The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation
Abstract
Template stimulation patterns were used for a multichannel functional neuromuscular stimulation (FNS) system to synthesize movements for walking in paraplegia. Rules were developed and tested for tailoring template walking stimulation patterns to individuals. The criteria for effective rule application were based on the degree to which the paraplegic gait approached normal appearance, independence of forward progression, the least amount of upper body support, and the minimum amount of energy used as perceived by the user. The ability of preset microprocessor-controlled stimuli to generate walking in paraplegia were limited by muscle strength, fatigue, and timing of stimulation. Joint moment testing showed that paraplegic subjects had 20-60% of normal strength. In individuals at the lower end of the range, the strength was insufficient to allow independent forward progression. The muscle fatigue effected the strength and timing of joint movements during walking. Timing of hip extensor activation at heel strike was found to be critical for progression. Excessive forces were taken up through arm support, especially with hip and trunk extensor fatigue, and forward lean was essential for progression. Hip and trunk stability was achieved through stiffening by co-contraction and upper body support. This resulted in metabolic energy expenditure as high as four times normal.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Cited by
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Neuromuscular electrical stimulation in neurorehabilitation
Sheffler, L. R., & Chae, J. (2007) · Muscle & Nerve · doi:10.1002/mus.20758 · Cited by 529
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495
Ragnarsson, K. T. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102091 · Cited by 301
Stimulus waveforms for selective neural stimulation
Grill, W. M., & Mortimer, J. T. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.395310 · Cited by 280
Kobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155
Self-citationChae, J., & Hart, R. (1998) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199811000-00013 · Cited by 72
Johnston, T. E., Betz, R. R., Smith, B. T., Benda, B. J., Mulcahey, M. J., Davis, R., Houdayer, T. P., Pontari, M. A., Barriskill, A., & Creasey, G. H. (2005) · Spinal Cord · doi:10.1038/sj.sc.3101797 · Cited by 60
Perspectives on the role of afferent signals in control of motor neuroprostheses
Johnson, K. O., Popović, D., Riso, R. R., Koris, M., Van Doren, C., & Kantor, C. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00003-6 · Cited by 16
Metadata
- Authors
- Kobetic, R., & Marsolais, E. B.
- Venue
- IEEE Transactions on Rehabilitation Engineering
- Published
- 1994-06
- Volume
- 2
- Issue
- 2
- Pages
- 66-79
- ISSN
- 1063-6528 (ISSN-L)
- OpenAlex
- W2126625187
- Cited by
- 165
- References
- 1
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.