A Review of EEG and MEG Epileptic Spike Detection Algorithms
Open accessThe DOI matches its Crossref record; 80 of the 81 references it cites were found in a registry or an index.
Abstract
Epilepsy is one of the most serious disorders that affect patients' daily lives. When seizures occur, patients cannot control their behaviors, which can lead to serious injuries. With the great advances in recording both electroencephalogram (EEG) and magnetoencephalography (MEG) signals, it has become possible to analyze these signals in an automated manner for information extraction to help in seizure detection and prediction. Both EEG and MEG recordings of epilepsy patients contain spikes that can be used for the localization of epileptogenic zones, efficient onset detection, and even, in some cases, prediction. In this paper, we consider the characteristics of EEG and MEG spikes, present a discussion of the importance of spike detection in both signal modalities, and provide a review of spike detection algorithms. Since EEG signals have been widely used for decades, most of the algorithms presented in this paper cover the EEG spike detection methods. Few works in the literature are dedicated to MEG spike detection. Nevertheless, we assert that with some modifications, a considerable number of EEG spike detection algorithms can be applied to MEG signals. We classify the spike detection algorithms according to the domain used for processing the signal. Finally, we conclude with future research directions and open problems in this area.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This indicates that IENet extracts the features of abnormal discharge as the basis for seizure detection, similar to the prior knowledge based algorithms to manually extract relevant features such as spikes [100].”
From IENet: a robust convolutional neural network for EEG based brain-computer interfaces (2022) · cites this paper as [100]
Citations
Cites
Image Features From Phase Congruency
Kovesi, P. D. (1995) · UWA Profiles and Research Repository (UWA) · Cited by 1,246
Magnetoencephalography for Brain Electrophysiology and Imaging
Baillet, S. (2017) · Nature Neuroscience · doi:10.1038/nn.4504 · Cited by 992
EEG and MEG: Relevance to Neuroscience
Lopes da Silva, F. (2013) · Neuron · doi:10.1016/j.neuron.2013.10.017 · Cited by 900 · cited 1×
“An important difference between EEG and MEG signals is that the decay rate of the magnetic field is higher than that of the electric field [8]–[10].”
BackgroundCohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750 · cited 1×
“To reduce the noise of these signals and yield clean MEG signals, superconducting quantum interference device (SQUID) detectors have been used [5]–[7].”
MethodAutomatic recognition and quantification of interictal epileptic activity in the human scalp EEG
Gotman, J., & Gloor, P. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90063-8 · Cited by 424 · cited 4×
“Gotman and Gloor [30] and Gotman et al.”
BackgroundInfluentialEEG seizure detection and prediction algorithms: a survey
Alotaiby, T. N., Alshebeili, S. A., Alshawi, T., Ahmad, I., & Abd El-Samie, F. E. (2014) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/1687-6180-2014-183 · Cited by 292 · cited 1×
“The wavelet transform has gained popularity in medical signal processing applications, because it translates a signal into an approximation component having most of the signal energy and several detailed components that show sharp transitions in a signal clearly [77].”
BackgroundWavelet preprocessing for automated neural network detection of EEG spikes
Kalayci, T., & Ozdamar, O. (1995) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.376754 · Cited by 264 · cited 4×
“Kalayci and Ozdamar [80] suggested the use of a five-level wavelet transform prior to a neural classifier for epileptic EEG spike detection.”
InfluentialComputer analysis of EEG signals with parametric models
Isaksson, A., Wennberg, A., & Zetterberg, L. H. (1981) · Proceedings of the IEEE · doi:10.1109/proc.1981.11988 · Cited by 204 · cited 1×
“[65] investigated the use of parametric methods, such as autoregressive (AR) and autoregressive moving average (ARMA) models, to create time-invariant models for EEG signals.”
