The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Bent-beam electrothermal actuators-Part I: Single beam and cascaded devices
Abstract
This paper describes electrothermal microactuators that generate rectilinear displacements and forces by leveraging deformations caused by localized thermal stresses. In one manifestation, an electric current is passed through a V-shaped beam anchored at both ends, and thermal expansion caused by joule heating pushes the apex outward. Analytical and finite element models of device performance are presented along with measured results of devices fabricated using electroplated Ni and p/sup ++/ Si as structural materials. A maskless process extension for incorporating thermal and electrical isolation is described. Nickel devices with 410-/spl mu/m-long, 6-/spl mu/m-wide, and 3-/spl mu/m-thick beams demonstrate 10 /spl mu/m static displacements at 79 mW input power; silicon devices with 800-/spl mu/m-long, 13.9-/spl mu/m-wide, and 3.7-/spl mu/m-thick beams demonstrate 5 /spl mu/m displacement at 180 mW input power. Cascaded silicon devices using three beams of similar dimensions offer comparable displacement with 50-60% savings in power consumption. The peak output forces generated are estimated to be in the range from 1 to 10 mN for the single beam devices and from 0.1 to 1 mN for the cascaded devices. Measured bandwidths are /spl ap/700 Hz for both. The typical drive voltages used are /spl les/12 V, permitting the use of standard electronic interfaces that are generally inadequate for electrostatic actuators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laterally Driven Polysilicon Resonant Microstructures
Tang, W. C., Nguyen, T.-C. H., & Howe, R. T. (1989) · Sensors and Actuators · doi:10.1016/0250-6874(89)87098-2 · Cited by 743
Piezoelectric micromotors for microrobots
Flynn, A. M., Tavrow, L. S., Bart, S. F., Brooks, R. A., Ehrlich, D. J., Udayakumar, K. R., & Cross, L. E. (1992) · Journal of Microelectromechanical Systems · doi:10.1109/84.128055 · Cited by 228
Thermo-magnetic metal flexure actuators
Guckel, H., Klein, J., Christenson, T., Skrobis, K., Laudon, M., & Lovell, E. G. (2003) · Technical Digest IEEE Solid-State Sensor and Actuator Workshop · doi:10.1109/solsen.1992.228273 · Cited by 212
Gianchandani, Y. B., & Najafi, K. (1996) · Journal of Microelectromechanical Systems · doi:10.1109/84.485216 · Cited by 177
Self-citationControlled stepwise motion in polysilicon microstructures
Akiyama, T., & Shono, K. (1993) · Journal of Microelectromechanical Systems · doi:10.1109/84.260254 · Cited by 150
Comtois, J. H., Michalicek, M. A., & Barron, C. C. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1997.635213 · Cited by 46
Cited by
Micro-Raman thermometry of thermal flexure actuators
Serrano, J. R., Phinney, L. M., & Kearney, S. P. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/7/004 · Cited by 38
Metadata
- Authors
- Que, L., Park, J.-S., & Gianchandani, Y. B.
- Venue
- Journal of Microelectromechanical Systems
- Published
- 2001-06
- Volume
- 10
- Issue
- 2
- Pages
- 247-254
- ISSN
- 1057-7157 (ISSN-L)
- OpenAlex
- W2124606332
- Cited by
- 348
- References
- 6
- FWCI
- 15.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.