · Cited by 98
Real-time orthogonal mode scanning of the heart. I. System Design
Snyder, J. E., KISSLO, J. A., & von Ramm, O. T. (1986) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(86)80147-4 · Cited by 58
Cited by
Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography
Montaldo, G., Tanter, M., Bercoff, J., Benech, N., & Fink, M. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1067 · Cited by 1,814
Ultrafast imaging in biomedical ultrasound
Tanter, M., & Fink, M. (2014) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2014.2882 · Cited by 1,151
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Merging virtual objects with the real world: seeing ultrasound imagery within the patient
Bajura, M., Fuchs, H., & Ohbuchi, R. (1992) · Proceedings of the 19th annual conference on Computer graphics and interactive techniques · doi:10.1145/133994.134061 · Cited by 520
A new method for estimation of velocity vectors
Jensen, J. A., & Munk, P. (1998) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.677749 · Cited by 428
Metadata
- Authors
- Smith, S. W., Pavy, H. G., & von Ramm, O. T.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1991-03
- Volume
- 38
- Issue
- 2
- Pages
- 100-108
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2144036540
- Cited by
- 504
- References
- 8
- FWCI
- 18.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.