MethodAutomated interictal EEG spike detection using artificial neural networks
Gabor, A. J., & Seyal, M. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90086-w · Cited by 165 · cited 3×
“Gabor and Seyal [41] presented a time-domain spike detection approach adopting an error-back-propagation feed-forward neural network classifier.”
BackgroundMethodInfluentialEnglot, D. J., Nagarajan, S. S., Imber, B. S., Raygor, K. P., Honma, S. M., Mizuiri, D., Mantle, M., Knowlton, R. C., Kirsch, H. E., & Chang, E. F. (2015) · Epilepsia · doi:10.1111/epi.13002 · Cited by 151 · cited 1×
“Therefore, MEG spike detection is a fundamental step in epileptic seizure source localization [13], [14].”
BackgroundAutomatic recognition of inter-ictal epileptic activity in prolonged EEG recordings
Gotman, J., Ives, J. R., & GLOOR, P. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90004-x · Cited by 147 · cited 2×
“[31] developed an automatic spike-recognition method based on breaking down the EEG signal into half-waves and extracting few features such as the amplitude, duration, and sharpness.”
BackgroundMethodState-dependent spike detection: concepts and preliminary results
Gotman, J., & Wang, L. Y. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90151-s · Cited by 129 · cited 1×
“In [33], Gotman and Wang validated their state-dependent method [34] in which the”
MethodWebber, W. R., Litt, B., Wilson, K., & Lesser, R. P. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90069-8 · Cited by 128 · cited 1×
“[38] developed an artificial neural network-based approach for epileptiform discharge detection.”
BackgroundMazzoni, A., Whittingstall, K., Brunel, N., Logothetis, N. K., & Panzeri, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.12.040 · Cited by 124 · cited 1×
“Hence, spike detection algorithms are needed to determine the spike rate in EEG signals [21].”
BackgroundSpike detection II: automatic, perception-based detection and clustering
Wilson, S. B., Turner, C. A., Emerson, R. G., & Scheuer, M. L. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00023-6 · Cited by 122 · cited 1×
“[40] developed a spike detection method using a multiple monotonic neural network (MMNN).”
MethodA comparison of algorithms for detection of spikes in the electroencephalogram
Pang, C. C. C., Upton, A. R. M., Shine, G., & Kamath, M. V. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.809479 · Cited by 121 · cited 1×
“Spike-like activities or artifacts, such as the saccadic spike artifact, may also occur in some channels, and these activities need to be filtered out to reduce false detections [27].”
BackgroundThe saccadic spike artifact in MEG
Carl, C., Açık, A., König, P., Engel, A. K., & Hipp, J. F. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.020 · Cited by 110 · cited 1×
“MEG signals can reveal more information than either alone [18]–[20].”
BackgroundOssadtchi, A., Baillet, S., Mosher, J. C., Thyerlei, D., Sutherling, W., & Leahy, R. M. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.036 · Cited by 104 · cited 1×
“[64] presented a multi-channel MEG spikelocalizationmethod.”
Barkmeier, D. T., Shah, A. K., Flanagan, D., Atkinson, M. D., Agarwal, R., Fuerst, D. R., Jafari‐Khouzani, K., & Loeb, J. A. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.09.023 · Cited by 97 · cited 2×
“[52] presented an automaticmulti-channel interictal spike detection algorithm that mirrored the expert”
MethodSeizure Occurrence and Interspike Interval: Telemetered Electroencephalogram Studies
Stevens, J. R., Lonsbury, B. L., & Goel, S. L. (1972) · Archives of Neurology · doi:10.1001/archneur.1972.00490110043004 · Cited by 97 · cited 1×
“[29] presented the first attempt of automatic epileptic spike recognition over a long recording.”
BackgroundInterictal Spike Detection Using the Walsh Transform
Adjouadi, M., Sanchez, D., Cabrerizo, M., Ayala, M., Jayakar, P., Yaylali, I., & Barreto, A. B. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826642 · Cited by 95 · cited 2×
“Simulated interictal EEG spike morphology [26].”
