The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
A reliable gait phase detection system
Abstract
A new highly reliable gait phase detection system, which can be used in gait analysis applications and to control the gait cycle of a neuroprosthesis for walking, is described. The system was designed to detect in real-time the following gait phases: stance, heel-off, swing, and heel-strike. The gait phase detection system employed a gyroscope to measure the angular velocity of the foot and three force sensitive resistors to assess the forces exerted by the foot on the shoe sole during walking. A rule-based detection algorithm, which was running on a portable microprocessor board, processed the sensor signals. In the presented experimental study ten able body subjects and six subjects with impaired gait tested the device in both indoor and outdoor environments (0-25 degrees C). The subjects were asked to walk on flat and irregular surfaces, to step over small obstacles, to walk on inclined surfaces, and to ascend and descend stairs. Despite the significant variation in the individual walking styles the system achieved an overall detection reliability above 99% for both subject groups for the tasks involving walking on flat, irregular, and inclined surfaces. In the case of stair climbing and descending tasks the success rate of the system was above 99% for the able body subjects and above 96 % for the subjects with impaired gait. The experiments also showed that the gait phase detection system, unlike other similar devices, was insensitive to perturbations caused by nonwalking activities such as weight shifting between legs during standing, feet sliding, sitting down, and standing up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wt, L., Holmquest, H. J., Scot, D., & Dow, M. (1961) · PubMed · Cited by 898
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Surface-stimulation technology for grasping and walking neuroprostheses
Popović, M. R., Keller, T., Papas, I., Dietz, V., & Morari, M. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.897831 · Cited by 180
Self-citationAutomatic stance-swing phase detection from accelerometer data for peroneal nerve stimulation
Willemsen, A. T. M., Bloemhof, F., & Boom, H. B. K. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.64463 · Cited by 169
Application of tilt sensors in functional electrical stimulation
Dai, R., Stein, R. B., Andrews, B. J., James, K. B., & Wieler, M. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506403 · Cited by 167
Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation
Kobetic, R., & Marsolais, E. B. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.313148 · Cited by 165
Gait event detection for FES using accelerometers and supervised machine learning
Williamson, R., & Andrews, B. J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867873 · Cited by 164
Machine learning in control of functional electrical stimulation systems for locomotion
Kostov, A., Andrews, B. J., Popović, D. B., Stein, R. B., & Armstrong, W. W. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.387193 · Cited by 130
Automatic detection of gait events: a case study using inductive learning techniques
Kirkwood, C. A., Andrews, B. J., & Mowforth, P. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90046-0 · Cited by 82
Graupe, D., Kohn, K. H., Kralj, A. R., & Basseas, S. P. (1983) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(83)90100-0 · Cited by 57
Strange, K. D., & Hoffer, J. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.771189 · Cited by 39
Recent Applications of Functional Electrical Stimulation to Stroke Patients in Ljubljana
VODOVNIK, L., Kralj, A. R., STANK, U., Aćimović, R., & Gros, N. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197803000-00009 · Cited by 37
Natural Versus Artificial Sensors Applied in Peroneal Nerve Stimulation
Upshaw, B., & Sinkjær, T. (1997) · Artificial Organs · doi:10.1111/j.1525-1594.1997.tb04655.x · Cited by 27
Experimental Evaluation of the Gyroscope Sensor used in a New Gait Phase Detection System
Pappas, I. P. I., Keller, T., & Popović, M. R. (1999) · Cited by 11
Self-citation
Cited by
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Gait Analysis Using a Shoe-Integrated Wireless Sensor System
Bamberg, S., Benbasat, A. Y., Scarborough, D. M., Krebs, D. E., & Paradiso, J. A. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2007.899493 · Cited by 737
Assessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
Measuring orientation of human body segments using miniature gyroscopes and accelerometers
Luinge, H. J., & Veltink, P. H. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345966 · Cited by 647
Advanced internet of things for personalised healthcare systems: A survey
Qi, J., Yang, P., Min, G., Amft, O., Dong, F., & Xu, L. (2017) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2017.06.018 · Cited by 406
Metadata
- Authors
- Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2001-06
- Volume
- 9
- Issue
- 2
- Pages
- 113-125
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2124517686
- Cited by
- 495
- References
- 14
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.