The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
3-D ultrasound imaging: a review
Abstract
The development of 3-D ultrasound imaging is a way to address the disadvantages of conventional ultrasound imaging. In this article the authors review approaches that have been attempted in the development of 3-D ultrasound imaging such as 3-D B-mode, color Doppler, and power Doppler systems. Acquisition, reconstruction, and rendering techniques for 3-D imaging are discussed, as well as applications and limitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Efficient ray tracing of volume data
Levoy, M. (1990) · ACM Transactions on Graphics · doi:10.1145/78964.78965 · Cited by 991
Review of MR image segmentation techniques using pattern recognition
Bezdek, J. C., Hall, L. O., & Clarke, L. P. (1993) · Medical Physics · doi:10.1118/1.597000 · Cited by 953
Magnetic Position and Orientation Tracking System
Raab, F., Blood, E., Steiner, T., & Jones, H. (1979) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1979.308860 · Cited by 614
Levine, R. A., Handschumacher, M. D., Sanfilippo, A. J., Hagege, A. A., Harrigan, P., Marshall, J. E., & Weyman, A. E. (1989) · Circulation · doi:10.1161/01.cir.80.3.589 · Cited by 556
High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering
Smith, S. W., Pavy, H. G., & von Ramm, O. T. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68466 · Cited by 504
Three dimensional CT reconstruction images for craniofacial surgical planning and evaluation.
Vannier, M. W., Marsh, J. L., & Warren, J. O. (1984) · Radiology · doi:10.1148/radiology.150.1.6689758 · Cited by 467
A discrete dynamic contour model
Lobregt, S., & Viergever, M. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.370398 · Cited by 426
High-speed ultrasound volumetric imaging system. II. Parallel processing and image display
von Ramm, O. T., Smith, S. W., & Pavy, H. G. (1991) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.68467 · Cited by 396
Shattuck, D. P., Weinshenker, M. D., Smith, S. W., & von Ramm, O. T. (1984) · The Journal of the Acoustical Society of America · doi:10.1121/1.390734 · Cited by 395
Interactive display and analysis of 3-D medical images
Robb, R. A., & Barillot, C. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34710 · Cited by 314
Cited by
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Self-citationQiu, Y., Gigliotti, J., Wallace, M., Griggio, F., Demore, C., Cochran, S., & Trolier-McKinstry, S. (2015) · Sensors · doi:10.3390/s150408020 · Cited by 395
A Review on Real-Time 3D Ultrasound Imaging Technology
Huang, Q., & Zeng, Z. (2017) · BioMed Research International · doi:10.1155/2017/6027029 · Cited by 334
Tunable image quality control of 3-D ultrasound using switchable CycleGAN
Huh, J., Khan, S., Choi, S., Shin, D., Lee, J. E., Lee, E. S., & Ye, J. C. (2023) · Medical Image Analysis · doi:10.1016/j.media.2022.102651 · Cited by 14
An Angle-Independent Cross-Sectional Doppler Method for Flow Estimation in the Common Carotid Artery
van Knippenberg, L., van Sloun, R. J. G., Shulepov, S., Bouwman, R. A., & Mischi, M. (2020) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2020.2975315 · Cited by 11
Metadata
- Authors
- Fenster, A., & Downey, D. B.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 1996
- Volume
- 15
- Issue
- 6
- Pages
- 41-51
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W1975214511
- Cited by
- 403
- References
- 75
- FWCI
- 12.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3-D ultrasound imaging: a review. https://app.cochat.ai/papers/10.1109/51.544511
- The paper
- Fenster, A., & Downey, D. B. (1996). 3-D ultrasound imaging: a review. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/51.544511
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.