BackgroundEEG Transient Event Detection and Classification Using Association Rules
Exarchos, T. P., Tzallas, A. T., Fotiadis, D. I., Konitsiotis, S., & Giannopoulos, S. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.872067 · Cited by 92 · cited 1×
“[69] presented an event-detection and -classification approach for EEG transient activities based on association rules.”
BackgroundNonclercq, A., Foulon, M., Verheulpen, D., Cock, C. D., Buzatu, M., Mathys, P., & Bogaert, P. V. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.07.015 · Cited by 90 · cited 3×
“The algorithm implemented in NeuroTrend is the time-domain multi-channel algorithm for the detection of rhythmic and periodic patterns from EEG signals described in [44].”
MethodInfluentialA Kalman filter based methodology for EEG spike enhancement
Oikonomou, V. P., Tzallas, A. T., & Fotiadis, D. I. (2006) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2006.10.003 · Cited by 83 · cited 2×
“Unfortunately, this strategy leads to low detection performance [25], [49].”
BackgroundMethodState dependent spike detection: validation
Gotman, J., & Wang, L. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90127-4 · Cited by 80 · cited 1×
“In [33], Gotman and Wang validated their state-dependent method [34] in which the”
MethodInterictal spike analysis of high-density EEG in patients with partial epilepsy
Wang, G., Worrell, G., Yang, L., Wilke, C., & He, B. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.10.043 · Cited by 76 · cited 1×
“[36] suggested the use of both high- and lowdensity electrodes to detect interictal spikes.”
BackgroundYamazaki, M., Tucker, D. M., Fujimoto, A., Yamazoe, T., Okanishi, T., Yokota, T., Enoki, H., & Yamamoto, T. (2011) · Epilepsy Research · doi:10.1016/j.eplepsyres.2011.09.007 · Cited by 75 · cited 1×
“EEG is an important tool in epileptic seizure source localization (irritative zone) [11], [12].”
Detection of Spikes with Artificial Neural Networks Using Raw EEG
Özdamar, Ö., & Kalayci, T. (1998) · Computers and Biomedical Research · doi:10.1006/cbmr.1998.1475 · Cited by 74 · cited 4×
“Kalayci and Ozdamar [80] suggested the use of a five-level wavelet transform prior to a neural classifier for epileptic EEG spike detection.”
BackgroundInfluentialIdentification of inter-ictal spikesin the EEGusing neural network analysis
Tarassenko, L., Khan, Y. U., & Holt, M. (1998) · IEE Proceedings - Science Measurement and Technology · doi:10.1049/ip-smt:19982328 · Cited by 72 · cited 2×
“[70] presented a neural-based method for interictal EEG spike detection.”
MethodResultEEG–fMRI in focal epilepsy: Local activation and regional networks
Flanagan, D., Badawy, R. A. B., & Jackson, G. D. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.06.182 · Cited by 71 · cited 1×
“EEG spike detection can be usedwith functional magnetic resonance imaging (fMRI) to localize spike sources in a process called EEG-informed fMRI [22], [23].”
BackgroundGoelz, H., Jones, R. D., & Bones, P. J. (2000) · Clinical Electroencephalography · doi:10.1177/155005940003100406 · Cited by 69 · cited 1×
“[81] presented an automated system for epileptiform-activity detection based on the continuous wavelet transform (CWT).”
MethodA study on fuzzy C-means clustering-based systems in automatic spike detection
İnan, Z. H., & Kuntalp, M. (2006) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2006.10.010 · Cited by 69 · cited 2×
“İnan and Kuntalp [43] presented a two-stage spike detection algorithm implementing a neural pre-classifier in addition to a fuzzy c-means (FCM) clustering algorithm.”
