The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Surface-tension-driven microactuation based on continuous electrowetting
Abstract
This paper describes the first microelectromechanical systems (MEMS) demonstration device that adopts surface tension as the driving force. A liquid-metal droplet can be driven in an electrolyte-filled capillary by locally modifying the surface tension with electric potential. We explore this so-called continuous electrowetting phenomenon for MEMS and present crucial design and fabrication technology that reduce the surface-tension-driving principle, inherently powerful in microscale, into practice. The key issues that are identified and investigated include the problem of material compatibility, electrode polarization, and electrolysis, as well as the micromachining process. Based on the results from the initial test devices and the design concept for a long-range movement of the liquid-metal droplet, we demonstrate a liquid micromotor, an electrolyte and liquid-metal droplets rotating along a microchannel loop. Smooth and wear-free rotation of the liquid system is shown at a speed of /spl sim/40 mm/s (or 420 r/min along a 2-mm loop) with a driving voltage of only 2.8 V and little power consumption (10-100 /spl mu/W).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical chemistry of surfaces
(1998) · Choice Reviews Online · doi:10.5860/choice.35-4499 · Cited by 11,648
Principles of colloid and surface chemistry
Hiemenz, P. C., & Rajagopalan, R. (1977) · Cited by 3,500
Principles of colloid and surface chemistry
Matijević, E. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90045-6 · Cited by 2,781
The physics and chemistry of surfaces
Adam, N. K. (1938) · Andalas University Repository (Andalas University) · Cited by 1,062
Critical Review: Adhesion in surface micromechanical structures
Maboudian, R., & Howe, R. T. (1997) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.589247 · Cited by 841
The Physics and Chemistry of Surfaces
RIDEAL, E. K. (1942) · Nature · doi:10.1038/150730a0 · Cited by 773
High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Microrobots and micromechanical systems
Trimmer, W. S. N. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)87079-9 · Cited by 414
Bockris, J. O., & Reddy, A. K. N. (1970) · Springer eBooks · doi:10.1007/978-1-4615-7464-4 · Cited by 275
Feynman, R. P. (1993) · Journal of Microelectromechanical Systems · doi:10.1109/84.232589 · Cited by 154
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Electrowetting: from basics to applications
Mugele, F., & Baret, J.-C. (2005) · Journal of Physics: Condensed Matter · doi:10.1088/0953-8984/17/28/r01 · Cited by 2,092
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Metadata
- Authors
- Lee, J., & Kim, C.-J.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2000-06
- Volume
- 9
- Issue
- 2
- Pages
- 171-180
- ISSN
- 1057-7157 (ISSN-L)
- 1941-0158
- OpenAlex
- W2121715744
- Cited by
- 390
- References
- 10
- FWCI
- 11.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.