The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Beam steering with pulsed two-dimensional transducer arrays
Abstract
The major problem facing the development of 2-D arrays for imaging is the complexity arising from the large number of elements anticipated in such transducers. The authors have undertaken a theoretical investigation of the focusing and steering properties of pulsed 2-D arrays to characterize the parameters required for medical imaging, such as element size, spacing, and number of elements. Details of the computational methods employed are presented, as well as a discussion of the steered beam properties of wideband 2-D arrays. The effects of apodization and element cross-coupling on the beam properties of a 2-D transducer array are examined. The beam properties of various sparse arrays with elements randomly distributed over the aperture of the transducer are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
O'Neil, H. T. (1949) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906542 · Cited by 575
Beam Steering with Linear Arrays
Von Ramm, O. T., & Smith, S. W. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325149 · Cited by 262
Real time volumetric ultrasound imaging system
von Ramm, O. T., & Smith, S. W. (1990) · Journal of Digital Imaging · doi:10.1007/bf03168124 · Cited by 247
Real-time volumetric ultrasound imaging system
von Ramm, O. T., & Smith, S. W. (1990) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.18779 · Cited by 40
Cited by
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Camacho, J., Parrilla, M., & Fritsch, C. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1128 · Cited by 525
3-D ultrasound imaging: a review
Fenster, A., & Downey, D. B. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.544511 · Cited by 403
Metamaterial bricks and quantization of meta-surfaces
Memoli, G., Caleap, M., Asakawa, M., Sahoo, D. R., Drinkwater, B. W., & Subramanian, S. (2017) · Nature Communications · doi:10.1038/ncomms14608 · Cited by 256
Metadata
- Authors
- Turnbull, D. H., & Foster, F. S.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1991-07
- Volume
- 38
- Issue
- 4
- Pages
- 320-333
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2127272691
- Cited by
- 303
- References
- 5
- FWCI
- 12.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Beam steering with pulsed two-dimensional transducer arrays. https://app.cochat.ai/papers/10.1109/58.84270
- The paper
- Turnbull, D. H., & Foster, F. S. (1991). Beam steering with pulsed two-dimensional transducer arrays. IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. https://doi.org/10.1109/58.84270
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.