MethodWhitford, G. S. (2014) · Routledge eBooks · doi:10.4324/9781315800998-9 · Cited by 66
Inter-ictal spike detection using a database of smart templates
Lodder, S. S., Askamp, J., & van Putten, M. J. A. M. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.05.019 · Cited by 62 · cited 2×
“[57] presented a template-matching approach for EEG spike detection.”
BackgroundMethodKobayashi, K., Jacobs, J., & Gotman, J. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.03.020 · Cited by 61 · cited 1×
“[73] presented a spike detection method based on time-frequency analysis.”
MethodSpike detection based on a pattern recognition approach using a microcomputer
Oliveira, P., Queiroz, C., & da Silva, F. L. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90011-1 · Cited by 57 · cited 1×
“[32] implemented a spike detection method in a hybrid microcomputer system using a set of features including relative amplitudes, slope, curvature attribute of the spike, and three time durations.”
MethodThe M-Sorter: An automatic and robust spike detection and classification system
Yuan, Y., Yang, C., & Si, J. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.07.012 · Cited by 57
Gaspard, N., Alkawadri, R., Farooque, P., Goncharova, I. I., & Zaveri, H. P. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.10.021 · Cited by 55 · cited 2×
“Inclusion of waveform shape and energy as discrimination factorsmay lead to better results in spike detection as reported in [46], [63], and [70].”
MethodResultToward Online Data Reduction for Portable Electroencephalography Systems in Epilepsy
Casson, A. J., & Rodriguez–Villegas, E. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2027607 · Cited by 53 · cited 7×
“[71] L. Logesparan and E. Rodriguez-Villegas, ‘‘A novel phase congruency based algorithm for online data reduction in ambulatory EEG systems,’’ IEEE Trans.”
MethodInfluentialVisual and Automatic Investigation of Epileptiform Spikes in Intracranial EEG Recordings
Dümpelmann, M., & Elger, C. E. (1999) · Epilepsia · doi:10.1111/j.1528-1157.1999.tb00704.x · Cited by 48 · cited 2×
“[79] M. Dümpelmann and C. Elger, ‘‘Visual and automatic investigation of epileptiform spikes in intracranial EEG recordings,’’ Epilepsia, vol. 40, no. 3, pp. 275–285, 1999.”
BackgroundLoo, C. K., Samraj, A., & Lee, G. C. (2011) · Discrete Dynamics in Nature and Society · doi:10.1155/2011/724697 · Cited by 48 · cited 3×
“Teager, Qian, and SNEO methods are different variants of the simple time domain thresholding techniques that depend on some sorts of difference operators [45]–[47].”
BackgroundMethodZhang, C. H., Sha, Z., Mundahl, J., Liu, S., Lu, Y., Henry, T. R., & He, B. (2015) · NeuroImage Clinical · doi:10.1016/j.nicl.2015.07.014 · Cited by 48 · cited 1×
“EEG spike detection can be usedwith functional magnetic resonance imaging (fMRI) to localize spike sources in a process called EEG-informed fMRI [22], [23].”
BackgroundJi, Z., Sugi, T., Goto, S., Wang, X., Ikeda, A., Nagamine, T., Shibasaki, H., & Nakamura, M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2157917 · Cited by 46 · cited 2×
“is a very strong candidate for EEG and MEG spike detection [57], [59].”
BackgroundMethodAutomatic detection of interictal spikes using data mining models
Valenti, P., Cazamajou, E., Scarpettini, M., Aizemberg, A., Silva, W., & Kochen, S. S. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.06.005 · Cited by 46 · cited 1×
“[67] presented a frequency-domain technique based on data-mining classification for the detection of epileptic EEG spikes utilizing decision trees and statistical Bayesian classifiers.”
MethodWennberg, R. A., & Cheyne, D. O. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.08.032 · Cited by 45 · cited 1×
“Therefore, MEG spike detection is a fundamental step in epileptic seizure source localization [13], [14].”
