Operation of fault tolerant machines with winding failures
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper examines winding faults in a demonstrator drive, based on a specification for an aircraft fuel pump. This drive has been designed with a degree of inherent fault tolerance and is capable of continued operation in the presence of a variety of faults. Some of the most severe faults arise from winding insulation failure within a phase of the machine. A method of detecting turn to turn short circuits which can result from winding insulation breakdown is presented, along with a strategy for continued post fault operation of the drive. The detection method operates in real time, requires no additional sensors and is sufficiently sensitive to detect even a single shorted turn.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fault-tolerant permanent magnet machinedrives
Mecrow, B. C., Jack, A. G., Haylock, J. A., & Coles, J. (1996) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19960796 · Cited by 376
Self-citation
Cited by
Overview of Electric Motor Technologies Used for More Electric Aircraft (MEA)
Cao, W., Mecrow, B. C., Atkinson, G. J., Bennett, J. W., & Atkinson, D. J. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2165453 · Cited by 1,026
Self-citationOn advantages of multi-phase machines
Parsa, L. (2005) · 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005. · doi:10.1109/iecon.2005.1569139 · Cited by 298
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Design and Testing of a Four-Phase Fault-Tolerant Permanent-Magnet Machine for an Engine Fuel Pump
Mecrow, B. C., Jack, A. G., Atkinson, D. J., Green, S. R., Atkinson, G. J., King, A., & Green, B. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.832074 · Cited by 252
Self-citationSynchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
Metadata
- Authors
- Haylock, J. A., Mecrow, B. C., Jack, A. G., & Atkinson, D. J.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 1999
- Volume
- 14
- Issue
- 4
- Pages
- 1490-1495
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2167516775
- Cited by
- 148
- References
- 1
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operation of fault tolerant machines with winding failures. https://app.cochat.ai/papers/10.1109/60.815095
- The paper
- Haylock, J. A., Mecrow, B. C., Jack, A. G., & Atkinson, D. J. (1999). Operation of fault tolerant machines with winding failures. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/60.815095
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.