CoChat

A comparison between control methods for implanted FES hand-grasp systems

Hart, R.L., Kilgore, K.L., Peckham, P.H. · 1998 · IEEE Transactions on Rehabilitation Engineering
Cited by 128

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Implanted neuroprostheses employing functional electrical stimulation (FES) provide grasp and release to individuals with tetraplegia. This paper describes and compares three methods of controlling the stimulated hand movement: shoulder position, wrist position and myoelectric activity from the wrist extensors. Three experienced neuroprosthesis users were evaluated with each of the control methods by performing a grasp release test (GRT). A significant improvement was found between each functional electrical stimulation (FES) method and tenodesis without FES. No significant difference in overall performance was found between the three FES methods of control. Each method of control demonstrated advantages and disadvantages which depend upon characteristics of the individual patient. Factors which must be considered are injury level, voluntary wrist strength, proximal upper limb strength, the level of cognition of the patient, hand-grasp characteristics, cosmeses, importance of using both arms, and personal preference. Due to the unique characteristics of each controller type, it is advantageous to have each type available for the FES patients to adapt the system to the needs and desires of the individual patient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/86.681187

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Hart, R. L., Kilgore, K. L., & Peckham, P. H.
Venue
IEEE Transactions on Rehabilitation Engineering
Published
1998-06
Volume
6
Issue
2
Pages
208-218
ISSN
1063-6528 (ISSN-L)
OpenAlex
W2148102797
Cited by
128
References
3
FWCI
6.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.