BackgroundHeers, M., Rampp, S., Kaltenhäuser, M., Pauli, E., Rauch, C., Dölken, M. T., & Stefan, H. (2010) · Seizure · doi:10.1016/j.seizure.2010.06.004 · Cited by 45
Bourien, J., Bellanger, J.-J., Bartoloméi, F., Chauvel, P., & Wendling, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820397 · Cited by 45 · cited 1×
“[50] presented a multi-channel epileptic spike detection method, that depended firstly on filtering the EEG signals to obtain a gamma band from 20 to 80 Hz to reinforce spikes as much as possible.”
MethodEpileptic MEG Spikes Detection Using Common Spatial Patterns and Linear Discriminant Analysis
Khalid, M. I., Alotaiby, T. N., Aldosari, S. A., Alshebeili, S. A., Alhameed, M., Almohammed, F. S. Y., & Al-Otaibi, T. (2016) · IEEE Access · doi:10.1109/access.2016.2602354 · Cited by 44 · cited 1×
“[42] also developed a patient-independent MEG spike detection technique based on common spatial patterns (CSPs) as a feature extractor”
MethodSpike detection approaches for noisy neuronal data: Assessment and comparison
Azami, H., & Sanei, S. (2014) · Neurocomputing · doi:10.1016/j.neucom.2013.12.006 · Cited by 43 · cited 9×
“[46] H. Azami and S. Sanei, ‘‘Spike detection approaches for noisy neuronal data: Assessment and comparison,’’ Neurocomputing, vol. 133, pp. 491–506, Jun. 2014.”
BackgroundMethodResultInfluentialHese, P. V., Martens, J.-P., Waterschoot, L., Boon, P., & Lemahieu, I. A. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2008858 · Cited by 41 · cited 1×
“[72] investigated a frequency-domain spike detection method using the EEG data of genetic absence epilepsy rats of Strasburg.”
MethodRecording human cortical population spikes non-invasively – An EEG tutorial
Waterstraat, G., Fedele, T., Burghoff, M., Scheer, H.-J., & Curio, G. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.08.013 · Cited by 40 · cited 1×
“Scalp EEG signals are recorded non-invasively from the scalp surface using external electrodes, with precautions taken to decrease impedance and enhance conductivity [2].”
Automatic extracellular spike detection with piecewise optimal morphological filter
Liu, X., Yang, X., & Zheng, N. (2011) · Neurocomputing · doi:10.1016/j.neucom.2011.10.016 · Cited by 40 · cited 4×
“s(n), A1, A2, L1, L2, and Z are the neural signal, positive spike amplitude, negative spike amplitude, positive spike duration, negative spike duration, and segment time, respectively, modified from [61].”
BackgroundMethodInfluentialCoutin-Churchman, P. E., Wu, J. Y., Chen, L. L. K., Shattuck, K., Dewar, S., & Nuwer, M. R. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.08.007 · Cited by 40 · cited 1×
“[37] used simple amplitude- and”
Use of discrete Hilbert transformation for automatic spike mapping: A methodological investigation
Witte, H., Eiselt, M., Patáková, I., Petránek, S., Griessbach, G., Krajča, V., & Rother, M. (1991) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446705 · Cited by 38 · cited 1×
“[75] proposed spike detection method that uses the discrete Hilbert transform to extract momentry power and frequency that can be evaluated at each sample.”
MethodPerformance metrics for the accurate characterisation of interictal spike detection algorithms
Casson, A. J., Luna, E., & Rodriguez–Villegas, E. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.10.010 · Cited by 37 · cited 2×
“Unfortunately, this strategy leads to low detection performance [25], [49].”
BackgroundMethodIntracellular currents of interictal penicillin spikes: Evidence from neuromagnetic mapping
Barth, D. S., Sutherling, W. W., & Beatty, J. (1986) · Brain Research · doi:10.1016/0006-8993(86)91040-1 · Cited by 34 · cited 1×
“An important difference between EEG and MEG signals is that the decay rate of the magnetic field is higher than that of the electric field [8]–[10].”
BackgroundPietilä, T., Vapaakoski, S., Nousiainen, U., Värri, A. O., Frey, H., Häkkinen, V., & Neuvo, Y. A. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90134-1 · Cited by 34 · cited 1×
“[74] developed an epileptic activity-recognition method using the adaptive segmentation of EEG signals to extract a set of features including the amplitude average, minimum, and maximum, the segment variability, and the spectral power of five bands.”
MethodNowak, R., Santiuste, M., & Russi, A. (2009) · Seizure · doi:10.1016/j.seizure.2009.07.002 · Cited by 29 · cited 1×
“An MEG spike with its morphological feature’s modified from [28].”
BackgroundDiscrete Lissajous Figures and Applications
Karacor, D., Nazlıbilek, S., Sazlı, M. H., & Akarsu, E. S. (2014) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2014.2318891 · Cited by 29 · cited 1×
“[56] utilized the concept of Lissajous figures and introduced a new concept of rectons for the detection of interictal EEG spikes.”
MethodHerta, J., Koren, J. P., Fürbass, F., Hartmann, M., Kluge, T., Baumgartner, C., & Gruber, A. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.04.064 · Cited by 29 · cited 1×
“[54] and Koren et al.”
Zhang, J., Zou, J., Wang, M., Chen, L., Wang, C., & Wang, G. (2013) · Neurocomputing · doi:10.1016/j.neucom.2012.11.017 · Cited by 28 · cited 2×
“[62] presented a time-domain EEG spike detection method in which they decided whether a segment constituted a spike based on the completeness of the increasing and decreasing trends of a segment.”
BackgroundMethodTanaka, N., Peters, J. M., Prohl, A. K., Takaya, S., Madsen, J. R., Bourgeois, B. F. D., Dworetzky, B. A., Hämäläinen, M., & Stufflebeam, S. M. (2013) · Epilepsy Research · doi:10.1016/j.eplepsyres.2013.11.006 · Cited by 26 · cited 1×
“Source localization is an important presurgical process that is also useful as a postsurgical process to assess the surgical outcome and its effect on seizure activity and strength [17].”
BackgroundEpileptic MEG Spikes Detection Using Amplitude Thresholding and Dynamic Time Warping
Khalid, M. I., Alotaiby, T. N., Aldosari, S. A., Alshebeili, S. A., Alhameed, M., & Poghosyan, V. (2017) · IEEE Access · doi:10.1109/access.2017.2718044 · Cited by 26 · cited 1×
“[58] developed a method for spike detection from multi-channel MEG signals in a patient independent setting.”
MethodSimultaneous spike detection and topographic classification in pediatric surface EEGs
Feucht, M., Hoffmann, K.-P., Steinberger, K., Witte, H., Benninger, F., Arnold, M., & Doering, A. (1997) · Neuroreport · doi:10.1097/00001756-199707070-00021 · Cited by 25 · cited 1×
“[68] introduced an automatic spike detection method using a multilayer perceptron (MLP) and the instantaneous power computed via the Hilbert transform as”
MethodRichard, C., Tanenbaum, A., Audit, B., Arnéodo, A., Khalil, A., & Frankel, W. N. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.12.016 · Cited by 24 · cited 1×
“[78] presented a spike detection algorithm based on the Morlet wavelet transform.”
MethodFürbass, F., Hartmann, M., Halford, J. J., Koren, J. P., Herta, J., Gruber, A., Baumgartner, C., & Kluge, T. (2015) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2015.08.001 · Cited by 23 · cited 1×
“[53] presented a time-domain multi-channel algorithm for the detection of rhythmic and periodic patterns from EEG signals.”
BackgroundKoren, J. P., Herta, J., Draschtak, S., Pötzl, G., Pirker, S., Fürbass, F., Hartmann, M., Kluge, T., & Baumgartner, C. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.04.044 · Cited by 23 · cited 1×
“[55] evaluated the sensitivity and specificity of rhythmic and periodic patterns in continuous EEG (cEEG) signals, recorded in intensive care units, with manually annotated EEG segments.”
BackgroundA simplified arithmetic detector for EEG sharp transients-preliminary results
Qian, J., Barlow, J. S., & Beddoes, M. P. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1331 · Cited by 22 · cited 1×
“Teager, Qian, and SNEO methods are different variants of the simple time domain thresholding techniques that depend on some sorts of difference operators [45]–[47].”
BackgroundRole of Electroencephalography in Presurgical Evaluation of Temporal Lobe Epilepsy
Raghavendra, S., Nooraine, J., & Mirsattari, S. M. (2012) · Epilepsy Research and Treatment · doi:10.1155/2012/204693 · Cited by 20 · cited 1×
“EEG is an important tool in epileptic seizure source localization (irritative zone) [11], [12].”
Itabashi, H., Jin, K., Iwasaki, M., Okumura, E., Kanno, A., Kato, K., Tominaga, T., Kawashima, R., & Nakasato, N. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.02.028 · Cited by 19
A Novel Phase Congruency Based Algorithm for Online Data Reduction in Ambulatory EEG Systems
Logesparan, L., & Rodriguez–Villegas, E. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2160639 · Cited by 16 · cited 1×
“Logesparan and Rodriguez-Villegas spike detection method based on traditional phase congruency, DPC, and MPC, modified from [71].”
MethodFractal dimension analysis for spike detection in low SNR extracellular signals
Salmasi, M., Büttner, U., & Glasauer, S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036004 · Cited by 16 · cited 1×
“The fractal dimension of signals is a statistical measure describing signal similarity over time windows [47], [48].”
BackgroundKakisaka, Y., Wang, Z. I., Mosher, J. C., Nair, D. R., Alexopoulos, A. V., & Burgess, R. C. (2012) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2011.09.019 · Cited by 15 · cited 2×
“Note that epileptic spikes could be seen in MEG or EEG alone, as they have different sensitivities with respect to the location and orientation of epileptic activity [18].”
BackgroundDFAspike: A new computational proposition for efficient recognition of epileptic spike in EEG
Keshri, A. K., Sinha, R. K., Singh, A. P., & Das, B. N. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.05.007 · Cited by 14 · cited 1×
“It is a simple model adopting only the amplitude and slope of EEG signals as the features controlling the state transitions [35].”
MethodUda, T., Tsuyuguchi, N., Okumura, E., Sakamoto, S., Morino, M., Nagata, T., Ikeda, H., Kunihiro, N., Takami, T., & Ohata, K. (2012) · Clinical Neurophysiology · doi:10.1016/j.clinph.2011.12.008 · Cited by 12 · cited 1×
“Methods based on equivalent current dipole (ECD) and standardized low-resolution brain electromagnetic tomography have been used effectively for spike source localization [15].”
MethodThe presence of short and sharp MEG spikes implies focal cortical dysplasia
Ueda, Y., Egawa, K., Ito, T., Takeuchi, F., Nakajima, M., Otsuka, K., Asahina, N., Takahashi, K., Nakane, S., Kohsaka, S., et al. (2015) · Epilepsy Research · doi:10.1016/j.eplepsyres.2015.04.020 · Cited by 5 · cited 1×
“Spike detection fromMEG recordings may be helpful for focal cortical dysplasia (FCD) patients, as it is necessary for epileptic surgeries [16].”
BackgroundDetecting the onset of epileptic seizures
Ferrer, A. R. Z., Maya, L. R., Gonzalez, A. G., Pantaleón, M. A., García, M. C., Nasab, N. M., Valencia, R. H., & Herrera, M. V. (1999) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.765192 · Cited by 5 · cited 2×
“[66] presented a multi-channel spike detection algorithm that depends on processing the EEG signal on a segment-by-segment basis, as shown in Fig.”
MethodMaking waves useful: Improving epileptiform activity recognition using energy criteria
Adjouadi, M., & Ayala, M. (2003) · IEEE Potentials · doi:10.1109/mp.2003.1180932 · Cited by 3 · cited 3×
“They considered each of these attributes as a random variable obeying the Weibull distribution described by [60]”
BackgroundMethodInfluentialMark, D. (2011) · InTech eBooks · doi:10.5772/17244 · Cited by 1 · cited 1×
“To acquire high-resolution EEG signals, a dense array EEG (dEEG) with 256 electrodes is used [4].”
Method
Research works printed but not linked: 3
- 2017, fact sheet
- 2012, 10/20 System Positioning Manual
- okada, 1983, Neurogenesis of evoked magnetic fields, Biomagnetism An Interdisciplinary Approach, 399
Cited by
Virtual brain twins: from basic neuroscience to clinical use
Wang, H., Triebkorn, P., Breyton, M., Dollomaja, B., Lemaréchal, J.-D., Petkoski, S., Sorrentino, P., Depannemaecker, D., Hashemi, M., & Jirsa, V. (2024) · National Science Review · doi:10.1093/nsr/nwae079 · Cited by 195
“For non-invasive epileptogenicity estimation, the spike rate in MEG or EEG can serve as a pertinent data feature [28 ].”
BackgroundNizamis, K., Athanasiou, A., Almpani, S., Dimitrousis, C., & Astaras, A. (2021) · Sensors · doi:10.3390/s21062084 · Cited by 147
“Currently, convo‐ lutional neural networks (CNNs) are considered part of the state‐of‐the‐art among AI models for OC [222].”
BackgroundInfluentialA Brief Introduction to Magnetoencephalography (MEG) and Its Clinical Applications
Fred, A. L., Kumar, S. N., Haridhas, A. K., Ghosh, S., Bhuvana, H. P., Sim, W. K. J., Vijayaragavan, V., Givo, F. A. S., Jousmäki, V., Padmanabhan, P., et al. (2022) · Brain Sciences · doi:10.3390/brainsci12060788 · Cited by 130
“are identified in the time and frequency domain methods [61].”
BackgroundDeep learning for robust detection of interictal epileptiform discharges
Geng, D., Alkhachroum, A. M., Bicchi, M. M., Jagid, J. R., Cajigas, I., & Chen, Z. S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abf28e · Cited by 74
Computer-assisted EEG diagnostic review for idiopathic generalized epilepsy
Clarke, S., Karoly, P. J., Nurse, E., Seneviratne, U., Taylor, J., Knight-Sadler, R., Kerr, R., Moore, B., Hennessy, P., Mendis, D., et al. (2021) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2019.106556 · Cited by 55
Metadata
- Authors
- Abd El-Samie, F. E., Alotaiby, T. N., Khalid, M. I., Alshebeili, S. A., & Aldosari, S. A.
- Affiliations
- King Abdulaziz City for Science and Technology (SA)
- Venue
- IEEE Access
- Published
- 2018
- Volume
- 6
- Pages
- 60673-60688
- ISSN
- 2169-3536 (ISSN-L)
- OpenAlex
- W2896977870
- Cited by
- 82
- References
- 81
- Citations by year
- 2026: 2 · 2025: 7 · 2024: 8 · 2023: 10 · 2022: 16 · 2021: 22 · 2020: 6 · 2019: 11
- FWCI
- 5.81
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- IEEE Access (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- KACST-Lockheed Martin University Funding Program
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Clinical Neurology › Epilepsy research and treatment
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- epileptic spike detection, EEG, magnetoencephalography, epilepsy, seizure detection, seizure prediction, epileptogenic zone localization, automated signal analysis, algorithm classification
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.